Fetal umbilical artery flow velocity waveforms and placental resistance: clinical significance
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Summary. Since the umbilical arteries carry fetal blood to the placenta we studied flow velocity waveforms in these vessels with a simple continuous wave Doppler system to assess placental blood flow. The ratio of peak systolic to least diastolic (A/B) flow velocity was measured as an index of placental flow resistance. In 15 normal pregnancies there was a small but significant decrease in this ratio through the last trimester. The A/B ratio was measured on 436 occasions in 168 high‐risk pregnancies. In 32 of 43 fetuses subsequently shown to be small for gestational age there was an increase in placental flow resistance with reduced, absent or even reversed flow in diastole. This finding was also present in the one fetus which died in utero. Serial studies in patients with fetal compromise indicated increasing flow resistance, a reverse of the normal trend. These results were not available to the clinician yet of 24 fetuses born before 32 weeks 13 had a high A/B ratio, and all of them were born electively. Maternal hypertension was associated with an increase in fetal placental flow resistance. The umbilical artery A/B ratio provides a new and non‐invasive measure of fetoplacental blood flow resistance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Non-invasive measurement of human fetal circulation using ultrasound: a new method.
FitzGerald, D. E., & Drumm, J. E. (1977) · BMJ · doi:10.1136/bmj.2.6100.1450 · Cited by 397
FETAL BLOOD VELOCITY WAVEFORMS IN NORMAL PREGNANCY
Stuart, B., Drumm, J., FitzGerald, D. E., & Duignan, N. M. (1980) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1980.tb04613.x · Cited by 309
Pulsed Doppler with B-mode imaging for quantitative blood flow measurement
Gill, R. W. (1979) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(79)90014-0 · Cited by 265
Measurement of human fetal blood flow.
Sauders, J. B., Wright, N., & Lewis, K. O. (1980) · BMJ · doi:10.1136/bmj.280.6210.283 · Cited by 237
Fetal umbilical venous flow measured in utero by pulsed Doppler and B-mode ultrasound
Gill, R. W., Trudinger, B. J., Garrett, W. J., Kossoff, G., & Warren, P. S. (1981) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(81)90495-6 · Cited by 163
Self-citationFetal blood velocity waveforms
McCallum, W. D., Williams, C. S., Napel, S. A., & Daigle, R. E. (1978) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(78)90779-2 · Cited by 151
Physiological interpretation of doppler-shift waveforms—I theoretical considerations
Skidmore, R., & Woodcock, J. P. (1980) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(80)90057-5 · Cited by 87
Cardiovascular changes associated with fetal breathing
Fouron, J., Korcaz, Y., & Leduc, B. (1975) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(75)90864-9 · Cited by 37
AN INTRODUCTION TO SOME RECENT DEVELOPMENTS IN ARTERIAL HÆMODYNAMICS
TAYLOR, M. G. (1966) · Australasian Annals of Medicine · doi:10.1111/imj.1966.15.1.71 · Cited by 27
Cited by
Fetal umbilical artery flow velocity waveforms and placental resistance: pathological correlation
GILES, W. B., TRUDINGER, B. J., & BAIRD, P. J. (1985) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1985.tb01045.x · Cited by 724
Self-citationEffects of frequent ultrasound during pregnancy: a randomised controlled trial
Newnham, J. P., Evans, S. F., Michael, C. A., Stanley, F. J., & Landau, L. I. (1993) · The Lancet · doi:10.1016/0140-6736(93)91944-h · Cited by 642
Development of the placental villous tree and its consequences for fetal growth
Kingdom, J., Huppertz, B., Seaward, G., & Kaufmann, P. (2000) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/s0301-2115(00)00423-1 · Cited by 592
Doppler ultrasound assessment of cerebral blood flow in the human fetus
