CoChat

Effect of hypoxia on the hypopnoeic and apnoeic threshold for CO2 in sleeping humans

Open access
Xie, Ailiang, Skatrud, James B., Dempsey, Jerome A. · 2001 · The Journal of Physiology
Cited by 96

The DOI matches its Crossref record.

Abstract

1. Rhythmic breathing during sleep requires that P(CO2) be maintained above a sensitive hypocapnic apnoeic threshold. Hypoxia causes periodic breathing during sleep that can be prevented or eliminated with supplemental CO(2). The purpose of this study was to determine the effect of hypoxia in changing the difference between the eupnoeic P(CO2) and the P(CO2) required to produce hypopnoea or apnoea (hypopnoea/apnoeic threshold) in sleeping humans. 2. The effect of hypoxia on eupnoeic end-tidal partial pressure of CO(2) (P(ET,CO2)) and hypopnoea/apnoeic threshold P(ET,CO2) was examined in seven healthy, sleeping human subjects. A bilevel pressure support ventilator in a spontaneous mode was used to reduce P(ET,CO2) in small decrements by increasing the inspiratory pressure level by 2 cmH2O every 2 min until hypopnoea (failure to trigger the ventilator) or apnoea (no breathing effort) occurred. Multiple trials were performed during both normoxia and hypoxia (arterial O(2) saturation, S(a,O2) = 80 %) in a random order. The hypopnoea/apnoeic threshold was determined by averaging P(ET,CO2) of the last three breaths prior to each hypopnoea or apnoea. 3. Hypopnoeas and apnoeas were induced in all subjects during both normoxia and hypoxia. Hypoxia reduced the eupnoeic P(ET,CO2) compared to normoxia (42.4 +/- 1.3 vs. 45.0 +/- 1.1 mmHg, P < 0.001). However, no change was observed in either the hypopnoeic threshold P(ET,CO2) (42.1 +/- 1.4 vs. 43.0 +/- 1.2 mmHg, P > 0.05) or the apnoeic threshold P(ET,CO2) (41.3 +/- 1.2 vs. 41.6 +/- 1.0 mmHg, P > 0.05). Thus, the difference in P(ET,CO2) between the eupnoeic and threshold levels was much smaller during hypoxia than during normoxia (-0.2 +/- 0.2 vs. -2.0 +/- 0.3 mmHg, P < 0.01 for the hypopnoea threshold and -1.1 +/- 0.2 vs. -3.4 +/- 0.3 mmHg, P < 0.01 for the apnoeic threshold). We concluded that hypoxia causes a narrowing of the difference between the baseline P(ET,CO2) and the hypopnoea/apnoeic threshold P(ET,CO2), which could increase the likelihood of ventilatory instability.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1469-7793.2001.00269.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 96

Metadata

Authors
Xie, A., Skatrud, J. B., & Dempsey, J. A.
Venue
The Journal of Physiology
Publisher
Wiley
Published
2001-08
Volume
535
Issue
1
Pages
269-278
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2040620978
Cited by
96
References
0
FWCI
1.59
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of hypoxia on the hypopnoeic and apnoeic threshold for CO2 in sleeping humans. https://app.cochat.ai/papers/10.1111/j.1469-7793.2001.00269.x
The paper
Xie, A., Skatrud, J. B., & Dempsey, J. A. (2001). Effect of hypoxia on the hypopnoeic and apnoeic threshold for CO2 in sleeping humans. The Journal of Physiology. https://doi.org/10.1111/j.1469-7793.2001.00269.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.