Suspended insulin infusion during overnight closed‐loop glucose control in children and adolescents with Type 1 diabetes
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Diabet. Med. 27, 480–484 (2010) Aims We assessed an extended interruption of subcutaneous insulin delivery during overnight closed‐loop glucose control in children and adolescents with Type 1 diabetes (T1D). Methods In seven young subjects with T1D [age 14.2 ± 2.1 years, diabetes duration 6.9 ± 4.0 years, glycated haemoglobin (HbA 1c) 8.0 ± 1.5%, body mass index (BMI) 21.4 ± 4.0 kg/m 2, total daily insulin dose 0.9 ± 0.2 units/kg/day; mean ± sd) participating in overnight closed‐loop glucose control studies, insulin delivery was interrupted for at least 90 min on the basis of predicted hypoglycaemia, low prevailing glucose levels or a too‐steep decline in glucose levels. Results Insulin delivery was interrupted for 165 (105, 210) min [median, interquartile range (IQR)]. Plasma glucose was 6.2 ± 3.2 mmol/l at the time of interruption and 5.5 ± 2.0 mmol/l 105 min later (P = 0.15, paired t‐test). Plasma glucose declined during the first hour of the interruption at a rate of 0.02 ± 0.03 mmol/l per min and reached a nadir of 5.2 ± 2.7 mmol/l; 105 min after the interruption, plasma glucose was increasing at a rate of 0.01 ± 0.03 mmol/l per min. When insulin delivery restarted, plasma glucose was 6.4 ± 2.2 mmol/l and peaked at 7.9 ± 2.1 mmol/l in 60 min (P = 0.01). Physiological levels of plasma insulin were measured throughout with a nadir of 119 ± 78 pmol/l. Conclusions A prolonged interruption of insulin delivery during overnight closed‐loop glucose control to prevent hypoglycaemia was not associated with an increased risk of hyperglycaemia in young people with T1D.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/010 · Cited by 1,274
Self-citationAttia, N., Jones, T. W., Holcombe, J., & Tamborlane, W. V. (1998) · Diabetes Care · doi:10.2337/diacare.21.5.817 · Cited by 98
Zisser, H. (2008) · Diabetes Care · doi:10.2337/dc07-1757 · Cited by 44
Cited by
Closed-loop insulin delivery from bench to clinical practice
Hovorka, R. (2011) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2011.32 · Cited by 342
Self-citationHovorka, R., Kumareswaran, K., Harris, J., Allen, J. M., Elleri, D., Xing, D., Kollman, C., Nodale, M., Murphy, H. R., Dunger, D. B., et al. (2011) · BMJ · doi:10.1136/bmj.d1855 · Cited by 244
“An important feature of our closed loop algorithm is avoidance of hypoglycaemia, which if replicated in the home setting would revolutionise patient safety. The algorithm suspends insulin delivery when the sensor detects a low or rapid fall in glucose levels and does so without increased risk of hyperglycaemia.”
BackgroundSelf-citationISPAD Clinical Practice Consensus Guidelines 2018: diabetes technologies
Sherr, J. L., Tauschmann, M., Battelino, T., de Bock, M., Forlenza, G., Roman, R., Hood, K. K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12731 · Cited by 197
Challenges and recent progress in the development of a closed-loop artificial pancreas
Bequette, B. W. (2012) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2012.09.007 · Cited by 183
“Cengiz et al. (2009) report on pump suspensions that occurred during clinical trials of a PID algorithm, while Elleri et al. (2010) show pump suspension results during trials of a MPC algorithm.”
MethodISPAD Clinical Practice Consensus Guidelines 2022: Diabetes technologies: Insulin delivery
Sherr, J. L., Schoelwer, M., Dos Santos, T. J., Reddy, L., Biester, T., Galderisi, A., van Dyk, J. C., Hilliard, M. E., Berget, C., & DiMeglio, L. A. (2022) · Pediatric Diabetes · doi:10.1111/pedi.13421 · Cited by 152
Metadata
- Authors
- Elleri, D., Allen, J. M., Nodale, M., Wilinska, M. E., Acerini, C. L., Dunger, D. B., & Hovorka, R.
- Venue
- Diabetic Medicine
- Publisher
- Wiley
- Published
- 2010-04
- Volume
- 27
- Issue
- 4
- Pages
- 480-484
- ISSN
- 0742-3071 (ISSN-L)
- 1464-5491
- OpenAlex
- W2021309560
- Cited by
- 37
- References
- 3
- FWCI
- 3.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Suspended insulin infusion during overnight closed‐loop glucose control in children and adolescents with Type 1 diabetes. https://app.cochat.ai/papers/10.1111/j.1464-5491.2010.02964.x
- The paper
- Elleri, D., Allen, J. M., Nodale, M., Wilinska, M. E., Acerini, C. L., Dunger, D. B., & Hovorka, R. (2010). Suspended insulin infusion during overnight closed‐loop glucose control in children and adolescents with Type 1 diabetes. Diabetic Medicine. https://doi.org/10.1111/j.1464-5491.2010.02964.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.