The World Survey of Cardiac Pacingand Cardioverter‐Defibrillators: Calendar Year 2005 An International Cardiac Pacing andElectrophysiology Society (ICPES) project
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Background: A worldwide cardiac pacing and implantable cardioverter‐defibrillator (ICD) survey was undertaken for calendar year 2005 and compared to a similar survey conducted in 2001. Results: There were contributions from 43 countries: 16 from Europe, 13 from the Asia Pacific region, four from the Middle East and Africa, and 10 from the Americas. The United States had the largest number of cardiac pacemaker implants (223,425). Virtually all countries showed increases in implant numbers over the 4 years. High‐degree atrioventricular block and sick sinus syndrome remain the major indications for implantation of a cardiac pacemaker, although indications data were not available for large implanting regions such as Europe, Australia, and the United States. There remains a high percentage of VVI(R) pacing in the developing countries, although compared to the 2001 survey, virtually all countries had increased the percentage of DDDR implants, together with a fall in single‐lead VDD implants. Pacing leads were predominantly transvenous, bipolar, and passive fixation. There was, however, an increased use of active fixation leads in both the atrium and ventricle. All countries surveyed showed a significant rise in the use of ICDs with the largest implanter being the United States (119,121) with 401 new implants per million population. Conclusions: Although the numbers of participating countries have fallen, there still remains a group of loyal enthusiastic survey coordinators. Recruitment of new coordinators will hopefully continue in order to obtain a fully global experience of cardiac pacing and ICD usage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The World Survey of Cardiac Pacing and Cardioverter Defibrillators: Calendar Year 2001
Mond, H. G., IRWIN, M. E., Morillo, C. A., & Ector, H. (2004) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2004.00565.x · Cited by 134
Self-citationCARDIAC PACING AND ELECTROPHYSIOLOGY
Hauser, R. G., & KULBERTUS, H. E. (1986) · Clinical Progress in Electrophysiology and Pacing · doi:10.1111/j.1540-8167.1986.tb01742.x · Cited by 111
Survey of Cardiac Pacing and Implanted Defibrillator Practice Patterns in the United States in 1997
BERNSTEIN, A. D., & PARSONNET, V. (2001) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2001.00842.x · Cited by 93 · cited 4×
“Europe Belgium 99 1 89 11 66 96 34 (49) 4 (4) Croatia 99 1 97 3 77 87 23 (11) 13 (1) Czech Rep 100 <1 99 1 48 80 52 20 (14) Denmark 100 <1 88 12 0 43 100 (61) 57 (9) France 100 <1 89 11 14 72 86 (81) 28 (9) Greece Italy 92 8 86 14 Latvia 100 0 95 5 0 5 100 (21) 95 (21) Lithuania Netherlands 100 <1 98 2 48 77 51 23 (11…”
InfluentialEctor, H., Rickards, A. F., Kappenberger, L., Linde, C. M., Vardas, P. E., Oto, A., Santini, M., Sutton, R., & THE WORKING GROUP ON CARDIAC PACING (2001) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2001.00863.x · Cited by 70
Self-citationMond, H. G. (2001) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2001.00856.x · Cited by 37
Self-citationProclemer, A., Ghidina, M., Cicuttini, G., Gregori, D., & FIORETTI, P. M. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00487.x · Cited by 26
Self-citationA Comparison of ICD Implantations in the United States Versus Italy
GREENBERG, S. M., Epstein, A. E., Deering, T. F., Goldman, D. S., Ghidina, M., NEASON, C., & Proclemer, A. (2007) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2007.00625.x · Cited by 24 · cited 2×
“Asia Pacific Australia 24 (29) <1 1 72 (69) 2 (1) Bangladesh 86 0 0 14 0 Brunei 10 (35) 0 0 90 (65) 0 China 49 (65) 51 (35) Hong Kong 31 (40) <1 1 62 (53) 4 (3) India 84 (69) 1 7 10 (20) Japan 29 (35) 3 (3) 18 (13) 51 (49) 3 (<1) Nepal 100 0 0 0 0 New Zealand 41 (41) 6 (2) <1 51 (51) 2 (2) Singapore 51 (40) <1 6 (16)…”
Self-citation
Cited by
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab364 · Cited by 2,019
MOND, H. G., & PROCLEMER, A. (2011) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2011.03150.x · Cited by 984
Self-citation2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2022) · EP Europace · doi:10.1093/europace/euab232 · Cited by 914
Kirkfeldt, R. E., Johansen, J. B., Nohr, E. A., Jorgensen, O. D., & Nielsen, J. C. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht511 · Cited by 871
Greenspon, A. J., Patel, J. D., Lau, E., Ochoa, J. A., Frisch, D. R., Ho, R. T., Pavri, B. B., & Kurtz, S. M. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.04.033 · Cited by 780
Metadata
- Authors
- MOND, H. G., IRWIN, M., ECTOR, H., & PROCLEMER, A.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 2008-08-28
- Volume
- 31
- Issue
- 9
- Pages
- 1202-1212
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W1990911756
- Cited by
- 165
- References
- 7
- FWCI
- 10.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.