Lymph flow dynamics in exercising human skeletal muscle as detected by scintography
Open accessThe DOI matches its Crossref record.
Abstract
The effects of dynamic and isometric muscle contractions on the lymph flow dynamics in human skeletal muscle were studied with a scintographic method. Radioactively labelled human serum albumin (99m Tc‐HSA) was injected bilaterally into the vastus lateralis muscles of eight men (n= 16), four of whom had had an endurance training background. The subjects performed 100 submaximal contractions in 10 min as (i) dynamic knee extensions (CONS), (ii) isometric contractions with the knees at full extension (IMExt), or (iii) isometric contractions with knees fixed at 90 deg angle flexion (IMFlex). The exercises were separated by 65 min periods in supine rest. The level of radioactivity at the injection site was monitored by a gamma‐camera, and the clearance rate of radioactivity (CR) was calculated as the fractional decrease during the periods of interest (CR unit =% min−). The clearance rate was low during the rest periods (0.04 ± 0.05% min−1), though higher in the trained than in the sedentary subjects (0.06 ± 0.05 vs. 0.03 ± 0.03% min−1; P= 0.008). Exercise increased the clearance rate three‐ to sixfold, to 0.16 ± 0.16% min−1 during CONS, 0.20 ± 0.15% min− during IMExt and 0.09 ± 0.11 % min−1 during IMFlex. There were no differences between the subject subgroups. The higher clearance rate during IMExt than during IMFlex (P= 0.02) demonstrates the importance of muscle deformations on lymph propulsion and experimentally confirms the current concepts of lymph formation and propulsion in voluntarily active skeletal muscle. It is suggested that lymph propulsion by working muscle is most efficient when the muscle is able to shorten close to its minimum length.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lymphatic Vessel Network Structure and Physiology
Breslin, J. W., Yang, Y., Scallan, J. P., Sweat, R. S., Adderley, S. P., & Murfee, W. L. (2018) · Comprehensive Physiology · doi:10.1002/cphy.c180015 · Cited by 341
Lymph Flow, Shear Stress, and Lymphocyte Velocity in Rat Mesenteric Prenodal Lymphatics
DIXON, J. B., GREINER, S. T., GASHEV, A. A., COTE, G. L., MOORE, J. E., & ZAWIEJA, D. C. (2006) · Microcirculation · doi:10.1080/10739680600893909 · Cited by 267
Second-generation minimal physiologically-based pharmacokinetic model for monoclonal antibodies
Cao, Y., Balthasar, J. P., & Jusko, W. J. (2013) · Journal of Pharmacokinetics and Pharmacodynamics · doi:10.1007/s10928-013-9332-2 · Cited by 161
Potential Sources of Inter-Subject Variability in Monoclonal Antibody Pharmacokinetics
Gill, K. L., Machavaram, K. K., Rose, R. H., & Chetty, M. (2016) · Clinical Pharmacokinetics · doi:10.1007/s40262-015-0361-4 · Cited by 82
“Exercise, heating and rubbing also increase the local lymph flow rate [41, 42].”
Kivelä, R., Kyröläinen, H., Selänne, H., Komi, P. V., Kainulainen, H., & Vihko, V. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00531.2007 · Cited by 66
“We also hypothesized that exercise may promote proliferation of lymphatic vessels (lymphangiogenesis) analogous to angiogenesis, because skeletal muscle lymph flow has been shown to increase during both isometric and dynamic muscle contractions (14).”
Self-citation
Metadata
- Authors
- Havas, E., Parviainen, T., Vuorela, J., Toivanen, J., Nikula, T., & Vihko, V.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1997-10
- Volume
- 504
- Issue
- 1
- Pages
- 233-239
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2063360073
- Cited by
- 113
- References
- 0
- FWCI
- 0.84
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Lymph flow dynamics in exercising human skeletal muscle as detected by scintography. https://app.cochat.ai/papers/10.1111/j.1469-7793.1997.233bf.x
- The paper
- Havas, E., Parviainen, T., Vuorela, J., Toivanen, J., Nikula, T., & Vihko, V. (1997). Lymph flow dynamics in exercising human skeletal muscle as detected by scintography. The Journal of Physiology. https://doi.org/10.1111/j.1469-7793.1997.233bf.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.