DISCOVERY, PRODUCTION AND USE OF TIN‐BASED OPACIFIERS IN GLASSES, ENAMELS AND GLAZES FROM THE LATE IRON AGE ONWARDS: A REASSESSMENT*
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Tin‐based opacifiers (lead stannate yellow and tin oxide white) were first used in glass production for a short period in Europe from the second to the first centuries bc, and then again throughout the Roman and Byzantine Empires from the fourth century ad onwards. Tin oxide was also used in the production of Islamic opaque glazes from the ninth century ad, and subsequently in enamels applied to Islamic and Venetian glasses from the 12th century ad onwards. A selection of published analytical data for the tin‐opacified glasses, enamels and glazes is summarized, and the methods used in their production are reassessed. The phase transformations occurring when mixtures of lead oxide, tin oxide and silica are fired are investigated with high temperature X‐ray diffraction (XRD) using a synchrotron radiation source, and these results are used to explain the observed differences in the glass, enamel and glaze compositions. Possible reasons for the use of tin‐based opacifiers in the second to first centuries bc, and for the switch from antimony‐ to tin‐based opacifiers in the fourth century ad are suggested, and the possible contexts in which tin‐based opacifiers might have been discovered are considered. The introduction of tin‐opacified glazes by Islamic potters in the ninth century ad is discussed in terms of technological transfer or independent invention.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-dimensional detector software: From real detector to idealised image or two-theta scan
Hammersley, A. P., Svensson, S. O., Hanfland, M., Fitch, A. N., & Hausermann, D. (1996) · High Pressure Research · doi:10.1080/08957959608201408 · Cited by 4,674
LEAD GLAZES IN ANTIQUITY—METHODS OF PRODUCTION AND REASONS FOR USE*
TITE, M. S., FREESTONE, I., MASON, R., MOLERA, J., VENDRELL‐SAZ, M., & WOOD, N. (1998) · Archaeometry · doi:10.1111/j.1475-4754.1998.tb00836.x · Cited by 321
Self-citationAbū'l-Qāsim's Treatise on Ceramics
Allan, J. W. (1973) · Iran · doi:10.2307/4300488 · Cited by 162
ISLAMIC GLASS WEIGHTS AND STAMPS: ANALYSIS USING NUCLEAR TECHNIQUES
Gratuze, B., & Barrandon, J. N. (1990) · Archaeometry · doi:10.1111/j.1475-4754.1990.tb00462.x · Cited by 135
The Production of Lead–Tin Yellow at Merovingian Schleitheim (Switzerland)*
Heck, M., Rehren, T., & Hoffmann, P. S. (2003) · Archaeometry · doi:10.1111/1475-4754.00095 · Cited by 49
Cited by
Pion, C., & Gratuze, B. (2016) · Archaeological Research in Asia · doi:10.1016/j.ara.2016.02.005 · Cited by 36
Dussubieux, L., Bellina, B., Oo, W. H., Win, U. M. S., Tut, H. M., Htwe, K. M. M., & Kyaw, K. (2020) · Archaeological and Anthropological Sciences · doi:10.1007/s12520-020-01095-1 · Cited by 14
Wang, K.-W., Iizuka, Y., & Jackson, C. (2022) · PLOS ONE · doi:10.1371/journal.pone.0263986 · Cited by 6
Metadata
- Authors
- TITE, M., PRADELL, T., & SHORTLAND, A.
- Venue
- Archaeometry
- Publisher
- Wiley
- Published
- 2007-10-22
- Volume
- 50
- Issue
- 1
- Pages
- 67-84
- ISSN
- 0003-813X (ISSN-L)
- 1475-4754
- OpenAlex
- W2062266871
- Cited by
- 248
- References
- 5
- FWCI
- 38.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.