CoChat

Ambulatory blood pressure monitoring and cardiovascular function tests in multiple system atrophy

Frongillo, D., Stocchi, F., Buccolini, P., Stecconi, P., Viselli, F., Ruggieri, S., Cannata, D. · 1995 · Fundamental & Clinical Pharmacology
Cited by 17

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Summary— Cardiovascular tests (CT) of autonomic function and non‐invasive ambulatory blood pressure (BP) and heart rate (HR) monitoring were performed in 17 patients with multiple system atrophy (MSA) (mean age 61 ± 9 years) and in 12 healthy subjects matched for sex and age. CT showed severe autonomic dysfunction with orthostatic hypotension (OH) in eight patients with MSA (47%) (Group I). The remaining nine out of the 17 patients didn't show BP abnormalities during CT but an impaired HR reflex response was found (Group II). BP monitoring showed a reversed circadian BP rhythm in Group I with higher night‐time than day‐time values, a blunted circadian BP pattern in Group II and a normal day‐night BP reduction in controls. Day‐night HR reduction was poor in Group II and absent in Group I. Post‐prandial hypotension was evaluated after a standard meal. In Group I systolic/diastolic BP fell within 30 minutes after meal (from 135 ± 16/89 ± 13 to 118 ± 17/73 ± 12 mmHg; p < 0.05) and after two hours had not returned to basal levels. In Group II a reduction of only systolic BP was found within 45 minutes after meal and persisted for one hour. OH clinically identifies a subgroup of MSA patients with a more severe BP dysregulation characterized by severe post‐prandial hypotension and reversed circadian BP rhythm. CT and ambulatory BP monitoring are useful tools in identifying early stage of cardiovascular autonomic impairment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1472-8206.1995.tb00280.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 17

Metadata

Authors
Frongillo, D., Stocchi, F., Buccolini, P., Stecconi, P., Viselli, F., Ruggieri, S., & Cannata, D.
Venue
Fundamental & Clinical Pharmacology
Publisher
Wiley
Published
1995-03-04
Volume
9
Issue
2
Pages
187-196
ISSN
  • 0767-3981 (ISSN-L)
  • 1472-8206
OpenAlex
W2165598172
Cited by
17
References
1
FWCI
0.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ambulatory blood pressure monitoring and cardiovascular function tests in multiple system atrophy. https://app.cochat.ai/papers/10.1111/j.1472-8206.1995.tb00280.x
The paper
Frongillo, D., Stocchi, F., Buccolini, P., Stecconi, P., Viselli, F., Ruggieri, S., & Cannata, D. (1995). Ambulatory blood pressure monitoring and cardiovascular function tests in multiple system atrophy. Fundamental & Clinical Pharmacology. https://doi.org/10.1111/j.1472-8206.1995.tb00280.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.