Noninvasive Blood Glucose Sensors Based on Near‐Infrared Spectroscopy
The DOI matches its Crossref record.
Abstract
Research into noninvasive devices for self‐monitoring of blood glucose is mainly based on near‐infrared spectroscopy. Such a device is particularly desirable in the intensive therapy of patients with diabetes mellitus to achieve optimal metabolic control through frequent glucose testing. The state of noninvasive assay technology is presented. Using diffuse reflectance spectra of mucous lip tissue has advantages and drawbacks compared with tissue transmittance experiments. Different approaches have been proposed in the patent literature; however, current technology requires further significant improvements, particularly within the lower normal and hypoglycemic glucose concentration ranges.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 15
- 10.1366/000370292789619232 · DOI
- Marbach R., 1993, Meßverfahren zur IR‐spektroskopischen Blutglucosebestimmung
- 10.1117/12.56396 · doi:10.1117/12.56396
- 10.1007/BF02030737 · DOI · Paper page
- 10.2337/diacare.11.8.619 · DOI
- Robinson MR, 1992, Noninvasive glucose monitoring in diabetic patients: a preliminary evaluation, Clin Chem, 38, 1618, 10.1093/clinchem/38.9.1618 · DOI · Paper page
- Heise HM., 1991, Infrarot‐Spektroskopie und ihre potentiellen Möglichkeiten in der klinischen Chemie, Lab Med., 15, 470
- 10.1007/BF02446645 · DOI
- 10.1366/0003702934415354 · DOI · Paper page
- Murray I., 1992, Making light work: Advances in near infrared spectroscopy
- 10.1364/AO.22.002456 · DOI · Paper page
- 10.1117/12.56397 · doi:10.1117/12.56397
- 10.1016/0165-9936(92)87088-2 · doi:10.1016/0165-9936(92)87088-2
- Jansson PA, 1988, Characterization by microdialysis of intercellular glucose level in subcutaneous tissue in humans, Am J Physiol, 255, E218
- HeiseHM MarbachR.Effect of data pretreatment on the noninvasive blood glucose measurement by diffuse reflectance NIR spectroscopy. In:BertieJE WieserH. eds.Proceedings of the 9th Int. Conference on Fourier Transform Spectroscopy. Proc SPIE1993 2089:114–115. · doi:10.1117/12.166662
Cited by
Prospects and limitations of non-invasive blood glucose monitoring using near-infrared spectroscopy
Yadav, J., Rani, A., Singh, V., & Murari, B. M. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.01.005 · Cited by 374
Spectroscopic and Clinical Aspects of Noninvasive Glucose Measurements
Khalil, O. S. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.2.165 · Cited by 331
Advances in cost-effective integrated spectrometers
Li, A., Yao, C., Xia, J., Wang, H., Cheng, Q., Penty, R., Fainman, Y., & Pan, S. (2022) · Light: Science & Applications · doi:10.1038/s41377-022-00853-1 · Cited by 309
Noninvasive Monitoring of Blood Glucose with Raman Spectroscopy
Pandey, R., Paidi, S. K., Valdez, T. A., Zhang, C., Spegazzini, N., Dasari, R. R., & Barman, I. (2017) · Accounts of Chemical Research · doi:10.1021/acs.accounts.6b00472 · Cited by 290
Raman spectroscopy for noninvasive glucose measurements
Enejder, A. M. K., Scecina, T. G., Oh, J., Hunter, M., Shih, W.-C., Sasic, S., Horowitz, G. L., & Feld, M. S. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1920212 · Cited by 271
Metadata
- Authors
- Heise, H. M., Marbach, R., Koschinsky, T., & Gries, F. A.
- Venue
- Artificial Organs
- Publisher
- Wiley
- Published
- 1994-06
- Volume
- 18
- Issue
- 6
- Pages
- 439-447
- ISSN
- 0160-564X (ISSN-L)
- 1525-1594
- OpenAlex
- W2048732705
- Cited by
- 156
- References
- 0
- FWCI
- 3.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive Blood Glucose Sensors Based on Near‐Infrared Spectroscopy. https://app.cochat.ai/papers/10.1111/j.1525-1594.1994.tb02230.x
- The paper
- Heise, H. M., Marbach, R., Koschinsky, T., & Gries, F. A. (1994). Noninvasive Blood Glucose Sensors Based on Near‐Infrared Spectroscopy. Artificial Organs. https://doi.org/10.1111/j.1525-1594.1994.tb02230.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.