CoChat

Noninvasive Blood Glucose Sensors Based on Near‐Infrared Spectroscopy

Heise, H.M., Marbach, R., Koschinsky, Th., Gries, F.A. · 1994 · Artificial Organs
Cited by 156

The DOI matches its Crossref record.

Abstract

Research into noninvasive devices for self‐monitoring of blood glucose is mainly based on near‐infrared spectroscopy. Such a device is particularly desirable in the intensive therapy of patients with diabetes mellitus to achieve optimal metabolic control through frequent glucose testing. The state of noninvasive assay technology is presented. Using diffuse reflectance spectra of mucous lip tissue has advantages and drawbacks compared with tissue transmittance experiments. Different approaches have been proposed in the patent literature; however, current technology requires further significant improvements, particularly within the lower normal and hypoglycemic glucose concentration ranges.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1525-1594.1994.tb02230.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 15

  1. 10.1366/000370292789619232 · DOI
  2. Marbach R., 1993, Meßverfahren zur IR‐spektroskopischen Blutglucosebestimmung
  3. 10.1117/12.56396 · doi:10.1117/12.56396
  4. 10.1007/BF02030737 · DOI · Paper page
  5. 10.2337/diacare.11.8.619 · DOI
  6. Robinson MR, 1992, Noninvasive glucose monitoring in diabetic patients: a preliminary evaluation, Clin Chem, 38, 1618, 10.1093/clinchem/38.9.1618 · DOI · Paper page
  7. Heise HM., 1991, Infrarot‐Spektroskopie und ihre potentiellen Möglichkeiten in der klinischen Chemie, Lab Med., 15, 470
  8. 10.1007/BF02446645 · DOI
  9. 10.1366/0003702934415354 · DOI · Paper page
  10. Murray I., 1992, Making light work: Advances in near infrared spectroscopy
  11. 10.1364/AO.22.002456 · DOI · Paper page
  12. 10.1117/12.56397 · doi:10.1117/12.56397
  13. 10.1016/0165-9936(92)87088-2 · doi:10.1016/0165-9936(92)87088-2
  14. Jansson PA, 1988, Characterization by microdialysis of intercellular glucose level in subcutaneous tissue in humans, Am J Physiol, 255, E218
  15. HeiseHM MarbachR.Effect of data pretreatment on the noninvasive blood glucose measurement by diffuse reflectance NIR spectroscopy. In:BertieJE WieserH. eds.Proceedings of the 9th Int. Conference on Fourier Transform Spectroscopy. Proc SPIE1993 2089:114–115. · doi:10.1117/12.166662

Cited by

See all 156

Metadata

Authors
Heise, H. M., Marbach, R., Koschinsky, T., & Gries, F. A.
Venue
Artificial Organs
Publisher
Wiley
Published
1994-06
Volume
18
Issue
6
Pages
439-447
ISSN
  • 0160-564X (ISSN-L)
  • 1525-1594
OpenAlex
W2048732705
Cited by
156
References
0
FWCI
3.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Noninvasive Blood Glucose Sensors Based on Near‐Infrared Spectroscopy. https://app.cochat.ai/papers/10.1111/j.1525-1594.1994.tb02230.x
The paper
Heise, H. M., Marbach, R., Koschinsky, T., & Gries, F. A. (1994). Noninvasive Blood Glucose Sensors Based on Near‐Infrared Spectroscopy. Artificial Organs. https://doi.org/10.1111/j.1525-1594.1994.tb02230.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.