Prospective observation of CAD/CAM titanium ceramic single crowns: A three-year follow up
The DOI matches its Crossref record; 43 of the 46 references it cites were found in a registry or an index.
Abstract
Statement of problem Computer-aided design/computer-aided manufacturing (CAD/CAM) titanium ceramic restorations were developed with the potential for replacing expensive, high noble metal ceramic restorations. However, there is a lack of information about the clinical performance of CAD/CAM titanium ceramic single crowns.Purpose The purpose of this study was to evaluate CAD/CAM titanium ceramic single crowns after 3 years in function.Material and methods A total of 41 crowns were fabricated for 21 patients. The titanium copings were CAD/CAM milled (Everest CAD/CAM system) with an even thickness of 0.5 mm, and low-fusing veneering porcelain (Vita Titanium Porcelain) was added incrementally. The crowns were cemented using zinc phosphate cement after confirming that there were no mechanical and biological complications. The patients were recalled at 12, 24, and 36 months after cementation to examine the presence of any complications and measure periodontal parameters such as probing depth (PD), bleeding on probing (BOP), and plaque index (PI). The success and survival rates were estimated using the Kaplan-Meier analysis.Results The success rate of CAD/CAM titanium ceramic crowns with regard to mechanical complications was 82.3% (95% confidence interval: 71.2% to 95.1%). The cumulative survival rate of the crowns was 94.9% (95% confidence interval: 88.3% to 100%) after 3 years. No biological complications were observed. At the end of the follow up, PD was 2.93 mm, percentile of surface with BOP was 29.2, and PI was 0.31.Conclusions The clinical performances of the CAD/CAM titanium ceramic crowns for 3 years were acceptable, with no biologic complications and a high cumulative survival rate.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Periodontal Disease in Pregnancy II. Correlation Between Oral Hygiene and Periodontal Condition
Silness, J., & Löe, H. (1964) · Acta Odontologica Scandinavica · doi:10.3109/00016356408993968 · Cited by 7,932
Moher, D., Schulz, K. F., & Altman, D. G. (2001) · The Lancet · doi:10.1016/s0140-6736(00)04337-3 · Cited by 5,373
Carranza's Clinical Periodontology
Newman, H. H. T. E. B. M. G. (2001) · Medical Entomology and Zoology · Cited by 837
Tan, K., Pjetursson, B. E., Lang, N. P., & Chan, E. S. Y. (2004) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2004.01119.x · Cited by 769
Sailer, I., Pjetursson, B. E., Zwahlen, M., & Hämmerle, C. H. F. (2007) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2007.01468.x · Cited by 724
Pjetursson, B. E., Tan, K., Lang, N. P., Brägger, U., Egger, M., & Zwahlen, M. (2004) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2004.01117.x · Cited by 486
Titanium and titanium alloys as dental materials.
Lautenschlager, E. P., & Monaghan, P. (1993) · PubMed · Cited by 474
Pjetursson, B. E., Sailer, I., Zwahlen, M., & Hämmerle, C. H. F. (2007) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2007.01467.x · Cited by 454
Periodontal probing: What does it mean?
Listgarten, M. A. (1980) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.1980.tb01960.x · Cited by 435
Titanium for prosthodontic applications: a review of the literature.
Wang, R. R., & Fenton, A. H. (1996) · PubMed · Cited by 374
Research works printed but not linked: 1
- Persson, 1995, The accuracy of a high-precision digitizer for CAD/CAM of crowns, J Prosthet Dent, 74, 223, 10.1016/s0022-3913(05)80127-1 · DOI
Cited by
Dental prostheses and tooth‐related factors
Ercoli, C., & Caton, J. G. (2018) · Journal of Periodontology · doi:10.1002/jper.16-0569 · Cited by 105
Clinical outcome of single porcelain-fused-to-zirconium dioxide crowns: A systematic review
Takeichi, T., Katsoulis, J., & Blatz, M. B. (2013) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2013.09.015 · Cited by 76
Dental prostheses and tooth‐related factors
Ercoli, C., & Caton, J. G. (2018) · Journal of Clinical Periodontology · doi:10.1111/jcpe.12950 · Cited by 67
Revolutionizing Restorative Dentistry: An Overview
Prithviraj, D. R., Bhalla, H. K., Vashisht, R., Sounderraj, K., & Prithvi, S. (2014) · The Journal of Indian Prosthodontic Society · doi:10.1007/s13191-014-0351-5 · Cited by 49
“[11] evaluated CAD/CAM titanium ceramic single crowns after 3 years in function.”
MethodOzer, F., Mante, F. K., Chiche, G., Saleh, N., Takeichi, T., & Blatz, M. B. (2014) · PubMed · doi:10.3290/j.qi.a30768 · Cited by 45
Metadata
- Authors
- Boeckler, A. F., Lee, H., Stadler, A., & Setz, J. M.
- Affiliations
- Martin Luther University Halle-Wittenberg (DE)
- Louisiana State University (US)
- Corresponding author
- Boeckler, Arne F.
- Venue
- The Journal of Prosthetic Dentistry
- Publisher
- Elsevier BV
- Published
- 2009-11
- Volume
- 102
- Issue
- 5
- Pages
- 290-297
- ISSN
- 0022-3913 (ISSN-L)
- OpenAlex
- W1992260385
- Cited by
- 31
- References
- 46
- Citations by year
- 2026: 1 · 2025: 1 · 2023: 2 · 2022: 2 · 2019: 1 · 2018: 3 · 2016: 3 · 2015: 2 · 2014: 7 · 2013: 3 · 2012: 3
- FWCI
- 2.45
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Journal of Prosthetic Dentistry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Dentistry › General Dentistry › Dental materials and restorations
- Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes
- Health Sciences › Dentistry › Oral Surgery › Endodontics and Root Canal Treatments
- Keywords
- single crowns, mechanical complications, periodontal parameters, zinc phosphate cement, clinical performance
- MeSH terms
- Dental Abutments, Adult, Aged, Cementation, Crowns, Dental Materials, Dental Plaque Index, Dental Porcelain, Dental Veneers, Female, Follow-Up Studies, Humans, Male, Middle Aged, Periodontal Index, Periodontal Pocket, Prospective Studies, Titanium, Zinc Phosphate Cement, Survival Analysis, Radiography, Bitewing, Treatment Outcome, Computer-Aided Design, Dental Prosthesis Design, Dental Prosthesis Repair, Tooth Preparation, Prosthodontic, Dental Restoration Failure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prospective observation of CAD/CAM titanium ceramic single crowns: A three-year follow up. https://app.cochat.ai/papers/10.1016/s0022-3913(09)60176-1
- The paper
- Boeckler, A. F., Lee, H., Stadler, A., & Setz, J. M. (2009). Prospective observation of CAD/CAM titanium ceramic single crowns: A three-year follow up. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/s0022-3913(09)60176-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.