Epileptic networks studied with EEG‐fMRI
Open accessThe DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Abstract
Summary: It is not easy to determine the location of the cerebral generators and the other brain regions that may be involved at the time of an epileptic spike seen in the scalp EEG. The possibility to combine EEG recording with functional MRI scanning (fMRI) opens the opportunity to uncover the regions of the brain showing changes in metabolism and blood flow in response to epileptic spikes seen in the EEG. These regions are presumably involved in the abnormal neuronal activity at the origin of epileptic discharges. This paper reviews the methodology involved in performing such studies, including the special techniques required for recording the EEG inside the scanner and the statistical issues in analyzing the fMRI signal. We then discuss the results obtained in patients with different types of focal epileptic disorders and in patients with primary generalized epilepsy. The results in general indicate that interictal epileptic discharges may affect brain areas well beyond the presumed region in which they are generated. The noninvasive nature of this method opens new horizons in the investigation of brain regions involved and affected by epileptic discharges.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A default mode of brain function
Raichle, M. E., MacLeod, A. M., Snyder, A. Z., Powers, W. J., Gusnard, D. A., & Shulman, G. L. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.98.2.676 · Cited by 12,190 · cited 2×
“6), in a pattern very similar to that seen in the “default” state of the brain hypothesized by Raichle and collaborators (Raichle et al., 2001; Laufs et al., 2003).”
BackgroundResultDynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212 · cited 1×
“This change can be measured through the Blood Oxygen Level Dependent (BOLD) effect (Kwong et al., 1992; Ogawa et al., 1992). fMRI is mostly used in the study of sensory, motor, and cognitive functions, where the experimental condition differs from the control condition in a way that is controlled…”
MethodMovement‐Related effects in fMRI time‐series
Friston, K. J., Williams, S., Howard, R., Frackowiak, R. S. J., & Turner, R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350312 · Cited by 3,774 · cited 2×
“motion correction as regressors in the statistical analysis (Friston et al., 1996; Salek-Haddadi et al., 2003).”
MethodInterplay between Cortical Spreading Depolarization and Seizures
Kramer, D. R., Fujii, T., Ohiorhenuan, I., & Liu, C. Y. (2017) · Stereotactic and Functional Neurosurgery · doi:10.1159/000452841 · Cited by 3,696
Ogawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681 · cited 2×
“This change can be measured through the Blood Oxygen Level Dependent (BOLD) effect (Kwong et al., 1992; Ogawa et al., 1992). fMRI is mostly used in the study of sensory, motor, and cognitive functions, where the experimental condition differs from the control condition in a way that is controlled…”
MethodAn Energy Budget for Signaling in the Grey Matter of the Brain
Attwell, D., & Laughlin, S. B. (2001) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200110000-00001 · Cited by 3,543 · cited 1×
“Increases in postsynaptic activity, whether excitatory or inhibitory, result in an increase in oxidative metabolism (Attwell & Laughlin, 2001) and eventually in an increase in the BOLD signal.”
BackgroundAnalysis of fMRI Time-Series Revisited
Friston, K. J., Holmes, A. P., Poline, J.-B., Grasby, P. J., Williams, S. C. R., Frackowiak, R. S. J., & Turner, R. (1995) · NeuroImage · doi:10.1006/nimg.1995.1007 · Cited by 2,502 · cited 14×
“Friston KJ, Williams S, Howard R, Frackowiak RS, Turner R. (1996) Movement-related effects in fMRI time-series.”
MethodInfluentialAnalysis of fMRI Time-Series Revisited—Again
Worsley, K. J., & Friston, K. J. (1995) · NeuroImage · doi:10.1006/nimg.1995.1023 · Cited by 2,185 · cited 1×
“In event-related fMRI (Josephs et al., 1998), the statistical methods most widely used are probably those developed by Worsley and Friston (Friston et al., 1995; Worsley & Friston, 1995; Worsley et al., 2002).”
MethodEvent-Related fMRI: Characterizing Differential Responses
Friston, K. J., Fletcher, P., Josephs, O., Holmes, A., Rugg, M. D., & Turner, R. (1998) · NeuroImage · doi:10.1006/nimg.1997.0306 · Cited by 2,029 · cited 2×
“Some approaches do not rely on the linear assumption, such as that presented by Friston et al. (1998b).”
