Vibration Control of Structures with Initially Accelerated Passive Tuned Mass Dampers under Near-Fault Earthquake Excitation: Vibration control of structures with initially accelerated PTMDs
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This article deals with the applicability of passive tuned mass damper (PTMD) for reducing the dynamic responses of structures under near-fault earthquake excitations. Three types of pulse-like time functions are employed to simulate the near-fault ground motion. The vibration control effectiveness of PTMDs is extensively investigated through the comparisons of response spectrum and response time histories of a structure with and without PTMDs. To suppress structural peak responses, an initial velocity is applied to the PTMD to accelerate its motion. Numerical studies show that the more cycles of a pulse are contained in the ground motion, the more useful a PTMD becomes in reducing the peak structural responses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mass dampers and their optimal designs for building vibration control
Chang, C. C. (1999) · Engineering Structures · doi:10.1016/s0141-0296(97)00213-7 · Cited by 177
Vibration suppression for high-speed railway bridges using tuned mass dampers
Wang, J. F., Lin, C. C., & Chen, B. L. (2003) · International Journal of Solids and Structures · doi:10.1016/s0020-7683(02)00589-9 · Cited by 173 · cited 2×
“Although previous studies on PTMDs are abundant (Satareh and Hanson, 1992a,b; Gu et al., 1994; Lin et al., 1994, 2001; Chang, 1999; Wang et al., 2003), the vibration control effectiveness of this device has been controversial, especially for seismic applications (Villaverde, 1994; Sadek et al.,…”
ResultSelf-citation
Cited by
Smart structures: Part I—Active and semi-active control
Fisco, N. R., & Adeli, H. (2011) · Scientia Iranica · doi:10.1016/j.scient.2011.05.034 · Cited by 270
“Tuned Mass Dampers (TMD) have fixed frequency and damping characteristics and can be used to tune only a given fixed frequency of vibration, normally the fundamental frequency of vibrations of a structure [32].”
BackgroundWavelet PSO-Based LQR Algorithm for Optimal Structural Control Using Active Tuned Mass Dampers
Amini, F., Hazaveh, N. K., & Rad, A. A. (2013) · Computer-Aided Civil and Infrastructure Engineering · doi:10.1111/mice.12017 · Cited by 137
Active Tendon Control of Torsionally Irregular Structures under Near-Fault Ground Motion Excitation
Nigdeli, S. M., & Boduroğlu, M. H. (2013) · Computer-Aided Civil and Infrastructure Engineering · doi:10.1111/mice.12046 · Cited by 77
A Wavelet‐Based Adaptive Pole Assignment Method for Structural Control
Amini, F., & Samani, M. Z. (2014) · Computer-Aided Civil and Infrastructure Engineering · doi:10.1111/mice.12072 · Cited by 70
“…frequency only and cannot provide protection for a range of frequencies or bandwidth normally found in a strong ground motion for convincing control of the seismic response (Sladek and Klingner, 1983; Lin et al., 2010; Matta, 2012; Cho et al., 2012; Kang et al., 2012; Ghaemmaghami et al., 2013).”
BackgroundHybrid active tuned mass dampers for structures under the ground acceleration
Li, C., & Cao, B. (2015) · Structural Control and Health Monitoring · doi:10.1002/stc.1716 · Cited by 49
Metadata
- Authors
- Lin, C.-C., Chen, C.-L., & Wang, J.-F.
- Venue
- Computer-Aided Civil and Infrastructure Engineering
- Publisher
- Elsevier BV
- Published
- 2010-01
- Volume
- 25
- Issue
- 1
- Pages
- 69-75
- ISSN
- 1093-9687 (ISSN-L)
- 1467-8667
- OpenAlex
- W1911526657
- Cited by
- 46
- References
- 2
- FWCI
- 11.06
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.