The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Intravascular Extraction of Problematic or Infected Permanent Pacemaker Leads: 1994–1996
Abstract
Of the 400,000–500,000 permanent pacemaker leads implanted worldwide each year, around 10% may eventually fail or become infected, becoming potential candidates for removal. Intravascular techniques for removing problematic or infected leads evolved over a 5‐year period (1989–1993). This article analyzes results from January 1994 through April 1996, a period during which techniques were fairly stable. Extraction of 3,540 leads from 2,338 patients was attempted at 226 centers. Indications were: infection (27%), nonfunctional or incompatible leads (25%), Accufix® or Encor® leads (46%), or other causes (2%). Patients were 64 ± 17 years of age (range 5–96); 59% were men, 41% women. Leads were implanted 47 ± 41 months (maximum 26 years), in the atrium (53%), ventricle (46%), or SVC (1%). Extraction was attempted via the implant vein using locking stylets and dilator sheaths, and/or transfemorally using snares, retrieval baskets, and sheaths. Complete removal was achieved for 93% of leads, partial for 5%, and 2% were not removed. Risk of incomplete or failed extraction increased with implant duration (P < 0.0001), less experienced physicians (P < 0.0001), ventricular leads (P < 0.005), noninfected patients (P < 0.0005), and younger patients (P < 0.0001). Major complications were reported for 1.4% of patients (< 1% at centers with > 300 cases), minor for 1.7%. Risk of complications increased with number of leads removed (P < 0.005) and with less experienced physicians (P < 0.005); risk of major complications was higher for women (P < 0.01). Given physician experience, appropriate precautions, and appropriate patient selection, contemporary lead removal techniques allow success with low complication rates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Antibiotic Prophylaxis for Permanent Pacemaker Implantation: A Meta-Analysis
Da Costa, A., Kirkorian, G., Cucherat, M., Delahaye, F., Chevalier, P., Cerisier, A., Isaaz, K., & Touboul, P. (1998) · Circulation · doi:10.1161/01.cir.97.18.1796 · Cited by 362
Five‐Years Experience with Intravascular Lead Extraction
SMITH, H. J., FEARNOT, N. E., BYRD, C. L., WILKOFF, B. L., LOVE, C. J., SELLERS, T. D., & DATABASE, F. T. U. S. L. E. (1994) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1994.tb03792.x · Cited by 278
Self-citationECTOR, H., REYBROUCK, T., HEIDBÜCHEL, H., GEWILLIG, M., & VAN DE WERF, F. (1998) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1998.tb01087.x · Cited by 167
Survey of cardiac pacing and defibrillation in the United States in 1993
Bernstein, A. D., & Parsonnet, V. (1996) · The American Journal of Cardiology · doi:10.1016/s0002-9149(96)90394-x · Cited by 126
Extraction of implanted transvenous pacing leads: A review of a persistent clinical problem
Myers, M. R., Parsonnet, V., & Bernstein, A. D. (1991) · American Heart Journal · doi:10.1016/0002-8703(91)90203-t · Cited by 76
Kawanishi, D. T., SONG, S. L., Furman, S., Parsonnet, V., PIOGER, G., PETITOT, J. C., GODIN, J., & for the BILITCH REGISTRY and STIMAREC (1996) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1996.tb03232.x · Cited by 23
Cited by
Kusumoto, F. M., Schoenfeld, M. H., Wilkoff, B. L., Berul, C. I., Birgersdotter-Green, U. M., Carrillo, R., Cha, Y.-M., Clancy, J., Deharo, J.-C., Ellenbogen, K. A., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.09.001 · Cited by 1,199
Self-citationLead Extraction in the Contemporary Setting: The LExICon Study
Wazni, O., Epstein, L. M., Carrillo, R. G., Love, C., Adler, S. W., Riggio, D. W., Karim, S. S., Bashir, J., Greenspon, A. J., DiMarco, J. P., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.08.070 · Cited by 584
Self-citationBongiorni, M. G., Burri, H., Deharo, J. C., Starck, C., Kennergren, C., Saghy, L., Rao, A., Tascini, C., Lever, N., Kutarski, A., et al. (2018) · EP Europace · doi:10.1093/europace/euy050 · Cited by 401
Self-citationNORTH AMERICAN SOCIETY OF PACING AND ELECTROPHYSIOLOGY LEAD EXTRACTION CONFERENCE FACULTY, LOVE, C. J., WILKOFF, B. L., BYRD, C. L., BELOTT, P. H., BRINKER, J. A., FEARNOT, N. E., FRIEDMAN, R. A., FURMAN, S., GOODE, L. B., et al. (2000) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2000.tb00845.x · Cited by 353
Self-citationGould, P. A. (2006) · JAMA · doi:10.1001/jama.295.16.1907 · Cited by 288
Metadata
- Authors
- BYRD, C. L., WILKOFF, B. L., LOVE, C. J., SELLERS, T. D., TURK, K. T., REEVES, R., YOUNG, R., CREVEY, B., KUTALEK, S. P., FREEDMAN, R., FRIEDMAN, R., TRANTHAM, J., WATTS, M., SCHUTZMAN, J., OREN, J., WILSON, J., GOLD, F., FEARNOT, N. E., VAN ZANDT, H. J., & U.S. EXTRACTION DATABASE, M. I.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1999-09
- Volume
- 22
- Issue
- 9
- Pages
- 1348-1357
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2070115789
- Cited by
- 279
- References
- 6
- FWCI
- 4.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intravascular Extraction of Problematic or Infected Permanent Pacemaker Leads: 1994–1996. https://app.cochat.ai/papers/10.1111/j.1540-8159.1999.tb00628.x
- The paper
- BYRD, C. L., WILKOFF, B. L., LOVE, C. J., SELLERS, T. D., TURK, K. T., REEVES, R., YOUNG, R., CREVEY, B., KUTALEK, S. P., FREEDMAN, R., FRIEDMAN, R., TRANTHAM, J., WATTS, M., SCHUTZMAN, J., OREN, J., WILSON, J., GOLD, F., FEARNOT, N. E., VAN ZANDT, H. J., & U.S. EXTRACTION DATABASE, M. I. (1999). Intravascular Extraction of Problematic or Infected Permanent Pacemaker Leads: 1994–1996. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1999.tb00628.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.