Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 179

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Depression and Anxiety Status of Patients with Implantable Cardioverter Defibrillator and Precipitating Factors

BILGE, AHMET KAYA, OZBEN, BESTE, DEMIRCAN, SABRI, CINAR, MUTLU, YILMAZ, ERCUMENT, ADALET, KAMIL · 2006 · Pacing and Clinical Electrophysiology

Abstract

Background: Implantable cardioverter defibrillators (ICDs) are life‐saving devices in treatment of life‐threatening arrhythmia. We evaluate the emotional status of Turkish patients with ICD and try to explain factors that affect emotional status of the patients. Methods: Ninety‐one patients with previously implanted ICD were included in the study. Follow‐up periods, presence of ICD shock, shock frequency, time of the recent shock, age, and gender were noted. Depression and anxiety scores were evaluated according to Hospital Anxiety and Depression (HAD) chart. Results: Mean anxiety and depression scores were found as 9.1 ± 5.3 and 7.2 ± 5.1, respectively. According to HAD charts, 42 patients (46%) had anxiety and 37 patients (41%) had depression. Depression scores indicated significant difference between subgroups divided on the basis of follow‐up periods (P = 0.026) and on the basis of time of recent shock (P = 0.028). There was significant difference in anxiety scores (P = 0.016) between patients with ICD shocks and patients with no shocks. When the patients were divided into subgroups according to shock frequency, both depression (P = 0.024) and anxiety (P = 0.016) scores presented significant difference. In female patients, depression and anxiety scores were found significantly higher compared to male patients (P = 0.046 and P = 0.016, respectively). In multivariate analysis, gender and shock frequency were found as predictors for anxiety scores (P = 0.019 and P = 0.044, respectively). However same analysis revealed no predictive factor for depression score. Conclusion: Our study indicates presence of depression and anxiety in nearly half of the patients with ICD. Consultation with psychiatry should be a part of the treatment for patients with ICD, especially for those who constitute high‐risk groups.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.2006.00409.x

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 179

Metadata

Authors
BILGE, A. K., OZBEN, B., DEMIRCAN, S., CINAR, M., YILMAZ, E., & ADALET, K.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2006-06
Volume
29
Issue
6
Pages
619-626
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2078669191
Cited by
179
References
7
FWCI
7.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Depression and Anxiety Status of Patients with Implantable Cardioverter Defibrillator and Precipitating Factors. https://app.cochat.ai/papers/10.1111/j.1540-8159.2006.00409.x
The paper
BILGE, A. K., OZBEN, B., DEMIRCAN, S., CINAR, M., YILMAZ, E., & ADALET, K. (2006). Depression and Anxiety Status of Patients with Implantable Cardioverter Defibrillator and Precipitating Factors. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2006.00409.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.