CoChat

Long‐Term Outcomes of a Telephone Intervention After an ICD

DOUGHERTY, CYNTHIA M., THOMPSON, ELAINE ADAMS, LEWIS, FRANCES MARCUS · 2005 · Pacing and Clinical Electrophysiology
Cited by 104

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: The purpose of this study was to determine the long‐term benefits of participating in a structured, 8‐week educational telephone intervention delivered by expert cardiovascular nurses post‐ICD. The intervention was aimed to (1) increase physical functioning, (2) increase psychological adjustment, (3) improve self‐efficacy in managing the challenges of ICD recovery, and (4) lower levels of health care utilization over usual care in the first 12 months post‐ICD. This article reports on the 6‐ and 12‐month outcomes of the nursing intervention trial. Methods and Results: A two‐group (N = 168) randomized control group design was used to evaluate intervention efficacy with persons receiving an ICD for the secondary prevention of sudden cardiac arrest. Measures were obtained at baseline, 6 and 12 months post hospitalization. Outcomes included (1) physical functioning (Patient Concerns Assessment [PCA], Short Form Health Survey [SF‐12], ICD shocks), (2) psychological adjustment (State‐Trait Anxiety Inventory [STAI], Centers for Epidemiologic Studies–Depression [CES‐D], fear of dying), (3) self‐efficacy (Sudden Cardiac Arrest–Self‐Efficacy [SCA‐SE], Sudden Cardiac Arrest–Behavior [SCA‐B], Sudden Cardiac Arrest–Knowledge [SCA‐K]), and (4) health care utilization (emergency room [ER] visits, outpatient visits, hospitalizations). Using repeated measures ANOVA, the 6‐ and 12‐month benefits of the intervention over usual care were in reductions in physical concerns (P = 0.006), anxiety (P = 0.04), and fear of dying (P = 0.01), with enhanced self‐confidence (P = 0.04) and knowledge (P = 0.001) to manage ICD recovery. There were no statistically significant differences between the groups on total outpatient visits, hospitalizations, or ER visits over 12 months. Conclusion: A structured 8‐week post‐hospital telephone nursing intervention after an ICD had sustained 12‐month improvements on patient concerns, anxiety, fear of dying, self‐efficacy, and knowledge. Results may not apply to individuals with congestive heart failure who receive an ICD for primary prevention of sudden cardiac arrest.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.2005.09500.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 104

Metadata

Authors
DOUGHERTY, C. M., THOMPSON, E. A., & LEWIS, F. M.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2005-11
Volume
28
Issue
11
Pages
1157-1167
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W1995952765
Cited by
104
References
2
FWCI
4.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Long‐Term Outcomes of a Telephone Intervention After an ICD. https://app.cochat.ai/papers/10.1111/j.1540-8159.2005.09500.x
The paper
DOUGHERTY, C. M., THOMPSON, E. A., & LEWIS, F. M. (2005). Long‐Term Outcomes of a Telephone Intervention After an ICD. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2005.09500.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.