Electrocardiographically Documented Unnecessary, Spontaneous Shocks in 241 Patients With Implantable Cardioverter Defibrillators
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
The incidence and cause of electrocardiographically documented spontaneous implantuble Cardioverter defibrillator (ICD) discharges for a rhythm other than ventricular tachycardia (VT) or fibrillation (VF) (unnecessary shocks) were determined in 241 patients who underwent ICD implantation between March 1983 and November 1991. During follow‐up of 24 ± 20 months, 54 of 241 patients (22%) received a total of 132 unnecessary ICD shocks confirmed by Holler or telemetry monitoring or stored electrograms (Egs) from the ICD. The rhythm preceding these unnecessary ICD shocks was atrial fibrillation in 30 patients, sinus or supraventricular tachycardia (SVT) in 11 patients, antitachycardia pacing triggered by atrial fibrillation or SVT resulting in VT in 5 patients, nonsustained VT in 3 patients, and normal sinus or pacemaker rhythm in 10 patients. Unnecessary ICD discharges occurred most frequently during the first week after implantation or generator replacement (18 of 54 patients [33%]). Unnecessary ICD discharges could be documented more often by stored Egs in patients with devices with Eg storage capability (Ventritex Cadence(tm), 19 of 54 patients [35%]) than by Holter or telemetry monitoring in patients with devices without Eg storage capabilities (34 of 193 patients [18%], P < 0.01), despite a shorter mean follow‐up duration of 14 ± 9 months versus 26 ± 21 months, respectively. Only six of 54 patients (11%) in whom unnecessary ICD discharges occurred had recurrent unnecessary shocks during 22 ± 20 months of follow‐up after treatment directed at the cause of the first episode or device reprogramming to preclude non‐VT rhythm detection. In conclusion, unnecessary ICD shocks are a frequent complication of ICD therapy occurring in at least 22% of patients. The cause of these shocks is most frequently atrial fibrillation with a rapid ventricular response. The availability of Eg storage capabilities facilitates the diagnosis of the electrical event precipitating inappropriate ICD shocks. Diagnosis of the cause of unnecessary shocks allows for the institution of therapy that may reduce the risk for subsequent events.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Long-term outcome with the automatic implantable cardioverter-defibrillator
Winkle, R. A., Mead, R. H., Ruder, M. A., Gaudiani, V. A., Smith, N. A., Buch, W. S., Schmidt, P., & Shipman, T. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90310-0 · Cited by 719 · cited 1×
“Holter or telemetry monitoring during followup was performed routinely for the following reasons: (1) analysis of rhythms leading to frequent ICD discharges; (2) suspected inappropriate ICD shocks: (3) change of antiarrhythmic therapy because of intolerance or inefficacy; (4) episodes of palpitations, dizziness, or sy…”
MethodKelly, P. A., Cannom, D. S., Garan, H., Mirabal, G. S., Harthorne, J. W., Hurvitz, R. J., Vlahakes, G. J., Jacobs, M. L., Ilvento, J. P., Buckley, M. J., et al. (1988) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(88)90292-6 · Cited by 380 · cited 3×
“^'^ The purpose of this study was: (1) to determine the incidence and cause of spontaneous, ECG documented ICD discharges in the absence of VT or VF in a large patient population; and (2) to contrast the diagnostic yield of Holter and/or telemetry monitoring with that of the information obtainable from analysis of sto…”
BackgroundMethodGabry, M. D., Brodman, R., Johnston, D. R., Frame, R., Kim, S. G., Waspe, L. E., Fisher, J. D., & Furman, S. (1987) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(87)80477-1 · Cited by 151
Hook, B. G., & Marchlinski, F. E. (1991) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(91)90884-c · Cited by 141 · cited 1×
“discharge; and (5) admission to intensive or intermediate care unit, e.”
