The Correction of EOG Artifacts by Frequency Dependent and Frequency Independent Methods
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Methods for correcting EEG which is contaminated by EOG artifacts, which are frequency dependent or frequency independent, were compared. EEG activity contaminated mainly by eye movements was treated separately from activity contaminated mainly by blinks. The statistical comparison was based on representative, real data incorporating differential effects over frequency. The influence of EOG activity on different derivations and bands, and the resulting need for correction of EOG artifacts were of interest too. Correction using a constant gain function proved to be consistently inferior to using a gain depending on frequency. For eye movements, differences were, however, not very large in practical terms, and this was true for all frequency bands. The correction of blinks by the time domain method (i.e., constant gain) may become misleading in the sub‐delta band, which might have implications for very slow activity such as slow cortical potentials. Transfer functions not corrected for coherent EEG activity at the EOG electrodes overcompensated in the alpha and beta bands, in line with earlier results showing the need to incorporate coherent EEG activity into the determination of EOG‐EEG transfer. It was found to be preferable to use sample average coefficients and gain functions, rather than individual ones, leading also to simpler computing. EOG correction is indispensable at frontal derivations, in particular for the delta and theta bands. It is advisable to correct at central and even at parietal derivations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new method for off-line removal of ocular artifact
Gratton, G., Coles, M. G. H., & Donchin, E. (1983) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(83)90135-9 · Cited by 5,055
Cited by
Approach^withdrawal and cerebral asymmetry: Emotional expression and brain physiology: I.
Davidson, R. J., Ekman, P., Saron, C. D., & Senulis, J. A. (1990) · Journal of Personality and Social Psychology · doi:10.1037//0022-3514.58.2.330 · Cited by 1,637
Removal of ocular artifact from the EEG: a review
Croft, R. J., & Barry, R. J. (2000) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/s0987-7053(00)00055-1 · Cited by 756
Henriques, J. B., & Davidson, R. J. (1990) · Journal of Abnormal Psychology · doi:10.1037//0021-843x.99.1.22 · Cited by 635
The phi complex as a neuromarker of human social coordination
Tognoli, E., Lagarde, J., DeGuzman, G. C., & Kelso, J. A. S. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0611453104 · Cited by 437
Development of the EEG of school-age children and adolescents. I. Analysis of band power
Gasser, T., Verleger, R., Bächer, P., & Sroka, L. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90204-0 · Cited by 389
Self-citationClinical application of the P300 event-related brain potential
Polich, J. (2004) · Physical Medicine and Rehabilitation Clinics of North America · doi:10.1016/s1047-9651(03)00109-8 · Cited by 366
P300 Clinical Utility and Control of Variability
Polich, J. (1998) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199801000-00004 · Cited by 342
Beta power in the EEG of alcoholics
Rangaswamy, M., Porjesz, B., Chorlian, D. B., Wang, K., Jones, K. A., Bauer, L. O., Rohrbaugh, J., O’Connor, S. J., Kuperman, S., Reich, T., et al. (2002) · Biological Psychiatry · doi:10.1016/s0006-3223(02)01362-8 · Cited by 340
Linkage disequilibrium between the beta frequency of the human EEG and a GABA A receptor gene locus
Porjesz, B., Almasy, L., Edenberg, H. J., Wang, K., Chorlian, D. B., Foroud, T., Goate, A., Rice, J. P., O'Connor, S. J., Rohrbaugh, J., et al. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.052716399 · Cited by 311
Moretti, D. (2003) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(02)00153-8 · Cited by 253
Davidson, R. J., Chapman, J. P., Chapman, L. J., & Henriques, J. B. (1990) · Psychophysiology · doi:10.1111/j.1469-8986.1990.tb01970.x · Cited by 250
P300 in Clinical Applications: Meaning, Method, and Measurement
Polich, J. (1991) · American Journal of EEG Technology · doi:10.1080/00029238.1991.11080373 · Cited by 217
Dipole models of eye movements and blinks
Berg, P., & Scherg, M. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90154-v · Cited by 200
Resting EEG in first‐episode and chronic schizophrenia
SPONHEIM, S. R., CLEMENTZ, B. A., IACONO, W. G., & BEISER, M. (1994) · Psychophysiology · doi:10.1111/j.1469-8986.1994.tb01023.x · Cited by 189
The effects of ocular artifacts on (lateralized) broadband power in the EEG
Hagemann, D., & Naumann, E. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00541-1 · Cited by 165
Development of the EEG of school-age children and adolescents II. Topography
Gasser, T., Jennen-Steinmetz, C., Sroka, L., Verleger, R., & Möcks, J. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90205-2 · Cited by 165
“A correction for EOG artifacts was performed for all derivations, except for Pz, O1, 02 (Gasser et al. 1985, 1986).”
MethodSelf-citationArtifact Processing in Computerized Analysis of Sleep EEG – A Review
Anderer, P., Roberts, S., Schlögl, A., Gruber, G., Klösch, G., Herrmann, W., Rappelsberger, P., Filz, O., Barbanoj, M. J., Dorffner, G., et al. (1999) · Neuropsychobiology · doi:10.1159/000026613 · Cited by 161
“Thus, the interference of the artifact in the EEG channel is determined, for example, by means of regression analysis in time [22] or frequency domain [23].”
MethodDealing with artifacts: The EOG contamination of the event-related brain potential
Gratton, G. (1998) · Behavior Research Methods, Instruments, & Computers · doi:10.3758/bf03209415 · Cited by 142
“Further, whereas Gasser et al. (1986) re ported a small delay (a few milliseconds) in the peak of EOG activity across electrodes, this was not replicated in subsequent work (see Berg, 1989; van den Berg-Lenssen, Brunia, & 810m, 1989).”
MethodResultBashivan, P., Bidelman, G. M., & Yeasin, M. (2014) · European Journal of Neuroscience · doi:10.1111/ejn.12749 · Cited by 91
“…on EEG recordings are most prevalent in prefrontal scalp locations and within lower frequency bands (i.e., delta and theta bands) (Hagemann & Naumann, 2001); EOG power is negligible at higher frequencies of the EEG where we observe our WM effects (i.e., a- and b-bands; Gasser et al., 1985, 1986).”
Background
Metadata
- Authors
- Gasser, T., Sroka, L., & Möcks, J.
- Venue
- Psychophysiology
- Publisher
- Wiley
- Published
- 1986-11
- Volume
- 23
- Issue
- 6
- Pages
- 704-712
- ISSN
- 0048-5772 (ISSN-L)
- 1469-8986
- OpenAlex
- W2072377519
- Cited by
- 84
- References
- 1
- FWCI
- 1.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.