Residential Air Exchange Rates in the United States: Empirical and Estimated Parametric Distributions by Season and Climatic Region
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The purpose of this paper is to undertake a statistical analysis to specify empirical distributions and to estimate univariate parametric probability distributions for air exchange rates for residential structures in the United States. To achieve this goal, we used data compiled by the Brookhaven National Laboratory using a method known as the perfluorocarbon tracer (PFT) technique. While these data are not fully representative of all areas of the country or all housing types, they are judged to be by far the best available. The analysis is characterized by four key points: the use of data for 2,844 households; a four‐region breakdown based on heating degree days, a best available measure of climatic factors affecting air exchange rates; estimation of lognormal distributions as well as provision of empirical (frequency) distributions; and provision of these distributions for all of the data, for the data segmented by the four regions, for the data segmented by the four seasons, and for the data segmented by a 16 region by season breakdown. Except in a few cases, primarily for small sample sizes, air exchange rates were found to be well fit by lognormal distributions (adjusted R 2 0.95). The empirical or lognormal distributions may be used in indoor air models or as input variables for probabilistic human health risk assessments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Suggestion for Using Powerful and Informative Tests of Normality
D'agostino, R. B., Belanger, A., & D'agostino, R. B. (1990) · The American Statistician · doi:10.2307/2684359 · Cited by 1,809
A Suggestion for Using Powerful and Informative Tests of Normality
D'agostino, R. B., Belanger, A., & D'agostino, R. B. (1990) · The American Statistician · doi:10.1080/00031305.1990.10475751 · Cited by 1,804
Tracer-gas techniques for measuring ventilation in a single zone
Sherman, M. H. (1990) · Building and Environment · doi:10.1016/0360-1323(90)90010-o · Cited by 291
Statistical Methods for Environmental Pollution Monitoring
Gilbert, R. O. (2017) · University of North Texas Digital Library (University of North Texas) · Cited by 286
Dietz, R., Goodrich, R., Cote, E., & Wieser, R. (1986) · Measured Air Leakage of Buildings · doi:10.1520/stp19649s · Cited by 108
Cited by
Indoor air pollution in developing countries and acute lower respiratory infections in children
Smith, K. R. (2000) · Thorax · doi:10.1136/thorax.55.6.518 · Cited by 947
Toward Understanding the Risk of Secondary Airborne Infection: Emission of Respirable Pathogens
Nicas, M., Nazaroff, W. W., & Hubbard, A. (2005) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620590918466 · Cited by 867
“5 ach is a typical residential air exchange rate.(31) Airborne M.”
BackgroundSemivolatile organic compounds in indoor environments
Weschler, C. J., & Nazaroff, W. W. (2008) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.09.052 · Cited by 850
Cleaning products and air fresheners: exposure to primary and secondary air pollutants
Nazaroff, W. W., & Weschler, C. J. (2004) · Atmospheric Environment · doi:10.1016/j.atmosenv.2004.02.040 · Cited by 846
Ozone in Indoor Environments: Concentration and Chemistry
WESCHLER, C. J. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004269.x · Cited by 758
Nazaroff, W. W. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00286.x · Cited by 639
Indoor particulate matter of outdoor origin: Importance of size-dependent removal mechanisms
Riley, W. J., McKone, T. E., Lai, A. C. K., & Nazaroff, W. W. (2002) · Environmental Science & Technology · doi:10.1021/es010723y · Cited by 417
Morawska, L., Ayoko, G. A., Bae, G. N., Buonanno, G., Chao, C. Y. H., Clifford, S., Fu, S. C., Hänninen, O., He, C., Isaxon, C., et al. (2017) · Environment International · doi:10.1016/j.envint.2017.07.025 · Cited by 374
Indoor secondary pollutants from cleaning product and air freshener use in the presence of ozone
Singer, B. C., Coleman, B. K., Destaillats, H., Hodgson, A. T., Lunden, M. M., Weschler, C. J., & Nazaroff, W. W. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.06.005 · Cited by 330
Human Breath Emissions of VOCs
Fenske, J. D., & Paulson, S. E. (1999) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1999.10463831 · Cited by 302
Ozone and limonene in indoor air: a source of submicron particle exposure.