BackgroundSelf-citationFogoros, R. N., ELSON, J. J., & BONNET, C. A. (1989) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1989.tb06151.x · Cited by 139
Smooth muscle cell proliferation and restenosis after stand alone coronary excimer laser angioplasty
Karsch, K. R., Haase, K. K., Wehrmann, M., Hassenstein, S., & Hanke, H. (1991) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(91)90885-d · Cited by 136
Maloney, J. D., Masterson, M., Khoury, D. S., Trohman, R. G., Wilkoff, B. L., Simmons, T. W., Morant, V. A., & CASTLE, L. W. (1991) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1991.tb05107.x · Cited by 76 · cited 3×
“^'^ The purpose of this study was: (1) to determine the incidence and cause of spontaneous, ECG documented ICD discharges in the absence of VT or VF in a large patient population; and (2) to contrast the diagnostic yield of Holter and/or telemetry monitoring with that of the information obtainable from analysis of sto…”
BackgroundMethodArrhythmias induced by device antitachycardia therapy due to diagnostic nonspecificity
Johnson, N. J., & Marchlinski, F. E. (1991) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(91)90566-r · Cited by 70
Self-citationCallans, D. J., Hook, B. G., & Marchlinski, F. E. (1991) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1991.tb02790.x · Cited by 50
Self-citationBallas, S., RASHIDI, R., MCALISTER, H. F., CORBELLI, R., McCowan, R. J., Wilkoff, B. L., CASTLE, L. W., Morant, V. A., Simmons, T. W., & Maloney, J. D. (1989) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1989.tb01859.x · Cited by 25
Initiation of a sustained ventricular arrhythmia resulting from R wave-synchronous AICD discharge
Gottlieb, C. D., Rosenthal, M., & Marchlinski, F. E. (1988) · American Heart Journal · doi:10.1016/0002-8703(88)90902-7 · Cited by 6
Self-citation
Cited by
Wilkoff, B. L., Fauchier, L., Stiles, M. K., Morillo, C. A., Al-Khatib, S. M., Almendral, J., Aguinaga, L., Berger, R. D., Cuesta, A., Daubert, J. P., et al. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2015.11.018 · Cited by 301
Friedman, P. A., McClelland, R. L., Bamlet, W. R., Acosta, H., Kessler, D., Munger, T. M., Kavesh, N. G., Wood, M., Daoud, E., Massumi, A., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.594531 · Cited by 258
DEISENHOFER, I., KOLB, C., NDREPEPA, G., SCHREIECK, J., KARCH, M., SCHMIEDER, S., ZRENNER, B., & SCHMITT, C. (2001) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2001.00134.x · Cited by 248
“7%) patients, including lead revision or replacement (6), hematoma (1), need for implantation of an additional lead (2), and pneumothorax (1).”
BackgroundWilkoff, B. L., Fauchier, L., Stiles, M. K., Morillo, C. A., Al-Khatib, S. M., Almendral, J., Aguinaga, L., Berger, R. D., Cuesta, A., Daubert, J. P., et al. (2016) · Europace · doi:10.1093/europace/euv411 · Cited by 243
“causes in modern clinical trials.(95,96,117,125,126) This decrease is likely due to differences in both clinical populations and the programming of multiple ICD parameters, including longer detection time and higher rate cut-offs.”
BackgroundRosenqvist, M., Beyer, T., Block, M., den Dulk, K., Minten, J., & Lindemans, F. (1998) · Circulation · doi:10.1161/01.cir.98.7.663 · Cited by 232
“With “shock-only” devices, the incidence of these events during long-term follow-up has ranged between 16% and 21%.(16,17) Fromer et al(18) reported inappropriately detected episodes in 10 of 102 patients with implants during an average follow-up period of 9.”
Background
Metadata
- Authors
- GRIMM, W., FLORES, B. F., & MARCHLINSKI, F. E.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1992-11
- Volume
- 15
- Issue
- 11
- Pages
- 1667-1673
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2041007877
- Cited by
- 242
- References
- 11
- FWCI
- 7.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.