Alert Tones Are Frequently Inaudible among Patients with Implantable Cardioverter‐Defibrillators
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: Current management guidelines for patients with Medtronic Sprint Fidelis ICD leads (Medtronic Inc., Minneapolis, MN, USA) include prominent use of Patient Alert™, a feature in which the ICD generator emits audible beeps at two programmable frequencies. Because hearing loss is highly prevalent beyond the sixth decade of life, the utility of this feature is unclear. Therefore, we conducted a survey of patients’ ability to hear the Medtronic Patient Alert™. Methods: During visits to an outpatient device clinic, patients with Medtronic ICDs were evaluated for their ability to hear ICD tones. Results: The patient group consisted of 102 patients. Patients older than 70 years comprised 68% of the sample, with 16% between 60 and 70, and 17% younger than 60 years. Of the 102 patients, 59% (56% of males and 70% of females) were able to hear at least one tone. Ability to hear ICD tones decreased with advancing age. Among patients over 60 and 70 years, 52% and 43%, respectively (P < 0.001 vs. patients below 60 and 70 years), could hear at least one tone. Conclusions: The Patient Alert™ feature is not useful among a large proportion of ICD patients. Patients with Sprint Fidelis leads should be evaluated for their ability to hear audible ICD tones. For patients who cannot hear the Patient Alert™ feature, a wireless remote monitoring and/or daily application of a magnet by a caregiver should be considered. Device manufacturers should include nonauditory alert technologies such as wireless remote monitoring and vibratory stimulation in future devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Agrawal, Y. (2008) · Archives of Internal Medicine · doi:10.1001/archinte.168.14.1522 · Cited by 977
Cited by
Landolina, M., Perego, G. B., Lunati, M., Curnis, A., Guenzati, G., Vicentini, A., Parati, G., Borghi, G., Zanaboni, P., Valsecchi, S., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.088971 · Cited by 344
Swerdlow, C. D., Gunderson, B. D., Ousdigian, K. T., Abeyratne, A., Sachanandani, H., & Ellenbogen, K. A. (2010) · Circulation · doi:10.1161/circulationaha.110.962407 · Cited by 99
Kallinen, L. M., Hauser, R. G., Tang, C., Melby, D. P., Almquist, A. K., Katsiyiannis, W. T., & Gornick, C. C. (2010) · Heart Rhythm · doi:10.1016/j.hrthm.2010.05.015 · Cited by 62
Dubner, S., Auricchio, A., Steinberg, J. S., Vardas, P., Stone, P., Brugada, J., Piotrowicz, R., Hayes, D. L., Kirchhof, P., Breithardt, G., et al. (2012) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2011.00484.x · Cited by 47
Guidelines for Managing Pacemaker and Implantable Defibrillator Advisories
Kramer, D. B., & Maisel, W. H. (2011) · Clinical Cardiac Pacing, Defibrillation and Resynchronization Therapy · doi:10.1016/b978-1-4377-1616-0.00034-5 · Cited by 8
Metadata
- Authors
- SIMONS, E. C., FEIGENBLUM, D. Y., NEMIROVSKY, D., & SIMONS, G. R.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 2009-09-25
- Volume
- 32
- Issue
- 10
- Pages
- 1272-1275
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2088912210
- Cited by
- 30
- References
- 1
- FWCI
- 3.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.