BackgroundDeconvolution of Impulse Response in Event-Related BOLD fMRI1
Glover, G. H. (1999) · NeuroImage · doi:10.1006/nimg.1998.0419 · Cited by 1,386 · cited 1×
“The simplest uses a standard HRF, which is the measured response to a brief stimulus, such as an auditory tone (Glover, 1999).”
Method
Cited by
BOLD correlates of EEG topography reveal rapid resting-state network dynamics
Britz, J., Van De Ville, D., & Michel, C. M. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.02.052 · Cited by 1,070
High-frequency oscillations (HFOs) in clinical epilepsy
Jacobs, J., Staba, R., Asano, E., Otsubo, H., Wu, J. Y., Zijlmans, M., Mohamed, I., Kahane, P., Dubeau, F., Navarro, V., et al. (2012) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2012.03.001 · Cited by 443
Self-citationFunctional connectivity under six anesthesia protocols and the awake condition in rat brain
Paasonen, J., Stenroos, P., Salo, R. A., Kiviniemi, V., & Gröhn, O. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.01.014 · Cited by 295
Evolving functional network properties and synchronizability during human epileptic seizures
Schindler, K. A., Bialonski, S., Horstmann, M.-T., Elger, C. E., & Lehnertz, K. (2008) · Chaos: An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.2966112 · Cited by 257
Synchronization phenomena in human epileptic brain networks
Lehnertz, K., Bialonski, S., Horstmann, M.-T., Krug, D., Rothkegel, A., Staniek, M., & Wagner, T. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.05.015 · Cited by 249
Transfer Function between EEG and BOLD Signals of Epileptic Activity
Leite, M., Leal, A., & Figueiredo, P. (2013) · Frontiers in Neurology · doi:10.3389/fneur.2013.00001 · Cited by 234
“One factor contributing to this state of affairs is the lack of sensitivity in the identification of hemodynamic changes associated with the EEG epileptiform discharges in a significant number of studies (Aghakhani et al., 2006; Salek-Haddadi et al., 2006; Gotman, 2008; Grouiller et al., 2011).”
BackgroundAdvances in MRI for 'cryptogenic' epilepsies
Bernasconi, A., Bernasconi, N., Bernhardt, B. C., & Schrader, D. (2011) · Nature Reviews Neurology · doi:10.1038/nrneurol.2010.199 · Cited by 233
Grouiller, F., Thornton, R. C., Groening, K., Spinelli, L., Duncan, J. S., Schaller, K., Siniatchkin, M., Lemieux, L., Seeck, M., Michel, C. M., et al. (2011) · Brain · doi:10.1093/brain/awr156 · Cited by 199
Horstmann, M.-T., Bialonski, S., Noennig, N., Mai, H., Prusseit, J., Wellmer, J., Hinrichs, H., & Lehnertz, K. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.10.013 · Cited by 194
High-frequency Oscillations and Other Electrophysiological Biomarkers of Epilepsy: Clinical Studies
Worrell, G., & Gotman, J. (2011) · Biomarkers in Medicine · doi:10.2217/bmm.11.74 · Cited by 181
Self-citationWidespread epileptic networks in focal epilepsies: EEG‐fMRI study
Fahoum, F., Lopes, R., Pittau, F., Dubeau, F., & Gotman, J. (2012) · Epilepsia · doi:10.1111/j.1528-1167.2012.03533.x · Cited by 170
“EEG-fMRI has become a valuable tool in the presurgical evaluation of patients with pharmacoresistant epilepsy and to study epileptic networks (Zijlmans et al., 2007; Gotman, 2008; Thornton et al., 2010).”
Self-citationFunctional imaging of seizures and epilepsy: evolution from zones to networks
Laufs, H. (2012) · Current Opinion in Neurology · doi:10.1097/wco.0b013e3283515db9 · Cited by 164
Lu, Y., Yang, L., Worrell, G. A., & He, B. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2011.11.007 · Cited by 98
Wearable OPM-MEG: a changing landscape for epilepsy
Pedersen, M., Abbott, D. F., & Jackson, G. D. (2022) · Epilepsia · doi:10.1111/epi.17368 · Cited by 68
Metadata
- Authors
- Gotman, J.
- Venue
- Epilepsia
- Publisher
- Wiley
- Published
- 2008-02-26
- Volume
- 49
- Issue
- s3
- Pages
- 42-51
- ISSN
- 0013-9580 (ISSN-L)
- 1528-1167
- OpenAlex
- W2028602759
- Cited by
- 216
- References
- 62
- FWCI
- 12.54
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.