Principles of high‐frequency ultrasonography for investigation of skin pathology
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Ultrasonography is a valuable diagnostic tool widely used in medicine. During the last three decades, this non‐invasive skin imaging method has been extended to dermatology. High‐frequency ultrasonography with higher than 20 MHz scanners is well‐established for measuring tumour thickness and skin thickness when treating inflammatory skin diseases such as scleroderma or psoriasis. High‐frequency ultrasonography has become extremely helpful for the preoperative assessment of skin melanoma. The correlation between ultrasonic and histological measurements of melanomas thickness is significantly similarly good using transducers of 20, 75 or 100 MHz frequency (r range from 0.895 to 0.99) and better compared with transducers of 7.5 MHz frequency (r = 0.76). The preoperative sonographically estimated thickness of skin melanoma is sometimes overestimated, because of an underlying inflammatory infiltrate and other reasons. Assessment of skin melanoma thickness using transducers of 100 MHz frequency has better agreement with histology, compared with ultrasonography with 20 MHz transducers. However, the ultrasonic penetration depth is limited to 1.5 mm in case of 100 MHz. The newer ultrasonic techniques such as high‐frequency ultrasonography and colour Doppler sonography could be used for assessment of the tumour vascularization and its metastatic potential. The wide variety of diagnostic information provided by high‐frequency ultrasonography undoubtedly improves the management of oncological and inflammatory skin conditions and underlines its essential position in dermatological practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Srivastava, A., Laidler, P., Davies, R. P., Horgan, K. J., & Hughes, L. E. (1988) · PubMed Central · Cited by 528
Determining Skin Thickness with Pulsed Ultra Sound
Alexander, H., & Miller, D. L. (1979) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12530104 · Cited by 340
Clinical usefulness of variable-frequency ultrasound in localized lesions of the skin
Wortsman, X., & Wortsman, J. (2010) · Journal of the American Academy of Dermatology · doi:10.1016/j.jaad.2009.06.016 · Cited by 302
Assessment of Aging of the Human Skin by In Vivo Ultrasonic Imaging
de Rigal, J., Escoffier, C., Querleux, B., Faivre, B., Agache, P., & Lévêque, J.-L. (1989) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12319741 · Cited by 245
Gniadecka, & Jemec (1998) · British Journal of Dermatology · doi:10.1046/j.1365-2133.1998.02506.x · Cited by 179
Imaging of the skin with 20-MHz US.
Fornage, B. D., McGavran, M. H., Duvic, M., & Waldron, C. A. (1993) · Radiology · doi:10.1148/radiology.189.1.8372222 · Cited by 176
Moore, T. L. (2003) · Rheumatology · doi:10.1093/rheumatology/keg435 · Cited by 164
Ultrasound Scanning in Dermatology
Schmid-Wendtner, M.-H., & Burgdorf, W. H. C. (2005) · Archives of Dermatology · doi:10.1001/archderm.141.2.217 · Cited by 157
Breitbart, E. W., Grove, G. L., Miki, Y., Murakami, S., & Brockmann, W.-P. (1988) · Springer eBooks · doi:10.1007/978-3-642-83360-1_106 · Cited by 150
Agache, P. G., & Humbert, P. G. (2004) · Springer eBooks · doi:10.1007/978-3-662-08585-1 · Cited by 148
Humbert, P. G., Maibach, H. I., Fanian, F., & Agache, P. G. (2011) · Medical Entomology and Zoology · Cited by 139
Value of high-frequency US for preoperative assessment of skin tumors.
Lassau, N., Spatz, A., Avril, M.-F., Tardivon, A. A., Margulis, A., Mamelle, G., Vanel, D., & Leclère, J. (1997) · Radiographics · doi:10.1148/radiographics.17.6.9397463 · Cited by 130
Ultrasound in dermatology. Part I. High frequency ultrasound.
Jemec, G. B. E., Gniadecka, M., & Ulrich, J. (2000) · European Journal of Dermatology · Cited by 114
Ultrasound in dermatology - basic principles and applications
Rallan, D., & Harland, C. C. (2003) · Clinical and Experimental Dermatology · doi:10.1046/j.1365-2230.2003.01405.x · Cited by 105
Melanoma histological Breslow thickness predicted by 75-MHz ultrasonography
Guitera, P., Li, L. X., Crotty, K. A., FitzGerald, P., Mellenbergh, R., Pellacani, G., & Menzies, S. W. (2008) · British Journal of Dermatology · doi:10.1111/j.1365-2133.2008.08681.x · Cited by 104
Machet, L., Belot, V., Naouri, M., Boka, M., Mourtada, Y., Giraudeau, B., Laure, B., Perrinaud, A., Machet, M., & Vaillant, L. (2009) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2009.03.018 · Cited by 98
Influence of body water distribution on skin thickness: measurements using high-frequency ultrasound
Eisenbeiss, C., Welzel, J., Eichler, W., & Klotz, K.-F. (2001) · British Journal of Dermatology · doi:10.1046/j.1365-2133.2001.04180.x · Cited by 91
Desai, T., Desai, A., HOROWITZ, D. C., Kartono, F., & WAHL, T. (2007) · Dermatologic Surgery · doi:10.1111/j.1524-4725.2007.33257.x · Cited by 78
Tacke, J., Haagen, G., Hornstein, O. P., Huettinger, G., Kiesewetter, F., SCHELL, H., & Diepgen, T. L. (2006) · British Journal of Dermatology · doi:10.1111/j.1365-2133.1995.tb05015.x · Cited by 77
Pellacani, G., & Seidenari, S. (2003) · Archives of Dermatology · doi:10.1001/archderm.139.3.293 · Cited by 74
Serup, J. V. (1984) · Acta Dermato Venereologica · doi:10.2340/0001555564214219 · Cited by 73
Krähn, G. M., Gottlöber, P., Sander, C. A., & Peter, R. U. (1998) · Pigment Cell Research · doi:10.1111/j.1600-0749.1998.tb00725.x · Cited by 57
Moore, J. V., & Allan, E. (2003) · British Journal of Dermatology · doi:10.1111/j.1365-2133.2003.05558.x · Cited by 48
Gniadecka, M. (1995) · Acta Dermato Venereologica · doi:10.2340/0001555575120124 · Cited by 47
Assessment of actinic skin damage by 20-MHz sonography.
Hoffmann, K. K. P., Tp, D., Stücker, M., el-Gammal, S., & Altmeyer, P. (1994) · PubMed · Cited by 43
Rallan, D., Dickson, M., Bush, N. L., Harland, C. C., Mortimer, P. S., & Bamber, J. C. (2006) · Skin Research and Technology · doi:10.1111/j.0909-725x.2006.00136.x · Cited by 21
Cited by
Common Applications of Dermatologic Sonography
Wortsman, X. (2012) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2012.31.1.97 · Cited by 270
Metadata
- Authors
- Jasaitiene, D., Valiukeviciene, S., Linkeviciute, G., Raisutis, R., Jasiuniene, E., & Kazys, R.
- Venue
- Journal of the European Academy of Dermatology and Venereology
- Publisher
- Wiley
- Published
- 2010-09-16
- Volume
- 25
- Issue
- 4
- Pages
- 375-382
- ISSN
- 0926-9959 (ISSN-L)
- 1468-3083
- OpenAlex
- W2159100755
- Cited by
- 194
- References
- 28
- FWCI
- 3.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.