Short‐and Long‐Term Reproducibility of QT, QTc, and QT Dispersion Measurement in Healthy Subjects
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
The study investigated interobserver and intrasubject reproducibility of QT interval duration and dispersion measured in standard 12‐lead ECGs recorded at 25 mm/sec. Twenty‐eight healthy volunteers were studied. Each undenvent four ECG recordings, which were performed 1, 7, and 30 days apart. Two independent observers analyzed each ECG record. In each lead with a distinguishable T wave pattern, the RR interval, Q‐peak of T interval, and Q‐end of T interval were measured using a digitizing board with a 0.1‐mm resolution. From each recording the following measures were derived: the maximum, minimum, and mean QT interval; maximum, minimum, and mean heart rate corrected QT interval (QTc); QT and QTc dispersion (the difference between the maximum and minimum QT interval among the 12 leads); and adjusted QT and QTc dispersion (dispersion divided by the square root of the number of leads measured). The interobserver and short‐term (1 day) and long‐term (1 week and 1 month) reproducibility of individual indices was assessed by computing the relative errors and comparing them by a standard sign test. In addition, the distributions of maximum and minimum QTc values among electrocardiographicleads, and the differences between QT‐end and QT‐peak based measurements were investigated. The results showed that: (1) the measurement of the QT interval from standard ECG recordings is feasible and not operator dependent (interobserver relative error <4%); (2) the duration of the QT interval in healthy volunteers is stable and its short‐ and long‐term reproducibility is high (intrasubject relative error < 6%); (3) parameters that characterize dispersion of the QT interval in the 12‐lead ECG are highly nonreproducible, both between subsequent recording (relative error of 25%–35%) and between observers (relative errar 28%–33%), the reproducibility of QT dispersion is significantly lower than that of QT duration (P < 0.01); and (4) the duration of the entire QT interval correlates only weakly with the duration of the Q‐peak of T interval.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
QT dispersion: an indication of arrhythmia risk in patients with long QT intervals.
Day, C. P., McComb, J. M., & Campbell, R. W. (1990) · Heart · doi:10.1136/hrt.63.6.342 · Cited by 1,189
QT interval prolongation as predictor of sudden death in patients with myocardial infarction.
Schwartz, P. J., & Wolf, S. (1978) · Circulation · doi:10.1161/01.cir.57.6.1074 · Cited by 753
QT interval prolongation predicts cardiovascular mortality in an apparently healthy population.
Schouten, E. G., Dekker, J. M., Meppelink, P., Kok, F. J., Vandenbroucke, J. P., & Pool, J. (1991) · Circulation · doi:10.1161/01.cir.84.4.1516 · Cited by 630
The Measurement of the Q-T Interval of the Electrocardiogram
LEPESCHKIN, E., & SURAWICZ, B. (1952) · Circulation · doi:10.1161/01.cir.6.3.378 · Cited by 624
Algra, A., Tijssen, J. G., Roelandt, J. R., Pool, J., & Lubsen, J. (1991) · Circulation · doi:10.1161/01.cir.83.6.1888 · Cited by 592
Hii, J. T., Wyse, D. G., Gillis, A. M., Duff, H. J., Solylo, M. A., & Mitchell, L. B. (1992) · Circulation · doi:10.1161/01.cir.86.5.1376 · Cited by 385
Importance of lead selection in QT interval measurement
Cowan, J. C., Yusoff, K., Moore, M., Amos, P. A., Gold, A. E., Bourke, J. P., Tansuphaswadikul, S., & Campbell, R. W. F. (1988) · The American Journal of Cardiology · doi:10.1016/0002-9149(88)91309-4 · Cited by 337
Long QT: Good, bad or indifferent?
Surawicz, B., & Knoebel, S. B. (1984) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(84)80232-6 · Cited by 232
Reduction in QT dispersion by sotalol following myocardial infarction
DAY, C. P., McCOMB, J. M., MATTHEWS, J., & CAMPBELL, R. W. F. (1991) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a059911 · Cited by 203
Ahnve, S., Gilpin, E. A., Madsen, E. B., Froelicher, V. F., Henning, H., & Ross, J. (1984) · American Heart Journal · doi:10.1016/0002-8703(84)90631-8 · Cited by 120
Long QT syndrome. New electrocardiographic characteristics.
Benhorin, J., Merri, M., Alberti, M., Locati, E., Moss, A. J., Hall, W. J., & Cui, L. (1990) · Circulation · doi:10.1161/01.cir.82.2.521 · Cited by 105
QT interval variability on the body surface
Sylvén, J. C., Horáček, B. M., Spencer, C., Klassen, G. A., & Montague, T. J. (1984) · Journal of Electrocardiology · doi:10.1016/s0022-0736(84)81093-6 · Cited by 97
Measurement of the QT Interval
Campbell, R. W. F., Gardiner, P., Amos, P. A., Chadwick, D., & Jordan, R. S. (1985) · European Heart Journal · doi:10.1093/eurheartj/6.suppl_d.81 · Cited by 78
Prolongation of the QT interval as an indicator of risk of a cardiac event
Ward, D. E. (1988) · European Heart Journal · doi:10.1093/eurheartj/9.suppl_g.139 · Cited by 69
Prognostic value of QT interval prolongation in post myocardial infarction patients
Locati, E. H., & Schwartz, P. J. (1987) · European Heart Journal · doi:10.1093/eurheartj/8.suppl_a.121 · Cited by 35 · cited 1×
“01); and (4) the duration of the entire QT interval correlates only weakly with the duration of the Q-peak of T interval.”
Background
Cited by
Measurement, interpretation and clinical potential of QT dispersion
Malik, M., & Batchvarov, V. N. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00962-1 · Cited by 631
Self-citationQTc-interval abnormalities and psychotropic drug therapy in psychiatric patients
Reilly, J., Ayis, S., Ferrier, I., Jones, S., & Thomas, S. (2000) · The Lancet · doi:10.1016/s0140-6736(00)02035-3 · Cited by 602
Castro Hevia, J., Antzelevitch, C., Tornés Bárzaga, F., Dorantes Sánchez, M., Dorticós Balea, F., Zayas Molina, R., Quiñones Pérez, M. A., & Fayad Rodríguez, Y. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.12.049 · Cited by 528
Perkiömaki, J. S., Koistinen, M. J., Yli-mayry, S., & Huikuri, H. V. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00122-g · Cited by 401
Drug‐Induced Torsades de Pointes and Implications for Drug Development
FENICHEL, R. R., MALIK, M., ANTZELEVITCH, C., SANGUINETTI, M., RODEN, D. M., PRIORI, S. G., RUSKIN, J. N., LIPICKY, R. J., CANTILENA, L. R., & Independent Academic Task Force (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.03534.x · Cited by 346
Self-citation
Metadata
- Authors
- KAUTZNER, J., YI, G., CAMM, A. J., & MALIK, M.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1994-05
- Volume
- 17
- Issue
- 5
- Pages
- 928-937
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W1975481646
- Cited by
- 250
- References
- 17
- FWCI
- 9.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.