Electrical source imaging for presurgical focus localization in epilepsy patients with normal MRI
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Summary: Purpose: Patients with magnetic resonance (MR)–negative focal epilepsy (MRN‐E) have less favorable surgical outcomes (between 40% and 70%) compared to those in whom an MRI lesion guides the site of surgical intervention (60–90%). Patients with extratemporal MRN‐E have the worst outcome (around 50% chance of seizure freedom). We studied whether electroencephalography (EEG) source imaging (ESI) of interictal epileptic activity can contribute to the identification of the epileptic focus in patients with normal MRI. Methods: We carried out ESI in 10 operated patients with nonlesional MRI and a postsurgical follow‐up of at least 1 year. Five of the 10 patients had extratemporal lobe epilepsy. Evaluation comprised surface and intracranial EEG monitoring of ictal and interictal events, structural MRI, [18 F]fluorodeoxyglucose positron emission tomography (FDG‐PET), ictal and interictal perfusion single photon emission computed tomography (SPECT) scans. Eight of the 10 patients also underwent intracranial monitoring. Results: ESI correctly localized the epileptic focus within the resection margins in 8 of 10 patients, 9 of whom experienced favorable postsurgical outcomes. Discussion: The results highlight the diagnostic value of ESI and encourage broadening its application to patients with MRN‐E. If the surface EEG contains fairly localized spikes, ESI contributes to the presurgical decision process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spherical splines for scalp potential and current density mapping
Perrin, F., Pernier, J., Bertrand, O., & Echallier, J. F. (1989) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(89)90180-6 · Cited by 2,706 · cited 1×
“In the remaining single spike epochs, electrodes containing artifacts were interpolated using a three-dimensional spline interpolation algorithm (Perrin et al., 1989) to keep the number of electrodes the same for all epochs.”
MethodEpileptic source localization with high density EEG: how many electrodes are needed?
Lantz, G., Grave de Peralta, R., Spinelli, L., Seeck, M., & Michel, C. M. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00337-1 · Cited by 413
Self-citationIctal source analysis: Localization and imaging of causal interactions in humans
Ding, L., Worrell, G. A., Lagerlund, T. D., & He, B. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.09.042 · Cited by 183 · cited 2×
“Its clinical utility has been demonstrated mainly in lesional epilepsy, where it localized correctly in 74–90% of all cases (Michel et al., 2004a; Sperli et al., 2006; Ding et al., 2007a; Leijten & Huiskamp, 2008; Brodbeck et al., 2009).”
BackgroundMethod
Cited by
Towards the utilization of EEG as a brain imaging tool
Michel, C. M., & Murray, M. M. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.12.039 · Cited by 738
Self-citationEEG Source Imaging: A Practical Review of the Analysis Steps
Michel, C. M., & Brunet, D. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00325 · Cited by 705
Self-citationThe standardized EEG electrode array of the IFCN
Seeck, M., Koessler, L., Bast, T., Leijten, F., Michel, C., Baumgartner, C., He, B., & Beniczky, S. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.06.254 · Cited by 489
Self-citationElectroencephalographic source imaging: a prospective study of 152 operated epileptic patients
Brodbeck, V., Spinelli, L., Lascano, A. M., Wissmeier, M., Vargas, M.-I., Vulliemoz, S., Pollo, C., Schaller, K., Michel, C. M., & Seeck, M. (2011) · Brain · doi:10.1093/brain/awr243 · Cited by 427
“Supplementary Table 1 gives the characteristics of each of the 152 patients.”
BackgroundMethodSelf-citationMRI ‐negative temporal lobe epilepsy—What do we know?
Muhlhofer, W., Tan, Y., Mueller, S. G., & Knowlton, R. (2017) · Epilepsia · doi:10.1111/epi.13699 · Cited by 209
Metadata
- Authors
- Brodbeck, V., Spinelli, L., Lascano, A. M., Pollo, C., Schaller, K., Vargas, M. I., Wissmeyer, M., Michel, C. M., & Seeck, M.
- Venue
- Epilepsia
- Publisher
- Wiley
- Published
- 2010-04
- Volume
- 51
- Issue
- 4
- Pages
- 583-591
- ISSN
- 0013-9580 (ISSN-L)
- 1528-1167
- OpenAlex
- W2002145791
- Cited by
- 128
- References
- 3
- FWCI
- 6.78
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrical source imaging for presurgical focus localization in epilepsy patients with normal MRI. https://app.cochat.ai/papers/10.1111/j.1528-1167.2010.02521.x
- The paper
- Brodbeck, V., Spinelli, L., Lascano, A. M., Pollo, C., Schaller, K., Vargas, M. I., Wissmeyer, M., Michel, C. M., & Seeck, M. (2010). Electrical source imaging for presurgical focus localization in epilepsy patients with normal MRI. Epilepsia. https://doi.org/10.1111/j.1528-1167.2010.02521.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.