WLADIMIROFF, J. W., TONGE, H. M., & STEWART, P. A. (1986) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1986.tb07932.x · Cited by 474
Fetal and umbilical Doppler ultrasound in high-risk pregnancies
Alfirevic, Z., Stampalija, T., & Gyte, G. M. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007529.pub3 · Cited by 433
Doppler ultrasonography in high-risk pregnancies: Systematic review with meta-analysis
Alfirevic, Z., & Neilson, J. P. (1995) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(95)90466-2 · Cited by 415
Placental insufficiency and its consequences
Gagnon, R. (2003) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/s0301-2115(03)00179-9 · Cited by 330
Oxidative Stress and Preeclampsia: Rationale for Antioxidant Clinical Trials
Raijmakers, M. T. M., Dechend, R., & Poston, L. (2004) · Hypertension · doi:10.1161/01.hyp.0000141085.98320.01 · Cited by 330
Placental Pathology in Early-Onset and Late-Onset Fetal Growth Restriction
Mifsud, W., & Sebire, N. J. (2014) · Fetal Diagnosis and Therapy · doi:10.1159/000359969 · Cited by 328
PRENATAL STRESSORS OF HUMAN LIFE AFFECT FETAL BRAIN DEVELOPMENT
Lou, H. C., Hansen, D., Nordentoft, M., Pryds, O., Jensen, F., Nim, J., & Hetnmingsen, R. (1994) · Developmental Medicine & Child Neurology · doi:10.1111/j.1469-8749.1994.tb08192.x · Cited by 307
Fetal and umbilical Doppler ultrasound in high-risk pregnancies
Alfirevic, Z., Stampalija, T., & Dowswell, T. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007529.pub4 · Cited by 304
Oxidative stress, placental ageing-related pathologies and adverse pregnancy outcomes
Sultana, Z., Maiti, K., Aitken, J., Morris, J., Dedman, L., & Smith, R. (2017) · American Journal of Reproductive Immunology · doi:10.1111/aji.12653 · Cited by 288
Uteroplacental blood flow velocity‐time waveforms in normal and complicated pregnancy
TRUDINGER, B. J., GILES, W. B., & COOK, C. M. (1985) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1985.tb01046.x · Cited by 279
Self-citationRole of Placenta in Preeclampsia
Myatt, L. (2002) · Endocrine · doi:10.1385/endo:19:1:103 · Cited by 272
Developmental biology of the placenta and the origins of placental insufficiency
Chaddha, V., Viero, S., Huppertz, B., & Kingdom, J. (2004) · Seminars in Fetal and Neonatal Medicine · doi:10.1016/j.siny.2004.03.006 · Cited by 264
Flow velocity waveforms in the maternal uteroplacental and fetal umbilical placental circulations
Trudinger, B. J., Giles, W. B., & Cook, C. M. (1985) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(85)80016-8 · Cited by 255
Self-citationThe Doppler signal: where does it come from and what does it mean?
Nelson, T., & Pretorius, D. (1988) · American Journal of Roentgenology · doi:10.2214/ajr.151.3.439 · Cited by 249
“Duplex Doppler imaging offers many advantages over either continuous- or pulsed-wave Doppler, and it has been this technology that has allowed Doppler to become so clinically useful in evaluating carotid vessels [16-20], fetal and uterine vessels [ 21 -25 ], and abdominal vessels [1 0, 15, 26-28].”
BackgroundMethodTrudinger, B. J., Stevens, D., Connelly, A., Hales, J. R. S., Alexander, G., Bradley, L., Fawcett, A., & Thompson, R. S. (1987) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(87)80241-7 · Cited by 247
Self-citationEffect of placental embolization on the umbilical arterial velocity waveform in fetal sheep
Morrow, R. J., Adamson, S. L., Bull, S. B., & Knox Ritchie, J. W. (1989) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(89)90783-7 · Cited by 243
Jackson, M. R., Walsh, A. J., Morrow, R. J., Muller, B. M., Lye, S. J., & Ritchie, J. W. K. (1995) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(95)90566-9 · Cited by 230
Takagi, Y., Nikaido, T., Toki, T., Kita, N., Kanai, M., Ashida, T., Ohira, S., & Konishi, I. (2004) · Virchows Archiv · doi:10.1007/s00428-003-0903-2 · Cited by 225
“and to be the cause of placental hypoxia or ischemia [28].”
