The effects of electrode impedance on data quality and statistical significance in ERP recordings
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
To determine whether data quality is meaningfully reduced by high electrode impedance, EEG was recorded simultaneously from low- and high-impedance electrode sites during an oddball task. Low-frequency noise was found to be increased at high-impedance sites relative to low-impedance sites, especially when the recording environment was warm and humid. The increased noise at the high-impedance sites caused an increase in the number of trials needed to obtain statistical significance in analyses of P3 amplitude, but this could be partially mitigated by high-pass filtering and artifact rejection. High electrode impedance did not reduce statistical power for the N1 wave unless the recording environment was warm and humid. Thus, high electrode impedance may increase noise and decrease statistical power under some conditions, but these effects can be reduced by using a cool and dry recording environment and appropriate signal processing methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371 · cited 2×
“All simulations were conducted inMatlab (The Mathworks, Inc., Natick, MA) using the EEGLAB Toolbox (Delorme & Makeig, 2004) and custom routines.”
Method(2005) · Cited by 5,977
(2001) · doi:10.1017/cbo9780511546396 · Cited by 4,482
Picton, T. W., Bentin, S., Berg, P., Donchin, E., Hillyard, S. A., Johnson, R., Miller, G. A., Ritter, W., Ruchkin, D. S., Rugg, M. D., et al. (2000) · Psychophysiology · doi:10.1111/1469-8986.3720127 · Cited by 2,157
Scalp electrode impedance, infection risk, and EEG data quality
Ferree, T. C., Luu, P., Russell, G. S., & Tucker, D. M. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00533-2 · Cited by 1,005
Spatial sampling of head electrical fields: the geodesic sensor net
Tucker, D. M. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90121-b · Cited by 751
Metting van Rijn, A. C., Peper, A., & Grimbergen, C. A. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441666 · Cited by 450
High-quality recording of bioelectric events: Part 1 Interference reduction, theory and practice
Metting van Rijn, A. C., Peper, A., & Grimbergen, C. A. (1990) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441961 · Cited by 427
Distortion of ERP averages due to overlap from temporally adjacent ERPs: Analysis and correction
WOLDORFF, M. G. (1993) · Psychophysiology · doi:10.1111/j.1469-8986.1993.tb03209.x · Cited by 384
Decomposing skin conductance into tonic and phasic components
Lim, C. L., Rennie, C., Barry, R. J., Bahramali, H., Lazzaro, I., Manor, B., & Gordon, E. (1997) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(96)00713-1 · Cited by 226
Cephalic skin potentials in electroencephalography
Picton, T. W., & Hillyard, S. A. (1972) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(72)90122-8 · Cited by 156 · cited 3×
“Picton and Hillyard (1972) note that puncturing the skin with a needle at the recording site is the most effective means of eliminating skin potentials; gentle abrasion of the skin also appears to be quite effective at minimizing skin potentials and can be accomplishedwith little or no discomfort…”
BackgroundElectrical activity of the skin : Its measurement and uses in psychophysiology
Edelberg, R. (1972) · Medical Entomology and Zoology · Cited by 145
The Time Constant in P300 Recording
Duncan‐Johnson, C. C., & Donchin, E. (1979) · Psychophysiology · doi:10.1111/j.1469-8986.1979.tb01440.x · Cited by 103
Johnson, M. H., de Haan, M., Oliver, A., Smith, W., Hatzakis, H., Tucker, L. A., & Csibra, G. (2001) · Developmental Neuropsychology · doi:10.1207/s15326942dn1903_4 · Cited by 78
Gibson, T. (2017) · Thieme Medical and Scientific Publishers Private Limited eBooks · doi:10.1055/b-0042-186285 · Cited by 69
Prevalence and Methods of Control of the Cephalic Skin Potential EEG Artifact
Corby, J. C., Roth, W. T., & Kopell, B. S. (1974) · Psychophysiology · doi:10.1111/j.1469-8986.1974.tb00554.x · Cited by 34
THE REDUCTION OF PALMAR SKIN POTENTIAL BY EPIDERMAL HYDRATION
Fowles, D. C., & Venables, P. H. (1970) · Psychophysiology · doi:10.1111/j.1469-8986.1970.tb02231.x · Cited by 26
Cited by
ERPLAB: an open-source toolbox for the analysis of event-related potentials
Lopez-Calderon, J., & Luck, S. J. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00213 · Cited by 2,584
Self-citationSurface Electromyography Signal Processing and Classification Techniques
Chowdhury, R., Reaz, M., Ali, M., Bakar, A., Chellappan, K., & Chang, T. (2013) · Sensors · doi:10.3390/s130912431 · Cited by 1,000
Digital filter design for electrophysiological data – a practical approach
Widmann, A., Schröger, E., & Maess, B. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.08.002 · Cited by 711
Keil, A., Debener, S., Gratton, G., Junghöfer, M., Kappenman, E. S., Luck, S. J., Luu, P., Miller, G. A., & Yee, C. M. (2014) · Psychophysiology · doi:10.1111/psyp.12147 · Cited by 699
Self-citationPreparations, Properties, and Applications of Polyaniline and Polyaniline Thin Films—A Review
Beygisangchin, M., Abdul Rashid, S., Shafie, S., Sadrolhosseini, A. R., & Lim, H. N. (2021) · Polymers · doi:10.3390/polym13122003 · Cited by 662
Metadata
- Authors
- Kappenman, E. S., & Luck, S. J.
- Venue
- Psychophysiology
- Publisher
- Wiley
- Published
- 2010-03
- Volume
- 47
- Issue
- 5
- Pages
- 888-904
- ISSN
- 0048-5772 (ISSN-L)
- 1469-8986
- OpenAlex
- W2158956772
- Cited by
- 447
- References
- 17
- FWCI
- 5.43
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.