Background: Implantable cardioverter defibrillators (ICDs) are life‐saving devices in treatment of life‐threatening arrhythmia. We evaluate the emotional status of Turkish patients with ICD and try to explain factors that affect emotional status of the patients. Methods: Ninety‐one patients with previously implanted ICD were included in the study. Follow‐up periods, presence of ICD shock, shock frequency, time of the recent shock, age, and gender were noted. Depression and anxiety scores were evaluated according to Hospital Anxiety and Depression (HAD) chart. Results: Mean anxiety and depression scores were found as 9.1 ± 5.3 and 7.2 ± 5.1, respectively. According to HAD charts, 42 patients (46%) had anxiety and 37 patients (41%) had depression. Depression scores indicated significant difference between subgroups divided on the basis of follow‐up periods (P = 0.026) and on the basis of time of recent shock (P = 0.028). There was significant difference in anxiety scores (P = 0.016) between patients with ICD shocks and patients with no shocks. When the patients were divided into subgroups according to shock frequency, both depression (P = 0.024) and anxiety (P = 0.016) scores presented significant difference. In female patients, depression and anxiety scores were found significantly higher compared to male patients (P = 0.046 and P = 0.016, respectively). In multivariate analysis, gender and shock frequency were found as predictors for anxiety scores (P = 0.019 and P = 0.044, respectively). However same analysis revealed no predictive factor for depression score. Conclusion: Our study indicates presence of depression and anxiety in nearly half of the patients with ICD. Consultation with psychiatry should be a part of the treatment for patients with ICD, especially for those who constitute high‐risk groups.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The validity of the Hospital Anxiety and Depression Scale
Bjelland, I., Dahl, A. A., Haug, T. T., & Neckelmann, D. (2002) · Journal of Psychosomatic Research · doi:10.1016/s0022-3999(01)00296-3 · Cited by 9,779
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
Herrmann, C. (1997) · Journal of Psychosomatic Research · doi:10.1016/s0022-3999(96)00216-4 · Cited by 2,885
DSM-III-R Generalized Anxiety Disorder in the National Comorbidity Survey
Wittchen, H.-U. (1994) · Archives of General Psychiatry · doi:10.1001/archpsyc.1994.03950050015002 · Cited by 967
La Rovere, M. T., Pinna, G. D., Maestri, R., Mortara, A., Capomolla, S., Febo, O., Ferrari, R., Franchini, M., Gnemmi, M., Opasich, C., et al. (2003) · Circulation · doi:10.1161/01.cir.0000047275.25795.17 · Cited by 917
Schron, E. B., Exner, D. V., Yao, Q., Jenkins, L. S., Steinberg, J. S., Cook, J. R., Kutalek, S. P., Friedman, P. L., Bubien, R. S., Page, R. L., et al. (2002) · Circulation · doi:10.1161/hc0502.103330 · Cited by 624
Emotional and physical precipitants of ventricular arrhythmia
Lampert, R., Joska, T., Burg, M. M., Batsford, W. P., McPherson, C. A., & Jain, D. (2002) · Circulation · doi:10.1161/01.cir.0000031733.51374.c1 · Cited by 347
Cited by
Prophylactic Catheter Ablation for the Prevention of Defibrillator Therapy
Reddy, V. Y., Reynolds, M. R., Neuzil, P., Richardson, A. W., Taborsky, M., Jongnarangsin, K., Kralovec, S., Sediva, L., Ruskin, J. N., & Josephson, M. E. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa065457 · Cited by 959
Screening and Management of Depression in Patients With Cardiovascular Disease
Jha, M. K., Qamar, A., Vaduganathan, M., Charney, D. S., & Murrough, J. W. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.01.041 · Cited by 365
Magyar-Russell, G., Thombs, B. D., Cai, J. X., Baveja, T., Kuhl, E. A., Singh, P. P., Montenegro Braga Barroso, M., Arthurs, E., Roseman, M., Amin, N., et al. (2011) · Journal of Psychosomatic Research · doi:10.1016/j.jpsychores.2011.02.014 · Cited by 267
Long-Term Follow-Up of Idiopathic Ventricular Fibrillation Ablation
Knecht, S., Sacher, F., Wright, M., Hocini, M., Nogami, A., Arentz, T., Petit, B., Franck, R., De Chillou, C., Lamaison, D., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.03.065 · Cited by 265
Dunbar, S. B., Dougherty, C. M., Sears, S. F., Carroll, D. L., Goldstein, N. E., Mark, D. B., McDaniel, G., Pressler, S. J., Schron, E., Wang, P., et al. (2012) · Circulation · doi:10.1161/cir.0b013e31825d59fd · Cited by 221
Metadata
- Authors
- BILGE, A. K., OZBEN, B., DEMIRCAN, S., CINAR, M., YILMAZ, E., & ADALET, K.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 2006-06
- Volume
- 29
- Issue
- 6
- Pages
- 619-626
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2078669191
- Cited by
- 179
- References
- 7
- FWCI
- 7.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Depression and Anxiety Status of Patients with Implantable Cardioverter Defibrillator and Precipitating Factors. https://app.cochat.ai/papers/10.1111/j.1540-8159.2006.00409.x
- The paper
- BILGE, A. K., OZBEN, B., DEMIRCAN, S., CINAR, M., YILMAZ, E., & ADALET, K. (2006). Depression and Anxiety Status of Patients with Implantable Cardioverter Defibrillator and Precipitating Factors. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2006.00409.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.