Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 250

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Short‐and Long‐Term Reproducibility of QT, QTc, and QT Dispersion Measurement in Healthy Subjects

KAUTZNER, JOSEF, YI, GANG, CAMM, A. JOHN, MALIK, MAREK·1994·Pacing and Clinical Electrophysiology

Abstract

The study investigated interobserver and intrasubject reproducibility of QT interval duration and dispersion measured in standard 12‐lead ECGs recorded at 25 mm/sec. Twenty‐eight healthy volunteers were studied. Each undenvent four ECG recordings, which were performed 1, 7, and 30 days apart. Two independent observers analyzed each ECG record. In each lead with a distinguishable T wave pattern, the RR interval, Q‐peak of T interval, and Q‐end of T interval were measured using a digitizing board with a 0.1‐mm resolution. From each recording the following measures were derived: the maximum, minimum, and mean QT interval; maximum, minimum, and mean heart rate corrected QT interval (QTc); QT and QTc dispersion (the difference between the maximum and minimum QT interval among the 12 leads); and adjusted QT and QTc dispersion (dispersion divided by the square root of the number of leads measured). The interobserver and short‐term (1 day) and long‐term (1 week and 1 month) reproducibility of individual indices was assessed by computing the relative errors and comparing them by a standard sign test. In addition, the distributions of maximum and minimum QTc values among electrocardiographicleads, and the differences between QT‐end and QT‐peak based measurements were investigated. The results showed that: (1) the measurement of the QT interval from standard ECG recordings is feasible and not operator dependent (interobserver relative error <4%); (2) the duration of the QT interval in healthy volunteers is stable and its short‐ and long‐term reproducibility is high (intrasubject relative error < 6%); (3) parameters that characterize dispersion of the QT interval in the 12‐lead ECG are highly nonreproducible, both between subsequent recording (relative error of 25%–35%) and between observers (relative errar 28%–33%), the reproducibility of QT dispersion is significantly lower than that of QT duration (P < 0.01); and (4) the duration of the entire QT interval correlates only weakly with the duration of the Q‐peak of T interval.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.1994.tb01435.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 250

Metadata

Authors
KAUTZNER, J., YI, G., CAMM, A. J., & MALIK, M.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
1994-05
Volume
17
Issue
5
Pages
928-937
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W1975481646
Cited by
250
References
1
FWCI
9.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Short‐and Long‐Term Reproducibility of QT, QTc, and QT Dispersion Measurement in Healthy Subjects. https://app.cochat.ai/papers/10.1111/j.1540-8159.1994.tb01435.x
The paper
KAUTZNER, J., YI, G., CAMM, A. J., & MALIK, M. (1994). Short‐and Long‐Term Reproducibility of QT, QTc, and QT Dispersion Measurement in Healthy Subjects. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1994.tb01435.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.