Wainman, T., Zhang, J., Weschler, C. J., & Lioy, P. J. (2000) · Environmental Health Perspectives · doi:10.1289/ehp.001081139 · Cited by 274
Thirdhand Smoke: New Evidence, Challenges, and Future Directions
Jacob, P., Benowitz, N. L., Destaillats, H., Gundel, L., Hang, B., Martins-Green, M., Matt, G. E., Quintana, P. J. E., Samet, J. M., Schick, S. F., et al. (2017) · Chemical Research in Toxicology · doi:10.1021/acs.chemrestox.6b00343 · Cited by 273
WALLACE, L. A., EMMERICH, S. J., & HOWARD-REED, C. (2002) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500229 · Cited by 260
“Air change rates have been measured in several thousand homes in the US (Murray and Burmaster, 1995), but most of these were one- time measurements made over short periods of 12 h to several weeks, making it impossible to determine the effects on air change rates of weather conditions and homeowner behavior such as wi…”
BackgroundA new detailed chemical model for indoor air pollution
Carslaw, N. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.09.038 · Cited by 224
“67 ach , a more realistic value for winter (Murray and Burmaster, 1995).”
BackgroundA population exposure model for particulate matter: case study results for PM2.5 in Philadelphia, PA
BURKE, J. M., ZUFALL, M. J., & ÖZKAYNAK, H. (2001) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500188 · Cited by 223
The Effect of Opening Windows on Air Change Rates in Two Homes
Howard-Reed, C., Wallace, L. A., & Ott, W. R. (2002) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2002.10470775 · Cited by 218
Ultrafine particle removal and generation by portable air cleaners
Waring, M. S., Siegel, J. A., & Corsi, R. L. (2008) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.02.011 · Cited by 217
“where the air exchange rate, l, was again assumed as 0.5 h� 1 ( Murray and Burmaster, 1995 ), and the”
MethodInfluentialVentilation rates in the bedrooms of 500 Danish children
Bekö, G., Lund, T., Nors, F., Toftum, J., & Clausen, G. (2010) · Building and Environment · doi:10.1016/j.buildenv.2010.04.014 · Cited by 209
Allen, R., Larson, T., Sheppard, L., Wallace, L., & Liu, L.-J. S. (2003) · Environmental Science & Technology · doi:10.1021/es021007e · Cited by 205
Influenza Virus Infectivity Is Retained in Aerosols and Droplets Independent of Relative Humidity
Kormuth, K. A., Lin, K., Prussin, A. J., Vejerano, E. P., Tiwari, A. J., Cox, S. S., Myerburg, M. M., Lakdawala, S. S., & Marr, L. C. (2018) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiy221 · Cited by 205
Silver Nanoparticles and Total Aerosols Emitted by Nanotechnology-Related Consumer Spray Products
Quadros, M. E., & Marr, L. C. (2011) · Environmental Science & Technology · doi:10.1021/es202770m · Cited by 201
The atmospheric chemistry of indoor environments
Abbatt, J. P. D., & Wang, C. (2020) · Environmental Science: Processes & Impacts · doi:10.1039/c9em00386j · Cited by 200
Analyzing a database of residential air leakage in the United States
Chan, W. R., Nazaroff, W. W., Price, P. N., Sohn, M. D., & Gadgil, A. J. (2005) · Atmospheric Environment · doi:10.1016/j.atmosenv.2005.01.062 · Cited by 199
Relative Contributions of Four Exposure Pathways to Influenza Infection Risk
Nicas, M., & Jones, R. M. (2009) · Risk Analysis · doi:10.1111/j.1539-6924.2009.01253.x · Cited by 190
“homes.(19) The assigned surface area immediately near the infector is 104 cm2, 90% of which is textile (e.”
