Relationships ol Pulse Transmission Times to Pre‐ejection Period and Blood Pressure
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This research addressed the question of whether pulse transmission time to the ear (E‐PTT) serves as a satisfactory estimate of pre‐ejcction period (PEP) and whether the intracardiac or arterial components of pulse transmission times are correlated with hlood pressure. A median correlation of .86 was found for within‐suhject correlations between E‐PTT and PEP, and a correlation of .97 was found on trial means across subjects. Pulse transmission times to the ear and finger (measured from the Q‐wave) were substantially correlated with systolic but not diastolic blood pressure. PEP, the intracardiac component of pulse transmission time, was moderately correlated with systolic blood pressure, but the arterial components were not. It was concluded that E‐PIT estimates PEP in within‐subject comparisons, and that the association of the pulse transmission times with systolic blood pressure is by virtue of the fact that these intervals encompass PEP rather than the arterial components. It was further concluded that pulse transmission times more directly reflect sympathetic cardiac influences than they do blood pressure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pre‐ejection Period: Measuring Beta‐adrenergic Influences Upon the Heart
Newlin, D. B., & Levenson, R. W. (1979) · Psychophysiology · doi:10.1111/j.1469-8986.1979.tb01519.x · Cited by 275
Self-citation
Cited by
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
Gottman, J. M., Jacobson, N. S., Rushe, R. H., & Shortt, J. W. (1995) · Journal of Family Psychology · doi:10.1037/0893-3200.9.3.227 · Cited by 363
Relationships between features of autonomic cardiovascular control and cognitive performance
Duschek, S., Muckenthaler, M., Werner, N., & Reyes del Paso, G. A. (2009) · Biological Psychology · doi:10.1016/j.biopsycho.2009.03.003 · Cited by 249
Wong, M. Y.-M., Poon, C. C.-Y., & Zhang, Y.-T. (2009) · Cardiovascular Engineering · doi:10.1007/s10558-009-9070-7 · Cited by 191
“Pulse transit time (PTT), or known as the inverse of pulse wave velocity, has been demonstrated as one of the potential parameters for a cuffless and non-invasive BP measurement (Newlin 1981; Allen et al. 1981; Lane et al. 1983; Pollak and Obrist 1983; Poon and Zhang 2005).”
BackgroundA Novel Continuous Blood Pressure Estimation Approach Based on Data Mining Techniques
Miao, F., Fu, N., Zhang, Y.-T., Ding, X.-R., Hong, X., He, Q., & Li, Y. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2691715 · Cited by 174
Metadata
- Authors
- Newlin, D. B.
- Venue
- Psychophysiology
- Publisher
- Wiley
- Published
- 1981-05
- Volume
- 18
- Issue
- 3
- Pages
- 316-321
- ISSN
- 0048-5772 (ISSN-L)
- 1469-8986
- OpenAlex
- W2049176868
- Cited by
- 89
- References
- 1
- FWCI
- 3.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Relationships ol Pulse Transmission Times to Pre‐ejection Period and Blood Pressure. https://app.cochat.ai/papers/10.1111/j.1469-8986.1981.tb03042.x
- The paper
- Newlin, D. B. (1981). Relationships ol Pulse Transmission Times to Pre‐ejection Period and Blood Pressure. Psychophysiology. https://doi.org/10.1111/j.1469-8986.1981.tb03042.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.