Holter, Loop Recorder, and Event Counter Capabilities of Implanted Devices
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The current generation of cardiac pacemakers and implantable cardioverter defibrillators almost all have some capabilites to store data regarding device activity and patient events for future retrieval. This information may provide valuable information regarding device function and whether this is proving valuable in patient management. Examples include “pace‐sense” counters, which can reveal under sensing of patient events, and serial lead impedance measurements, which are able to demonstrate trends not seen on isolated measurements. Holter capabilities become vital in more advanced devices for documenting the utility of, and fine tuning the programming of, features such as antitachycardia pacing, rate‐responsiveness, and mode‐switching. Finally, the ability to store patient events as marker channels and even intrac‐ardiac electrograms adds a diagnostic capability not available through external monitoring. This role has now been advanced by the development of a purely diagnostic implantable loop recorder.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Incremental diagnostic yield of loop electrocardiographic recorders in unexplained syncope
Linzer, M., Pritchett, E. L. C., Pontinen, M., McCarthy, E., & Divine, G. W. (1990) · The American Journal of Cardiology · doi:10.1016/0002-9149(90)90591-n · Cited by 239
The Duration of Holter Monitoring in Patients With Syncope: Is 24 Hours Enough?
Bass, E. B. (1990) · Archives of Internal Medicine · doi:10.1001/archinte.1990.00390170103022 · Cited by 156
Brown, A. P., Dawkins, K. D., & Davies, J. G. (1987) · Heart · doi:10.1136/hrt.58.3.251 · Cited by 96
Utility of Patient-Activated Cardiac Event Recorders in General Clinical Practice
Zimetbaum, P., Kim, K. Y., Ho, K. K. L., Zebede, J., Josephson, M. E., & Goldberger, A. L. (1997) · The American Journal of Cardiology · doi:10.1016/s0002-9149(96)00766-7 · Cited by 77
Cited by
Glotzer, T. V., Hellkamp, A. S., Zimmerman, J., Sweeney, M. O., Yee, R., Marinchak, R., Cook, J., Paraschos, A., Love, J., Radoslovich, G., et al. (2003) · Circulation · doi:10.1161/01.cir.0000057981.70380.45 · Cited by 750
Barold, S. S. (1998) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.1998.tb00044.x · Cited by 8
(2010) · PubMed · Cited by 5
Metadata
- Authors
- WAKTARE, J. E. P., & MALIK, M.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1997-10
- Volume
- 20
- Issue
- 10
- Pages
- 2658-2669
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2002915671
- Cited by
- 40
- References
- 4
- FWCI
- 1.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Holter, Loop Recorder, and Event Counter Capabilities of Implanted Devices. https://app.cochat.ai/papers/10.1111/j.1540-8159.1997.tb06114.x
- The paper
- WAKTARE, J. E. P., & MALIK, M. (1997). Holter, Loop Recorder, and Event Counter Capabilities of Implanted Devices. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1997.tb06114.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.