BackgroundFundamentals of Risk Analysis and Risk Management
(1996) · CRC Press eBooks · doi:10.1201/9781439821978 · Cited by 186
“Residential air exchange rate data have been summarized by Pandian et al. (1993) and refined by Murray and Burmaster (1995).”
Ozone Interactions with Carpet: Secondary Emissions of Aldehydes
Morrison, G. C., & Nazaroff, W. W. (2002) · Environmental Science & Technology · doi:10.1021/es0113089 · Cited by 185
Infiltration of forest fire and residential wood smoke: an evaluation of air cleaner effectiveness
Barn, P., Larson, T., Noullett, M., Kennedy, S., Copes, R., & Brauer, M. (2008) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jes.7500640 · Cited by 166
“The lower infiltration measured in this study relative to others was also supported by our estimation of air-exchange rates that are at the low end of distributions computed for large residential samples in the US (Murray and Burmaster, 1995; Pandian et al., 1998; Chan et al., 2005).”
ResultConcentrations and Fate of Decamethylcyclopentasiloxane (D5) in the Atmosphere
McLachlan, M. S., Kierkegaard, A., Hansen, K. M., van Egmond, R., Christensen, J. H., & Skjøth, C. A. (2010) · Environmental Science & Technology · doi:10.1021/es100411w · Cited by 166
Using Sulfur as a Tracer of Outdoor Fine Particulate Matter
Sarnat, J. A., Long, C. M., Koutrakis, P., Coull, B. A., Schwartz, J., & Suh, H. H. (2002) · Environmental Science & Technology · doi:10.1021/es025796b · Cited by 163
Residential air‐change rates: A critical review
Nazaroff, W. W. (2021) · Indoor Air · doi:10.1111/ina.12785 · Cited by 161
Air infiltration rate distributions of residences in Beijing
Shi, S., Chen, C., & Zhao, B. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.05.027 · Cited by 159
Bhangar, S., Mullen, N. A., Hering, S. V., Kreisberg, N. M., & Nazaroff, W. W. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00689.x · Cited by 158
Yamamoto, N., Shendell, D. G., Winer, A. M., & Zhang, J. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2009.00622.x · Cited by 156
Environmental Impact of Buildings─What Matters?
Heeren, N., Mutel, C. L., Steubing, B., Ostermeyer, Y., Wallbaum, H., & Hellweg, S. (2015) · Environmental Science & Technology · doi:10.1021/acs.est.5b01735 · Cited by 128
Ventilation in public housing: implications for indoor nitrogen dioxide concentrations
Zota, A., Adamkiewicz, G., Levy, J. I., & Spengler, J. D. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2005.00375.x · Cited by 118
A review of air exchange rate models for air pollution exposure assessments
Breen, M. S., Schultz, B. D., Sohn, M. D., Long, T., Langstaff, J., Williams, R., Isaacs, K., Meng, Q. Y., Stallings, C., & Smith, L. (2014) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/jes.2013.30 · Cited by 69
“For US residences, measured AER distributions have been reported by region and season.(24,25) For small to medium size commercial buildings, studies reported AER distributions(26,27) and individual(28) AER measurements with and without mechanical ventilation.”
BackgroundMontoya, L. D., & Hildemann, L. M. (2001) · Atmospheric Environment · doi:10.1016/s1352-2310(00)00379-4 · Cited by 15
Metadata
- Authors
- Murray, D. M., & Burmaster, D. E.
- Venue
- Risk Analysis
- Publisher
- Wiley
- Published
- 1995-08
- Volume
- 15
- Issue
- 4
- Pages
- 459-465
- ISSN
- 0272-4332 (ISSN-L)
- 1539-6924
- OpenAlex
- W2164579856
- Cited by
- 250
- References
- 5
- FWCI
- 2.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.