Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 227

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

The value of sonography in early pregnancy for the detection of fetal abnormalities in an unselected population

Whitlow, B. J., Chatzipapas, I. K., Lazanakis, M. L., Kadir, R. A., Economides, D. L. · 1999 · BJOG: An International Journal of Obstetrics & Gynaecology

Abstract

Objective To determine the value of early pregnancy sonography in detecting fetal abnormalities in an unselected obstetric population. Design Prospective cross‐sectional study. All women initially underwent transabdominal sonography and when the anatomical survey was considered to be incomplete, transvaginal sonography was also performed (20.1 %). Nuchal translucency was measured and karyotyping was performed as appropriate. Setting University Department of Obstetrics and Gynaecology. Participants 6634 sequential unselected women (mean maternal age 29–9 years, range 13–50; mean gestational age 12+4 weeks, range 11+0‐14+6), carrying 6443 live fetuses participated in this study. Main outcome measure Detection rate of fetal anomalies and the associated cost per case detected in early pregnancy. Results The incidence of anomalous fetuses was 1.4% (926443) including 43 chromosomal abnormalities. The detection rate for structural abnormalities was 59.0% (37/63, 95% CI 46.5–72.4) and the specificity was 99.9% in early pregnancy. When the first and second trimester scans were combined, the detection for structural abnormalities was 8 1.0% (5 1/63, 95% CI 67.7–89.2). Seventy‐eight percent (31/40) of chromosomal abnormalities (excluding three cases of XXY) were diagnosed at 11–14 weeks, either because of a nuchal translucency greater than or equal to the 99th centile for gestational age (43%; 17/40,95% CI 27‐4–60.4), or due to the presence of structural abnormalities (35%; 14/40, 95% CI 21.2–52.8). Sixty‐five percent (15/23) of cases of trisomy 21 were also diagnosed either because of having a nuchal translucency greater than or equal to the 99th centile (57.0%; 13/23) or due to the presence of a structural abnormality (9.0%; 2/23). Overall, the detection rate of structurally abnormal fetuses was 59% (37/63) in early pregnancy and 81% in combination with the second trimester scan. The cost per abnormality diagnosed in early pregnancy is estimated to be f6258 per structurally abnormal fetus, £7470 per chromosomal abnormality and f4453 per anomalous fetus. Conclusion The majority of fetal structural and chromosomal abnormalities can be detected by sonographic screening at 11–14 weeks, but the second trimester scan should not be abandoned.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1471-0528.1999.tb08432.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 227

Metadata

Authors
Whitlow, B. J., Chatzipapas, I. K., Lazanakis, M. L., Kadir, R. A., & Economides, D. L.
Venue
BJOG: An International Journal of Obstetrics & Gynaecology
Publisher
Wiley
Published
1999-09
Volume
106
Issue
9
Pages
929-936
ISSN
  • 0306-5456 (ISSN-L)
  • 1470-0328
  • 1471-0528
OpenAlex
W2033176881
Cited by
227
References
1
FWCI
7.77
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The value of sonography in early pregnancy for the detection of fetal abnormalities in an unselected population. https://app.cochat.ai/papers/10.1111/j.1471-0528.1999.tb08432.x
The paper
Whitlow, B. J., Chatzipapas, I. K., Lazanakis, M. L., Kadir, R. A., & Economides, D. L. (1999). The value of sonography in early pregnancy for the detection of fetal abnormalities in an unselected population. BJOG: An International Journal of Obstetrics & Gynaecology. https://doi.org/10.1111/j.1471-0528.1999.tb08432.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.