BackgroundNeuroendocrine Mechanisms in Pregnancy and Parturition
Petraglia, F., Imperatore, A., & Challis, J. R. G. (2010) · Endocrine Reviews · doi:10.1210/er.2009-0019 · Cited by 224
Low birth weight and risk of high blood pressure in adulthood
Gennser, G., Rymark, P., & Isberg, P. E. (1988) · BMJ · doi:10.1136/bmj.296.6635.1498 · Cited by 216
The significance of absent end-diastolic velocity in umbilical artery velocity waveforms
Rochelson, B., Schulman, H., Farmakides, G., Bracero, L., Ducey, J., Fleischer, A., Penny, B., & Winter, D. (1987) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(87)90147-5 · Cited by 196
Doppler ultrasound waveform indices: A/B ratio, pulsatility index and Pourcelot ratio
THOMPSON, R. S., TRUDINGER, B. J., & COOK, C. M. (1988) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1988.tb09487.x · Cited by 191
Self-citationMyatt, L., Eis, A. L., Brockman, D. E., Greer, I. A., & Lyall, F. (1997) · Human Reproduction · doi:10.1093/humrep/12.1.167 · Cited by 182
UMBILICAL ARTERY FLOW VELOCITY WAVEFORMS IN HIGH-RISK PREGNANCY
Trudinger, B., Giles, W., Cook, C., Connelly, A., & Thompson, R. (1987) · The Lancet · doi:10.1016/s0140-6736(87)90003-1 · Cited by 179
Self-citationFetal umbilical artery velocity waveforms and subsequent neonatal outcome
TRUDINGER, B. J., COOK, C. M., GILES, W. B., NG, S., FONG, E., CONNELLY, A., & WILCOX, W. (1991) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1991.tb13428.x · Cited by 179
Self-citationBrar, H. S., & Platt, L. D. (1988) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(88)80007-3 · Cited by 165
Control of vascular resistance in the human placenta
Myatt, L. (1992) · Placenta · doi:10.1016/0143-4004(92)90057-z · Cited by 163
Development and Mechanisms of Fetal Hypoxia in Severe Fetal Growth Restriction
Regnault, T. R. H., de Vrijer, B., Galan, H. L., Wilkening, R. B., Battaglia, F. C., & Meschia, G. (2007) · Placenta · doi:10.1016/j.placenta.2006.06.007 · Cited by 131
Louey, S., Jonker, S. S., Giraud, G. D., & Thornburg, K. L. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2006.122200 · Cited by 116
“These changes are commonly found in human cases of severe placental insufficiency (Trudinger et al. 1985).”
BackgroundMeasurement of arterial blood flow by Doppler ultrasound
Hoskins, P. R. (1990) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/11/1/001 · Cited by 109
Griffin, J. B., Lokomba, V., Landis, S. H., Thorp, J. M., Herring, A. H., Tshefu, A. K., Rogerson, S. J., & Meshnick, S. R. (2012) · Malaria Journal · doi:10.1186/1475-2875-11-319 · Cited by 97
“Abnormal uterine artery resistance is associated with pre-eclampsia, intrauterine growth restriction (IUGR) and adverse pregnancy outcomes [6], while increased umbilical artery resistance is associated with foetal distress and IUGR [7,8].”
BackgroundMathematical model for interpretation of Doppler velocity waveform indices
Thompson, R. S., & Stevens, R. J. (1989) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441484 · Cited by 71
Nugent, J. L., Wareing, M., Palin, V., Sibley, C. P., Baker, P. N., Ray, D. W., Farrow, S. N., & Jones, R. L. (2013) · Endocrinology · doi:10.1210/en.2012-1927 · Cited by 33
“In pregnancies complicated by FGR, Doppler waveform analyses of umbilical arteries identify an increase in resistance to blood flow in the fetoplacental circulation (5-7), indicating abnormal delivery of oxygen and nutrients to the fetus.”
BackgroundOxygen Sensitivity, Potassium Channels, and Regulation of Placental Vascular Tone
Wareing, M. (2014) · Microcirculation · doi:10.1111/micc.12069 · Cited by 30
Absence of End-Diastolic Flow Velocity in the Umbilical Artery: A Review
Forouzan, I. (1995) · Obstetrical & Gynecological Survey · doi:10.1097/00006254-199503000-00026 · Cited by 24
Beksaç, M. S., Başaran, F., Eskiizmirliler, S., Erkmen, A. M., & Yörükan, S. (1996) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/0301-2115(95)02256-2 · Cited by 23
Interpretation of Doppler blood flow velocity waveforms using neural networks.
(1994) · PubMed Central · Cited by 5
Metadata
- Authors
- TRUDINGER, B. J., GILES, W. B., COOK, C. M., BOMBARDIERI, J., & COLLINS, L.
- Venue
- BJOG: An International Journal of Obstetrics & Gynaecology
- Publisher
- Wiley
- Published
- 1985-01
- Volume
- 92
- Issue
- 1
- Pages
- 23-30
- ISSN
- 0306-5456 (ISSN-L)
- 1470-0328
- 1471-0528
- OpenAlex
- W2079282203
- Cited by
- 561
- References
- 9
- FWCI
- 65.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.