The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Raman spectroscopy for noninvasive glucose measurements
Open accessAbstract
We report the first successful study of the use of Raman spectroscopy for quantitative, noninvasive ("transcutaneous") measurement of blood analytes, using glucose as an example. As an initial evaluation of the ability of Raman spectroscopy to measure glucose transcutaneously, we studied 17 healthy human subjects whose blood glucose levels were elevated over a period of 2-3 h using a standard glucose tolerance test protocol. During the test, 461 Raman spectra were collected transcutaneously along with glucose reference values provided by standard capillary blood analysis. A partial least squares calibration was created from the data from each subject and validated using leave-one-out cross validation. The mean absolute errors for each subject were 7.8%+/-1.8% (mean+/-std) with R2 values of 0.83+/-0.10. We provide spectral evidence that the glucose spectrum is an important part of the calibrations by analysis of the calibration regression vectors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Global and societal implications of the diabetes epidemic
Zimmet, P., Alberti, K. G. M. M., & Shaw, J. (2001) · Nature · doi:10.1038/414782a · Cited by 5,883
Haaland, D. M., & Thomas, E. V. (1988) · Analytical Chemistry · doi:10.1021/ac00162a020 · Cited by 2,539
Prospects for in vivo Raman spectroscopy
Hanlon, E. B., Manoharan, R., Koo, T.-W., Shafer, K. E., Motz, J. T., Fitzmaurice, M., Kramer, J. R., Itzkan, I., Dasari, R. R., & Feld, M. S. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/2/201 · Cited by 894
Self-citationStructure of Water, Proteins, and Lipids in Intact Human Skin, Hair, and Nail
Gniadecka, M., Nielsen, O. F., Christensen, D. H., & Wulf, H. C. (1998) · Journal of Investigative Dermatology · doi:10.1046/j.1523-1747.1998.00146.x · Cited by 351
Spectroscopic and Clinical Aspects of Noninvasive Glucose Measurements
Khalil, O. S. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.2.165 · Cited by 331
In vitro andin vivo Raman spectroscopy of human skin
Caspers, P. J., Lucassen, G. W., Wolthuis, R., Bruining, H. A., & Puppels, G. J. (1998) · Biospectroscopy · doi:10.1002/(sici)1520-6343(1998)4:5+<s31::aid-bspy4>3.0.co;2-m · Cited by 314
Haka, A. S., Shafer‐Peltier, K., Fitzmaurice, M., Crowe, J. P., Dasari, R. R., & Feld, M. S. (2002) · PubMed · Cited by 302
Self-citationNoninvasive Glucose Monitoring in Diabetic Patients: A Preliminary Evaluation
Robinson, M. R., Eaton, R. P., Haaland, D. M., Koepp, G. W., Thomas, E. V., Stallard, B. R., & Robinson, P. L. (1992) · Clinical Chemistry · doi:10.1093/clinchem/38.9.1618 · Cited by 284
Multicomponent blood analysis by near-infrared Raman spectroscopy
Berger, A. J., Koo, T.-W., Itzkan, I., Horowitz, G., & Feld, M. S. (1999) · Applied Optics · doi:10.1364/ao.38.002916 · Cited by 255
Self-citation
Cited by
Raman and infrared spectroscopy of carbohydrates: A review
Wiercigroch, E., Szafraniec, E., Czamara, K., Pacia, M. Z., Majzner, K., Kochan, K., Kaczor, A., Baranska, M., & Malek, K. (2017) · Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2017.05.045 · Cited by 1,067
Automated Autofluorescence Background Subtraction Algorithm for Biomedical Raman Spectroscopy
Zhao, J., Lui, H., McLean, D. I., & Zeng, H. (2007) · Applied Spectroscopy · doi:10.1366/000370207782597003 · Cited by 810
Glucose sensors: a review of current and emerging technology
Oliver, N. S., Toumazou, C., Cass, A. E. G., & Johnston, D. G. (2009) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02642.x · Cited by 584
Biocompatible Materials for Continuous Glucose Monitoring Devices
Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H., & Schoenfisch, M. H. (2013) · Chemical Reviews · doi:10.1021/cr300387j · Cited by 347
Raman Spectroscopy of Blood and Blood Components
Atkins, C. G., Buckley, K., Blades, M. W., & Turner, R. F. B. (2017) · Applied Spectroscopy · doi:10.1177/0003702816686593 · Cited by 292
Metadata
- Authors
- Enejder, A. M. K., Scecina, T. G., Oh, J., Hunter, M., Shih, W.-C., Sasic, S., Horowitz, G. L., & Feld, M. S.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2005
- Volume
- 10
- Issue
- 3
- Pages
- 031114
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2139033211
- Cited by
- 271
- References
- 17
- FWCI
- 5.44
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Raman spectroscopy for noninvasive glucose measurements. https://app.cochat.ai/papers/10.1117/1.1920212
- The paper
- Enejder, A. M. K., Scecina, T. G., Oh, J., Hunter, M., Shih, W.-C., Sasic, S., Horowitz, G. L., & Feld, M. S. (2005). Raman spectroscopy for noninvasive glucose measurements. Journal of Biomedical Optics. https://doi.org/10.1117/1.1920212
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.