CoChat

Prediction of perinatal morbidity at term in small fetuses: comparison of fetal growth and Doppler ultrasound

Chang, Tou C., Robson, Stephen C., Spencer, John A. D., Gallivan, Steven · 1994 · BJOG: An International Journal of Obstetrics & Gynaecology
Cited by 117

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Objective To compare fetal growth assessed by ultrasound (change in standard deviation score of abdominal circumference and estimated fetal weight) during the third trimester with predelivery ultrasound measurements of fetal size and Doppler measurements from the umbilical and fetal arteries in order to predict suboptimal perinatal outcome in small babies at term. Design Prospective observational study. Setting Day assessment unit in a university hospital. Subjects One hundred and four consecutive women with a clinical suspicion of a small fetus during the third trimester confirmed by ultrasound (abdominal circumference below the 10th centile) and ultimately delivered at term. Main outcome measures Acidaemia at birth, fetal distress requiring emergency caesarean section in labour, admission to the neonatal intensive care unit. Results Ninety‐four babies (90%) weighed less than the 10th centile and the incidence of suboptimal perinatal outcome was 27%. The largest areas under the receiver operating characteristic curves for suboptimal perinatal outcome were obtained with the change in standard deviation score of abdominal circumference and estimated fetal weight, and the ratios of aortic/middle cerebral and renal/middle cerebral pulsatility index. Although low, the odds ratios of the change in estimated fetal weight standard deviation score and the Doppler ratios were significantly different from zero. Conclusion Ultrasound assessment of fetal growth and predelivery fetal Doppler pulsatility index ratios were superior to predelivery estimates of fetal size and umbilical artery pulsatility index in predicting suboptimal perinatal outcome in small fetuses delivering at term, although the clinical value of such a prediction may be limited.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1471-0528.1994.tb11916.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 117

Metadata

Authors
Chang, T. C., Robson, S. C., Spencer, J. A. D., & Gallivan, S.
Venue
BJOG: An International Journal of Obstetrics & Gynaecology
Publisher
Wiley
Published
1994-05
Volume
101
Issue
5
Pages
422-427
ISSN
  • 0306-5456 (ISSN-L)
  • 1470-0328
  • 1471-0528
OpenAlex
W2062719516
Cited by
117
References
2
FWCI
5.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prediction of perinatal morbidity at term in small fetuses: comparison of fetal growth and Doppler ultrasound. https://app.cochat.ai/papers/10.1111/j.1471-0528.1994.tb11916.x
The paper
Chang, T. C., Robson, S. C., Spencer, J. A. D., & Gallivan, S. (1994). Prediction of perinatal morbidity at term in small fetuses: comparison of fetal growth and Doppler ultrasound. BJOG: An International Journal of Obstetrics & Gynaecology. https://doi.org/10.1111/j.1471-0528.1994.tb11916.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.