CoChat

Spontaneous baroreflex by sequence and power spectral methods in humans,

Hughson, R. L., Quintin, L., Annat, G., Yamamoto, Y., Gharib, C. · 1993 · Clinical Physiology
Cited by 147

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Summary. Beat‐by‐beat variations in blood pressure and RR‐interval are interrelated by the actions of baroreflex and non‐baroreflex responses. This study had two purposes: (1) to examine the spontaneous relationships between RR‐interval and systolic blood pressure to determine the relative occurrence of baroreflex and non‐baroreflex responses in humans, and (2) to compare the beat‐sequence method with a cross spectral estimate of the baroreflex response slope. Eight healthy men were studied during 10 h of quiet, seated rest, and six men and three women were studied during rest, rest plus fixed pace breathing, and a cold pressor test. RR‐interval and continuous, non‐invasive arterial blood pressure were measured with a computerized system. A baroreflex sequence was defined by a series of at least three consecutive heart beats in which systolic pressure and the following RR‐interval either both increased or both decreased. A non‐baroreflex relationship was defined by sequences of at least three beats by opposite directional changes of RR‐interval and systolic pressure of that beat. The results showed that there were approximately 30% as many non‐baroreflex compared to baroreflex slopes. Individual subject mean baroreflex and non‐baroreflex slopes were highly correlated (r= 0–72, P < 0–001). Absolute slope values were not different, and they were unaffected by time, fixed pace breathing, or cold pressor test. The data showed the relatively simple beat‐by‐beat sequence method to yield spontaneous baroreflex response slopes that were quantitatively similar to, and highly correlated with (r= 0–85‐0‐94), baroreflex response slopes calculated by spectral analysis methods.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1475-097x.1993.tb00481.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 147

Metadata

Authors
Hughson, R. L., Quintin, L., Annat, G., Yamamoto, Y., & Gharib, C.
Venue
Clinical Physiology
Publisher
Wiley
Published
1993-11
Volume
13
Issue
6
Pages
663-676
ISSN
  • 0144-5979 (ISSN-L)
  • 1365-2281
OpenAlex
W2098361019
Cited by
147
References
2
FWCI
2.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Spontaneous baroreflex by sequence and power spectral methods in humans,. https://app.cochat.ai/papers/10.1111/j.1475-097x.1993.tb00481.x
The paper
Hughson, R. L., Quintin, L., Annat, G., Yamamoto, Y., & Gharib, C. (1993). Spontaneous baroreflex by sequence and power spectral methods in humans,. Clinical Physiology. https://doi.org/10.1111/j.1475-097x.1993.tb00481.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.