The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Paucity of studies to support that abnormal coagulation test results predict bleeding in the setting of invasive procedures: an evidence‐based review
Abstract
BACKGROUND: The literature was systematically reviewed to determine whether a prolonged prothrombin time or elevated international normalized ratio predicts bleeding during invasive diagnostic procedures. STUDY DESIGN AND METHODS: MEDLINE and CENTRAL were searched through August 2004, with no language restriction, and reference lists were reviewed. For inclusion, articles must have reported on bleeding in more than five patients with abnormal test results undergoing diagnostic procedures. RESULTS: One trial and 24 observational studies were included. In 2 studies of bronchoscopy, the bleeding rates were similar among those with normal and abnormal tests, with wide confidence intervals (CIs) around the risk differences. During central vein cannulation (3 studies), bleeding rates among those with abnormal tests was unlikely to exceed 2.3 percent. The largest of 3 studies of arteriography found equivalent bleeding rates in patients with and without abnormal tests (risk difference, 0%; 95% CI, −3% to 2%). In the 3 studies of liver biopsy with plugging, bleeding rates were 0, 4, and 5 percent with the upper bounds of the CI as high as 17 percent. In the largest study of transjugular biopsy, the bleeding rate was 1.5 percent (95% CI, 0.3%‐4%) in patients with abnormal tests. The highest bleeding rate in the 3 studies of percutaneous liver biopsy was 5.3 percent (95% CI, 1%‐13%), similar to the rate in patients with normal test results. CONCLUSION: There is insufficient evidence to conclude that abnormal test results predict bleeding. Randomized controlled trials should be performed to provide stronger evidence for clinical decision making regarding preprocedure transfusion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stehling, L. C., Doherty, D. C., Faust, R. J., Greenburg, A. G., Harrison, C. R., Landers, D. F., Laros, R. K., Pierce, E. C., Prust, R. S., Rosenberg, A. D., et al. (1996) · PubMed · Cited by 894
Guidelines for the use of fresh‐frozen plasma, cryoprecipitate and cryosupernatant
British Committee for Standards in Haematology, B. T. T. F. (. D., O'Shaughnessy, D. F., Atterbury, C., Bolton Maggs, P., Murphy, M., Thomas, D., Yates, S., & Williamson, L. M. (2004) · British Journal of Haematology · doi:10.1111/j.1365-2141.2004.04972.x · Cited by 840
Does blinding of readers affect the results of meta-analyses?
Berlin, J. A. (1997) · The Lancet · doi:10.1016/s0140-6736(05)62352-5 · Cited by 478
Is fresh frozen plasma clinically effective? A systematic review of randomized controlled trials
Stanworth, S. J., Brunskill, S. J., Hyde, C. J., McClelland, D. B. L., & Murphy, M. F. (2004) · British Journal of Haematology · doi:10.1111/j.1365-2141.2004.04973.x · Cited by 422
Bleeding after liver biopsy does not correlate with indices of peripheral coagulation
Ewe, K. (1981) · Digestive Diseases and Sciences · doi:10.1007/bf01313579 · Cited by 354
McVay, P. A., & Toy, P. T. C. Y. (1991) · Transfusion · doi:10.1046/j.1537-2995.1991.31291142949.x · Cited by 269
Therapie des aktiven Morbus Crohn mit dem Boswellia-serrata-Extrakt H 15
Gerhardt, H., Seifert, F., Buvari, P., Vogelsang, H., & Repges, R. (2001) · Zeitschrift für Gastroenterologie · doi:10.1055/s-2001-10708 · Cited by 223
Instruments for Assessing the Quality of Drug Studies Published in the Medical Literature
Cho, M. K. (1994) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1994.03520020027007 · Cited by 180
Lack of Increased Bleeding after Liver Biopsy in Patients with Mild Hemostatic Abnormalities
Mcvay, P. A., Toy, P. T. C. Y., & Carbone, A. (1990) · American Journal of Clinical Pathology · doi:10.1093/ajcp/94.6.747 · Cited by 176
Sawyerr, A. M., McCormick, P. A., Tennyson, G. S., Chin, J., Dick, R., Scheuer, P. J., Burroughs, A. K., & McIntyre, N. (1993) · Journal of Hepatology · doi:10.1016/s0168-8278(05)80525-2 · Cited by 116
Smith, T. P., Presson, T. L., Heneghan, M. A., et al. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.180.1.1800167 · Cited by 81
Riley, S., Irving, H. C., Axon, A. T. R., et al. (1984) · The Lancet · doi:10.1016/s0140-6736(84)92910-6 · Cited by 65
Transjugular liver biopsy: assessment of safety and efficacy of the Quick-Core biopsy needle
Bruzzi, J. F., O'Connell, M. J., Thakore, H., O’Keane, C., Crowe, S. F., & Murray, J. G. (2002) · Abdominal Imaging · doi:10.1007/s00261-002-0020-8 · Cited by 46
Thromboelastography for the prediction of bleeding after transplant renal biopsy.
Davis, C. L., & Chandler, W. L. (1995) · Journal of the American Society of Nephrology · doi:10.1681/asn.v641250 · Cited by 33
Transjugular liver biopsy: modified Ross transseptal needle versus Quick-core biopsy needle
Choo, S., Do, Y. S., Park, K. B., Kim, S. H., Han, Y., & Choo, I. W. (2000) · Abdominal Imaging · doi:10.1007/s002610000043 · Cited by 24
Cited by
Rockey, D. C., Caldwell, S. H., Goodman, Z. D., Nelson, R. C., & Smith, A. D. (2009) · Hepatology · doi:10.1002/hep.22742 · Cited by 1,997
The Coagulopathy of Chronic Liver Disease
Tripodi, A., & Mannucci, P. M. (2011) · New England Journal of Medicine · doi:10.1056/nejmra1011170 · Cited by 1,342
ERCP-related adverse events: European Society of Gastrointestinal Endoscopy (ESGE) Guideline
Dumonceau, J.-M., Kapral, C., Aabakken, L., Papanikolaou, I. S., Tringali, A., Vanbiervliet, G., Beyna, T., Dinis-Ribeiro, M., Hritz, I., Mariani, A., et al. (2020) · Endoscopy · doi:10.1055/a-1075-4080 · Cited by 934
Management of severe perioperative bleeding: Guidelines from the European Society of Anaesthesiology
Kozek-Langenecker, S. A., Afshari, A., Albaladejo, P., Santullano, C. A. A., De Robertis, E., Filipescu, D. C., Fries, D., Görlinger, K., Haas, T., Imberger, G., et al. (2013) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e32835f4d5b · Cited by 909
Patel, I. J., Davidson, J. C., Nikolic, B., Salazar, G. M., Schwartzberg, M. S., Walker, T. G., & Saad, W. A. (2012) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2012.02.012 · Cited by 752
Metadata
- Authors
- Segal, J. B., Dzik, W. H., & Transfusion Medicine/Hemostasis Clinical Trials Network
- Venue
- Transfusion
- Publisher
- Wiley
- Published
- 2005-07-22
- Volume
- 45
- Issue
- 9
- Pages
- 1413-1425
- ISSN
- 0041-1132 (ISSN-L)
- 1537-2995
- OpenAlex
- W2146292166
- Cited by
- 663
- References
- 16
- FWCI
- 10.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.