The DOI matches its Crossref record.
Five‐Years Experience with Intravascular Lead Extraction
Abstract
From December 1988 to April 1994, the extraction of 2,195 intravascular pacing leads from 1.299 patients was attempted at 193 centers. Indications were: infection (54%, including 10% septicemia), pacemaker reoperation with removal of nonfunctional or incompatible leads (40%), and other causes (6%). Extraction was attempted via the implant vein using locking stylets and dilator sheaths, via the femoral vein using snares, retrieval baskets, and sheaths, or via both approaches. Leads had been implanted for 0.2 months to 24 years (mean 56 months). At the conclusion of the intravascular procedure, 86.8% of the leads were completely removed, 7.5% were partially removed, and 5.7% were not removed. For physicians performing their first case, 12% of leads were not removed; for physicians who had performed more than 10 cases, only 2% of leads were not removed. Of the 189 leads where extraction attempts had previously failed, 75.1% were completely removed, 14.8% were partially removed, and 10.1% were not removed. Scar tissue increased in severity with implant duration, was a complicating factor, and was the main cause of failure to remove leads. Use of the femoral approach increased with implant duration (5% of leads implanted 12 months or less, 11% of leads 13 months to 3 years, 20% of leads 4–7 years, and 31 % of leads 8–24 years), primarily because of increasingly abundant scarring and prior lead damage. Fatal and near fatal complications occurred in 2.5%. including 8 (0.6%) deaths (3 hemopericardium/tamponade, 1 hemothorax, 3 pulmonary embolus, 1 stroke). With experienced operators, appropriate precautions, and appropriate patient selection, modern techniques allow the successful extraction of up to nearly 98% of intravascular leads with a relatively low incidence of complications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wilkoff, B. L., Byrd, C. L., Love, C. J., Hayes, D. L., Sellers, T. D., Schaerf, R., Parsonnet, V., Epstein, L. M., Sorrentino, R. A., & Reiser, C. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00074-1 · Cited by 438
Self-citationNORTH AMERICAN SOCIETY OF PACING AND ELECTROPHYSIOLOGY LEAD EXTRACTION CONFERENCE FACULTY, LOVE, C. J., WILKOFF, B. L., BYRD, C. L., BELOTT, P. H., BRINKER, J. A., FEARNOT, N. E., FRIEDMAN, R. A., FURMAN, S., GOODE, L. B., et al. (2000) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2000.tb00845.x · Cited by 353
Self-citationIntravascular Extraction of Problematic or Infected Permanent Pacemaker Leads: 1994–1996
BYRD, C. L., WILKOFF, B. L., LOVE, C. J., SELLERS, T. D., TURK, K. T., REEVES, R., YOUNG, R., CREVEY, B., KUTALEK, S. P., FREEDMAN, R., et al. (1999) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1999.tb00628.x · Cited by 279
Self-citationHauser, R. G., Katsiyiannis, W. T., Gornick, C. C., Almquist, A. K., & Kallinen, L. M. (2010) · Europace · doi:10.1093/europace/eup375 · Cited by 264
Guidelines for Managing Pacemaker and Implantable Defibrillator Advisories
Kramer, D. B., & Maisel, W. H. (2011) · Clinical Cardiac Pacing, Defibrillation and Resynchronization Therapy · doi:10.1016/b978-1-4377-1616-0.00034-5 · Cited by 8
Metadata
- Authors
- SMITH, H. J., FEARNOT, N. E., BYRD, C. L., WILKOFF, B. L., LOVE, C. J., SELLERS, T. D., & DATABASE, F. T. U. S. L. E.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1994-11
- Volume
- 17
- Issue
- 11
- Pages
- 2016-2020
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2161052336
- Cited by
- 278
- References
- 0
- FWCI
- 5.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Five‐Years Experience with Intravascular Lead Extraction. https://app.cochat.ai/papers/10.1111/j.1540-8159.1994.tb03792.x
- The paper
- SMITH, H. J., FEARNOT, N. E., BYRD, C. L., WILKOFF, B. L., LOVE, C. J., SELLERS, T. D., & DATABASE, F. T. U. S. L. E. (1994). Five‐Years Experience with Intravascular Lead Extraction. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1994.tb03792.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.