Controlled trial of fundal height measurement plotted on customised antenatal growth charts
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Objective The purpose of this study was to evaluate the effect of a policy of standard antenatal care which included plotting fundal height measurements on customised antenatal charts in the community. Design Prospective, non‐randomised, controlled, population‐based study. Population Two defined and separate referral areas from community to teaching hospital, with similar delivery rates and socioeconomic characteristics. A total of 1272 consecutively booked women with singleton pregnancies and dating ultrasound scans before 22 weeks of gestation. Intervention In the study area customised fundal height charts were issued to each mother at the routine hospital booking scan, on which regular fundal height measurements were to be plotted by community midwives. The charts adjusted limits according to maternal characteristics including height, weight, parity and ethnic group. Usual management in the control area included fundal height assessment by abdominal palpation and recording on a standard co‐operation card. Outcome measures Antenatal detection of small and large for gestational age babies; number of antenatal investigations for fetal growth in each group. Results The study group had a significantly higher antenatal detection rate of small for gestational age babies (48%vs 29%, odds ratio 2.2, 95% confidence interval 1.145) and large for gestational age babies (46%vs 24%, OR 2.6, CI 1.3–5.5). There was no increase in the study group in the overall number of scans per pregnancy done in the ultrasound department (1.2 vs 1.3, P= 0.14), but a slight decrease in repeat (two or more) third trimester scans (OR 0.8, CI 0.6–11.0, P= 0.08). Women in the study group had significantly fewer referrals for investigation in a pregnancy assessment centre (OR 0.7, CI 0.5–0.9; P= 0.01) and fewer admissions to the antenatal ward (OR 0.6, CI 0.4–0.7, P= 0.001). There were no differences in perinatal outcome. Conclusions Serial measurement of fundal height plotted on customised charts leads to increased antenatal detection of small and large babies. This is accompanied by fewer investigations, which is likely to represent increased confidence in the community to recognise normal fetal growth. With adjustments for physiological variables, fundal height measurements appear to be a cost effective screening method which can result in substantial improvements in the antenatal assessment of fetal growth.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Practical Statistics for Medical Research
Altman, D. G. (1990) · doi:10.1201/9780429258589 · Cited by 10,668
CONSORT statement: extension to cluster randomised trials
Campbell, M. K., Elbourne, D. R., & Altman, D. G. (2004) · BMJ · doi:10.1136/bmj.328.7441.702 · Cited by 2,557
Customised antenatal growth charts
Gardosi, J., Chang, A., Kalyan, B., Sahota, D., & Symonds, E. M. (1992) · The Lancet · doi:10.1016/0140-6736(92)91342-6 · Cited by 843
Self-citationAn adjustable fetal weight standard
Gardosi, J., Mongelli, M., Wilcox, M., & Chang, A. (1995) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.1995.06030168.x · Cited by 568
Self-citationIS ROUTINE ANTENATAL CARE WORTH WHILE?
Hall, M., Chng, P. K., & Macgillivray, I. (1980) · The Lancet · doi:10.1016/s0140-6736(80)92950-5 · Cited by 253
Belizán, J., Villar, J., Nardin, J. C., Malamud, J., & De Vicuña, L. S. (1978) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(78)90824-4 · Cited by 218
Analysis of birthweight and gestational age in antepartum stillbirths
Gardosi, J., Mul, T., Mongelli, M., & Fagan, D. (1998) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1998.tb10153.x · Cited by 215
Self-citationGRAVIDOGRAM AND FETAL GROWTH: Comparison with Biochemical Supervision
Westin, B. (1977) · Acta Obstetricia et Gynecologica Scandinavica · doi:10.3109/00016347709154978 · Cited by 180
NOMOGRAMS FOR PRECISE DETERMINATION OF BIRTH WEIGHT FOR DATES
Altman, D. G., & Coles, E. C. (1980) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1980.tb04498.x · Cited by 153
de Jong, C. L. D., Gardosi, J. O., Dekker, G., Colenbrander, G. J., & van Geijn, H. P. (1998) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1998.tb10154.x · Cited by 148
Self-citationIntrauterine growth retardation: Let's be clear about it
Altman, D. G., & Hytten, F. E. (1989) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1989.tb03185.x · Cited by 146
PREDICTION OF SMALL‐FOR‐DATES INFANTS BY MEASUREMENT OF SYMPHYSIAL‐FUNDAL‐HEIGHT
Quaranta, P. A., Currell, R., Redman, C. W. G., & Robinson, J. S. (1981) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1981.tb00952.x · Cited by 143
Soothill, P. W., Ajayi, R. A., Campbell, S., & Nicolaides, K. H. (1993) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1993.tb14265.x · Cited by 141
MONGELLI, M., & GARDOSI, J. (1996) · Obstetrics & Gynecology · doi:10.1016/0029-7844(96)00285-2 · Cited by 141
Self-citationNeonatal morphometrics and perinatal outcome: Who is growth retarded?
PATTERSON, R. M., & Pouliot, M. R. (1987) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(87)80030-3 · Cited by 138
Antenatal screening by measurement of symphysis-fundus height.
