The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Psychosocial Outcome after ICD Implantation: A Current Perspective
Abstract
Depression and reduced sexual functioning have been identified as problems following ICD placement. We examined these issues, and multiple other quality‐of‐life measures, and their relationship to ICD and ICD discharge. Patients were 64 ± 11 years old, 72% male, and had undergone ICD 20 ± 14 months previously. Fifty‐eight patients responded to a confidential biopsychosocial questionnaire. Positive attitudes toward the procedure increased from 52% before to 76% after implantation. Satisfaction correlated most strongly with less anger (P = 0.002, r = 0.45), less worry about ICD size (P = 0.007, r = 0.38), less sadness (P = 0.01, r = 0.37), and perceived better health (P = 0.01, r = 0.35). Of these ICD patients, 20%–58% reported measures of depression, and sexual frequency was reduced in 45%. Despite successful ICD placement, health concern increased in 62 % of the respondents. Thirty‐nine percent attended support groups; 96% found them very helpful. Mean number of ICD discharges described by responders was 5 ± 11. Fifty percent of our sample reported ≥ 1 shock; equal numbers had 1, 2–5, 6–10, and more than 10 shocks. Sixty‐two percent of men had at least one discharge compared to 13% of women. After controlling for cardiac clinical variables, experiencing ≥ 1 ICD shock was strongly associated with anxiety about family (odds ratio = 7.3), reduced new activities (odds ratio = 6.9), increased sadness (odds ratio = 6.2), and health worry (odds ratio = 5.8). Experiencing ≥ 5 ICD shocks was strongly associated with increased health concern (odds ratio = 13.6), increased sadness (odds ratio = 12.5), increased fatigue (odds ratio = 6.1), current sadness (odds ratio = 5.8), and increased nervousness (odds ratio = 5.3). ICD implantation powerfully affects quality‐of‐life. Postimplantation health concern is paradoxically increased despite improvement in actual health. Negative emotions are associated with defibrillator discharge.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hostility, CHD Incidence, and Total Mortality: A 25-Year Follow-Up Study of 255 Physicians
Barefoot, J. C., Dahlstrom, G. W., & Williams, R. B. (1983) · Psychosomatic Medicine · doi:10.1097/00006842-198303000-00008 · Cited by 866
Sudden Cardiac Death Triggered by an Earthquake
Leor, J., Poole, W. K., & Kloner, R. A. (1996) · New England Journal of Medicine · doi:10.1056/nejm199602153340701 · Cited by 819
Motor vehicle accidents in patients with an implantable cardioverter-defibrillator
Curtis, A. B., Conti, J. B., Tucker, K. J., Kubilis, P. S., Reilly, R. E., & Woodard, D. A. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00133-k · Cited by 77
Cited by
Schron, E. B., Exner, D. V., Yao, Q., Jenkins, L. S., Steinberg, J. S., Cook, J. R., Kutalek, S. P., Friedman, P. L., Bubien, R. S., Page, R. L., et al. (2002) · Circulation · doi:10.1161/hc0502.103330 · Cited by 624
Self-citationQuality of life in the Canadian Implantable Defibrillator Study (CIDS)
Irvine, J., Dorian, P., Baker, B., O'Brien, B. J., Roberts, R., Gent, M., Newman, D., & Connolly, S. J. (2002) · American Heart Journal · doi:10.1067/mhj.2002.124049 · Cited by 368
Examining the psychosocial impact of implantable cardioverter defibrillators: A literature review
Camm, A. J., Sears, S. F., Todaro, J. F., Lewis, T. S., Sotile, W., & Conti, J. B. (1999) · Clinical Cardiology · doi:10.1002/clc.4960220709 · Cited by 292
Implantable Cardioverter–Defibrillators
DiMarco, J. P. (2003) · New England Journal of Medicine · doi:10.1056/nejmra035432 · Cited by 290
Psychopathology in Patients with ICDs over Time: Results of a Prospective Study
KAPA, S., ROTONDI-TREVISAN, D., MARIANO, Z., AVES, T., IRVINE, J., DORIAN, P., & HAYES, D. L. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02599.x · Cited by 112
Metadata
- Authors
- HELLER, S. S., ORMONT, M. A., LIDAGOSTER, L., SCIACCA, R. R., & STEINBERG, J. S.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1998-06
- Volume
- 21
- Issue
- 6
- Pages
- 1207-1215
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W1981919609
- Cited by
- 168
- References
- 3
- FWCI
- 4.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Psychosocial Outcome after ICD Implantation: A Current Perspective. https://app.cochat.ai/papers/10.1111/j.1540-8159.1998.tb00179.x
- The paper
- HELLER, S. S., ORMONT, M. A., LIDAGOSTER, L., SCIACCA, R. R., & STEINBERG, J. S. (1998). Psychosocial Outcome after ICD Implantation: A Current Perspective. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1998.tb00179.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.