Surface‐Treated Catheters—A Review
Open accessThe DOI matches its Crossref record.
Abstract
Almost 30% of prevalent hemodialysis patients use catheters for vascular access although outcomes are superior with the use of either an arteriovenous fistula or a synthetic graft. Catheter complications are a major cause of morbidity and mortality for hemodialysis patients and increase the burden on the health care system. Surface‐treated catheters have been developed to combat the three most common causes of catheter failure: infection, fibrin sheath formation, and thrombus formation. Two types of catheter surface treatments are available: antimicrobial coatings and antithrombotic coatings. Surface treatment of central venous catheters with antimicrobial materials reduces both bacterial colonization and the incidence of catheter‐related bacteremia in critical care patients by 30–50%. Antithrombotic coatings reduce platelet adhesion, inhibit the inflammatory response, and reduce thrombus formation on coronary stents, ventricular assist devices, central venous catheters, and vascular grafts. However, few reports on the use of surface‐treated catheters in the chronic hemodialysis patient population exist. At the present time, it is difficult to justify the increased cost of surface‐treated catheters for chronic hemodialysis in the absence of clinical data demonstrating that they reduce catheter‐related complications in this patient population.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Silver Nanoparticles: Therapeutical Uses, Toxicity, and Safety Issues
Dos Santos, C. A., Seckler, M. M., Ingle, A. P., Gupta, I., Galdiero, S., Galdiero, M., Gade, A., & Rai, M. (2014) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.24001 · Cited by 531
The role of lipopolysaccharide-induced cell signalling in chronic inflammation
Page, M. J., Kell, D. B., & Pretorius, E. (2022) · Chronic Stress · doi:10.1177/24705470221076390 · Cited by 315
Guía Clínica Española del Acceso Vascular para Hemodiálisis
Ibeas, J., Roca-Tey, R., Vallespín, J., Moreno, T., Moñux, G., Martí-Monrós, A., del Pozo, J. L., Gruss, E., Ramírez de Arellano, M., Fontseré, N., et al. (2017) · Nefrología · doi:10.1016/j.nefro.2017.11.004 · Cited by 214
Vanholder, R., Canaud, B., Fluck, R., Jadoul, M., Labriola, L., Marti-Monros, A., Tordoir, J., & Van Biesen, W. (2010) · Clinical Kidney Journal · doi:10.1093/ndtplus/sfq041 · Cited by 124
“They essentially consist of silver sulfadiazine, heparin, TrilliumR [40] and/or coating with protective polymer layers preventing BaSO4 release from the catheter surface [41].”
BackgroundInfluentialCarboxyl-ebselen-based layer-by-layer films as potential antithrombotic and antimicrobial coatings
Cai, W., Wu, J., Xi, C., Ashe, A. J., & Meyerhoff, M. E. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.06.075 · Cited by 72
“Thrombus formation and bacterial infection are two common problems that lead to complications of blood-contacting biomedical devices such as catheters, vascular grafts and heart valves [1,2].”
Metadata
- Authors
- Dwyer, A.
- Venue
- Seminars in Dialysis
- Publisher
- Wiley
- Published
- 2008-11
- Volume
- 21
- Issue
- 6
- Pages
- 542-546
- ISSN
- 0894-0959 (ISSN-L)
- 1525-139X
- OpenAlex
- W1893168058
- Cited by
- 63
- References
- 0
- FWCI
- 7.97
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Surface‐Treated Catheters—A Review. https://app.cochat.ai/papers/10.1111/j.1525-139x.2008.00499.x
- The paper
- Dwyer, A. (2008). Surface‐Treated Catheters—A Review. Seminars in Dialysis. https://doi.org/10.1111/j.1525-139x.2008.00499.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.