The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Complications of Implantable Cardioverter Defibrillator Therapy in 440 Consecutive Patients
Open accessAbstract
Background: Although more than 150,000 implantable cardioverter defibrillators (ICDs) are implanted yearly worldwide, only few studies systematically examined complications of ICD therapy in large patient cohorts. Methods: We prospectively analyzed ICD‐related complications in 440 consecutive patients who underwent first implantation of an ICD system for primary or secondary prevention of sudden cardiac death within the last 10 years at our institution. All study patients received pectoral nonthoracotomy ICD lead systems with the exception of one patient who had an artificial tricuspid valve. Results: During 46 ± 37 months follow‐up, 136 of 440 patients (31%) experienced at least one complication including implant procedure‐related complications in 43 patients (10%), ICD generator‐related complications in 28 patients (6%), lead‐related complications in 52 patients (12%), and inappropriate shocks in 54 patients (12%). The most serious complications included one perioperative death due to heart failure (0.2%), two ICD system infections necessitating device removal (0.5%) and two perioperative cerebrovascular strokes (0.5%). Conclusions: We conclude that more than one quarter of ICD patients experience complications during a mean follow‐up of almost 4 years, although serious complications such as intraoperative death or ICD system infections are rare in patients with nonthoracotomy ICD systems. Recognition of these complications is the prerequisite for advances in ICD technology and management strategies to avoid their recurrence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moss, A. J., Zareba, W., Hall, W. J., Klein, H., Wilber, D. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Brown, M. W., & Andrews, M. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013474 · Cited by 6,902
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
The Cardiac Insufficiency Bisoprolol Study II (CIBIS-II): a randomised trial
(1999) · The Lancet · doi:10.1016/s0140-6736(98)11181-9 · Cited by 4,929
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
(1997) · New England Journal of Medicine · doi:10.1056/nejm199711273372202 · Cited by 3,232
Effect of carvedilol on survival in severe chronic heart failure
Packer, M., Coats, A. J. S., Fowler, M. B., Katus, H. A., Krum, H., Mohacsi, P., Rouleau, J. L., Tendera, M., Castaigne, A., Roecker, E. B., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200105313442201 · Cited by 3,093
Prevention of Implantable-Defibrillator Shocks by Treatment with Sotalol
Pacifico, A., Hohnloser, S. H., Williams, J. H., Tao, B., Saksena, S., Henry, P. D., & Prystowsky, E. N. (1999) · New England Journal of Medicine · doi:10.1056/nejm199906173402402 · Cited by 422
Implantable Cardioverter–Defibrillators
DiMarco, J. P. (2003) · New England Journal of Medicine · doi:10.1056/nejmra035432 · Cited by 290
Implantable transvenous cardioverter-defibrillators.
Bardy, G. H., Hofer, B., Johnson, G., Kudenchuk, P. J., Poole, J. E., Dolack, G. L., Gleva, M., Mitchell, R., & Kelso, D. (1993) · Circulation · doi:10.1161/01.cir.87.4.1152 · Cited by 273
Cited by
Tong, S. Y. C., Davis, J. S., Eichenberger, E., Holland, T. L., & Fowler, V. G. (2015) · Clinical Microbiology Reviews · doi:10.1128/cmr.00134-14 · Cited by 5,192
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2013) · Circulation · doi:10.1161/cir.0b013e318276ce9b · Cited by 1,489
Inappropriate Implantable Cardioverter-Defibrillator Shocks in MADIT II
Daubert, J. P., Zareba, W., Cannom, D. S., McNitt, S., Rosero, S. Z., Wang, P., Schuger, C., Steinberg, J. S., Higgins, S. L., Wilber, D. J., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.09.073 · Cited by 813
An Entirely Subcutaneous Implantable Cardioverter–Defibrillator
Bardy, G. H., Smith, W. M., Hood, M. A., Crozier, I. G., Melton, I. C., Jordaens, L., Theuns, D., Park, R. E., Wright, D. J., Connelly, D. T., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa0909545 · Cited by 780
Metadata
- Authors
- ALTER, P., WALDHANS, S., PLACHTA, E., MOOSDORF, R., & GRIMM, W.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 2005-09
- Volume
- 28
- Issue
- 9
- Pages
- 926-932
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2106843471
- Cited by
- 274
- References
- 23
- FWCI
- 13.15
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Complications of Implantable Cardioverter Defibrillator Therapy in 440 Consecutive Patients. https://app.cochat.ai/papers/10.1111/j.1540-8159.2005.00195.x
- The paper
- ALTER, P., WALDHANS, S., PLACHTA, E., MOOSDORF, R., & GRIMM, W. (2005). Complications of Implantable Cardioverter Defibrillator Therapy in 440 Consecutive Patients. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2005.00195.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.