Relationship Between Venous Pressure and tissue Volume During Venous Congestion Plethysmography in Man
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Venous congestion strain‐gauge plethysmography enables the non‐invasive assessment of arterial blood flow, fluid filtration capacity (Kf), venous pressure (Pv)and isovolumetric venous pressure (Pvi)in man. One of the major assumptions of this technique, that cuff pressure (Peuff) applied to the limb equals Pv at the level of the strain gauge, was tested in this study. In nine healthy male volunteers (mean age, 29.3 ± 1.2 years) the saphenous vein was cannulated with an 18‐gauge catheter proximal to the medial malleolus. The subjects were supine and Pv was continuously measured during the application of small step (8–10 mmHg) increases in congestion Pcuff (up to 70 mm Hg). Pcuff, changes in limb circumference and Pv were recorded by computer for off‐line analysis. Since the determination of Pv is influenced by the changes in plasma oncotic pressure, venous blood samples were obtained at the start of the study, when P& was raised to 30 mmHg and again to 65 mmHg and 4 min after deflation of the cuff. The relationship between Pv and Pcuff was linear over the range of 10–70 mm Hg (n= 9, 69 measurements, slope 0.9.1, r= 0.97, P. <<0.001). The non‐invasively measured calf Pv based on the intercept of the relationship between the vascular compliance component (Vv) and Pcuff, was 8.0±0.4mmHg, which was not significantly different from the corrected invasively measured Pv value of 8.8±0.3 mmHg P= 0.08). Venous blood lactate and haemoglobin concentrations, as well as colloid osmotic pressure, total protein and albumin concentrations were unchanged throughout the protocol, whereas significant decreases in Po2 and blood glucose concentration were observed when Pcuff reached 65 mmHg. Assuming a constant oxygen consumption, this may suggest a reduction in tissue perfusion. This study demonstrates the close correlation between Pcuff and Pv in the saphenous vein. Since the small congestion Pcuff step protocol does not cause significant increase in plasma oncotic pressure, we conclude that Pv as well as Kf can be accurately determined with this venous congestion plethysmography protocol.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The measurement of volume changes in human limbs
Whitney, R. J. (1953) · The Journal of Physiology · doi:10.1113/jphysiol.1953.sp004926 · Cited by 1,489 · cited 1×
“Venous congestion strain-gauge plethysmography (VCP) was first introduced by Whitney for the non-invasive assessment of arterial blood flow in man (Whitney, 1953).”
MethodInterstitial-lymphatic mechanisms in the control of extracellular fluid volume
Aukland, K., & Reed, R. K. (1993) · Physiological Reviews · doi:10.1152/physrev.1993.73.1.1 · Cited by 934 · cited 3×
“The resulting increase in fractional extraction of plasma water would alter the plasma protein concentration at the microvascular interface and thus limit fluid filtration (Aukland & Reed, 1993).”
BackgroundInfluentialMellander, S., ÖBerg, B., & Odelram, H. (1964) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1964.tb02940.x · Cited by 156
Gamble, J., Gartside, I. B., & Christ, F. (1993) · The Journal of Physiology · doi:10.1113/jphysiol.1993.sp019642 · Cited by 135 · cited 8×
“Kf is determined from the relationship between fluid filtration and the applied Pcuff (Gamble et al. 1993).”
BackgroundMethodSelf-citationDeep venous contribution to hydrostatic blood volume change in the human leg
Buckey, J. C., Peshock, R. M., & Blomqvist, C. G. (1988) · The American Journal of Cardiology · doi:10.1016/0002-9149(88)90976-9 · Cited by 86
Youmans, J. B., Wells, H. S., Donley, D., Miller, D. G., & Frank, H. (1934) · Journal of Clinical Investigation · doi:10.1172/jci100597 · Cited by 83 · cited 1×
“…observations we believe that the values given here represent a good estimate of superficial and deep Pv. Discussion of the blood sample data Youmans et al. (1934), Noddeland et al. (1981) and Rayman et al. (1994) reported an increase in plasma oncotic pressure of venous blood draining from…”
BackgroundGamble, J., Christ, F., & Gartside, I. B. (1997) · The Journal of Physiology · doi:10.1113/jphysiol.1997.sp021880 · Cited by 53
Self-citationDuration of increase in vascular volume during venous stasis
Sejrsen, P., Henriksen, O. B., Paaske, W. P., & Nielsen, S. L. (1981) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1981.tb06739.x · Cited by 44
Filling and emptying of the low-pressure blood vessels of the human forearm.
Brown, E., Greenfield, D., Goei, J. S., & Plassaras, G. C. (1966) · Journal of Applied Physiology · doi:10.1152/jappl.1966.21.2.573 · Cited by 44 · cited 3×
“If one allows for this time span, then the value obtained for different venous cannulation sites varied by only 1—2 mmHg (Brown et al. 1966).”
BackgroundInfluentialSkeletal muscle oxygenation monitoring by near infrared spectroscopy.
Blasi, R. A. D., Quaglia, E., & Ferrari, M. (1991) · PubMed · Cited by 29
The Measurement of Fluid Filtration in Human Limbs
Michel, C. C., & Moyses, C. (1987) · Developments in cardiovascular medicine · doi:10.1007/978-1-4613-2335-8_7 · Cited by 26 · cited 1×
“This method also enables the non-invasive determination of fluid filtration capacity (Kf), venous pressure (Pv) and isovolumetric venous pressure (Pvi), the cuff pressure which has to be exceeded to induce net fluid filtration (Mellander, Oberg & Odelram, 1964; Michel & Moyses, 1987).”
MethodA study of factors governing fluid filtration in the diabetic foot
Rayman, G. A., WILLIAMS, S. A., Gamble, J., & Tooke, J. E. (1994) · European Journal of Clinical Investigation · doi:10.1111/j.1365-2362.1994.tb02027.x · Cited by 23 · cited 1×
“…that the values given here represent a good estimate of superficial and deep Pv. Discussion of the blood sample data Youmans et al. (1934), Noddeland et al. (1981) and Rayman et al. (1994) reported an increase in plasma oncotic pressure of venous blood draining from the foot during dependency.”
BackgroundSelf-citation
Cited by
Neurophysiological and Computational Principles of Cortical Rhythms in Cognition
Wang, X.-J. (2010) · Physiological Reviews · doi:10.1152/physrev.00035.2008 · Cited by 1,939
Role of Endogenous Cannabinoids in Synaptic Signaling
FREUND, T. F., KATONA, I., & PIOMELLI, D. (2003) · Physiological Reviews · doi:10.1152/physrev.00004.2003 · Cited by 1,574
Hippocampal GABAergic Inhibitory Interneurons
Pelkey, K. A., Chittajallu, R., Craig, M. T., Tricoire, L., Wester, J. C., & McBain, C. J. (2017) · Physiological Reviews · doi:10.1152/physrev.00007.2017 · Cited by 889
Cellular and Synaptic Adaptations Mediating Opioid Dependence
Williams, J. T., Christie, M. J., & Manzoni, O. (2001) · Physiological Reviews · doi:10.1152/physrev.2001.81.1.299 · Cited by 848
Cellular Distribution and Functions of P2 Receptor Subtypes in Different Systems
Burnstock, G., & Knight, G. E. (2004) · International Review of Cytology · doi:10.1016/s0074-7696(04)40002-3 · Cited by 795
Metadata
- Authors
- Christ, F., Gamble, J., Baschnegger, H., & Gartside, I. B.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1997-09
- Volume
- 503
- Issue
- 2
- Pages
- 463-467
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2150712840
- Cited by
- 182
- References
- 12
- FWCI
- 11.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.