CALVERT, J. P., CREAN, E. E., Newcombe, R. G., & Pearson, J. F. (1982) · BMJ · doi:10.1136/bmj.285.6345.846 · Cited by 131
BEAZLEY, J. M., & Underhill, R. A. (1970) · BMJ · doi:10.1136/bmj.4.5732.404 · Cited by 114
Prediction of size of infants at birth by measurement of symphysis fundus height
PERSSON, B., STANGENBERG, M., LUNELL, N. O., BRODIN, U., HOLMBERG, N. G., & VACLAVINKOVA, V. (1986) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1986.tb07894.x · Cited by 103
An audit of the detection and management of small-for-gestational age babies
HEPBURN, M., & ROSENBERG, K. (1986) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1986.tb07895.x · Cited by 100
The individualised birth weight ratio: a new method of identifying intrauterine growth retardation
Sanderson, D. A., Wilcox, M. A., & Johnson, I. R. (1994) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1994.tb13616.x · Cited by 99
The clinical prediction of intrauterine growth retardation
Galbraith, R. S., Karchmar, E. J., Piercy, W. N., & Low, J. A. (1979) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(79)90679-3 · Cited by 99
Longitudinal study of fetal growth in subgroups of a low‐risk population
Mongelli, M., & Gardosi, J. (1995) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.1995.06050340.x · Cited by 96
Self-citationLINDHARD, A., NIELSEN, P. V., MOURITSEN, L. A., ZACHARIASSEN, A., SØRENSEN, H. U., & ROSENØ, H. (1990) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1990.tb16237.x · Cited by 92
Chang, T. C., Robson, S. C., Spencer, J. A. D., & Gallivan, S. (1994) · International Journal of Gynecology & Obstetrics · doi:10.1016/0020-7292(94)90145-7 · Cited by 86
Measurement of fundal height as a screening test for fetal growth retardation
Rosenberg, K., Grant, J. M., TWEEDIE, I., Aitchison, T. C., & Gallagher, F. (1982) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1982.tb03634.x · Cited by 85
Screening for the small-for-dates fetus: a two-stage ultrasonic examination schedule.
Nielson, J., Whitfield, C. R., & Aitchison, T. C. (1980) · BMJ · doi:10.1136/bmj.280.6225.1203 · Cited by 74
BAILEY, S. M., SARMANDAL, P., & Grant, J. M. (1989) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1989.tb03223.x · Cited by 70
Kean, L. H., & Liu, D. T. Y. (1996) · Journal of Obstetrics and Gynaecology · doi:10.3109/01443619609007744 · Cited by 65
SYMPHYSIS‐FUNDUS MEASUREMENT IN PREDICTION OF FETAL GROWTH DISTURBANCES
Wallin, A., GYLLENSWÄRD, A., & Westin, B. (1981) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.3109/00016348109158139 · Cited by 50
Symphysis‐fundus Measurements and Intrauterine Growth Retardation
Cnattingius, S., Axelssön, O., & Lindmark, G. (1984) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.3109/00016348409155527 · Cited by 49
Harding, K., Evans, S. F., & Newnham, J. P. (1995) · Australian and New Zealand Journal of Obstetrics and Gynaecology · doi:10.1111/j.1479-828x.1995.tb01859.x · Cited by 47
Steingrímsdóttir, Þ., Cnattingius, S., & Lindmark, G. (1995) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.3109/00016349509024426 · Cited by 41
Evaluation of Fundal Height Measurement in Antenatal Care
Rogers, M. S., & Needham, P. G. (1985) · Australian and New Zealand Journal of Obstetrics and Gynaecology · doi:10.1111/j.1479-828x.1985.tb00614.x · Cited by 32
Grover, V., Usha, R., Kalra, S., & Sachdeva, S. (1991) · International Journal of Gynecology & Obstetrics · doi:10.1016/0020-7292(91)90291-c · Cited by 29
Cited by
Maternal and fetal risk factors for stillbirth: population based study
Gardosi, J., Madurasinghe, V., Williams, M., Malik, A., & Francis, A. (2013) · BMJ · doi:10.1136/bmj.f108 · Cited by 941
Self-citationCarroli, G., Rooney, C., & Villar, J. (2001) · Paediatric and Perinatal Epidemiology · doi:10.1046/j.1365-3016.2001.0150s1001.x · Cited by 622
Intrauterine growth restriction: new concepts in antenatal surveillance, diagnosis, and management
Figueras, F., & Gardosi, J. (2011) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2010.08.055 · Cited by 485
Self-citationNew Dutch reference curves for birthweight by gestational age
Visser, G. H. A., Eilers, P. H. C., Elferink-Stinkens, P. M., Merkus, H. M. W. M., & Wit, J. M. (2009) · Early Human Development · doi:10.1016/j.earlhumdev.2009.09.008 · Cited by 340
Customized growth charts: rationale, validation and clinical benefits
Gardosi, J., Francis, A., Turner, S., & Williams, M. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2017.12.011 · Cited by 239
“A controlled study has shown that training in standardized fundal height measurement and plotting on customized charts significantly increased antenatal detection of SGA and LGA fetuses while reducing false-positive diagnoses.(64)”
Self-citation
Metadata
- Authors
- Gardosi, J., & Francis, A.
- Venue
- BJOG: An International Journal of Obstetrics & Gynaecology
- Publisher
- Wiley
- Published
- 1999-04
- Volume
- 106
- Issue
- 4
- Pages
- 309-317
- ISSN
- 0306-5456 (ISSN-L)
- 1470-0328
- 1471-0528
- OpenAlex
- W2168599832
- Cited by
- 172
- References
- 34
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.