DDD versus VVIR Pacing in Patients, Ages 70 and Over, with Complete Heart Block: DDD VERSUS VVIR IN ELDERLY PATIENTS
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Dual-chamber pacing is believed to have an advantage over single-chamber ventricular pacing. The aim of the study was to determine whether elderly patients with implanted pacemaker for complete atrioventricular block gain significant benefit from dual-chamber (DDD) compared with single-chamber ventricular demand (VVIR). METHODS: The study was designed as a double-blind randomized two-period crossover study-each pacing mode was maintained for 3 months. Thirty patients (eight men, mean age 76.5 +/- 4.3 years) with implanted PM were submitted to a standard protocol, which included an interview, functional class assessment, quality of life (QoL) questionnaires, 6-minute walk test, and transthoracic echocardiographic examinations. QoL was measured by the SF-36. All these parameters were obtained on DDD mode pacing and VVIR mode pacing. Paired data were compared. RESULTS: QoL was significantly different between the two groups and showed the best values in DDD. Overall, no patient preferred VVIR mode, 18 preferred DDD mode, and 12 expressed no preference. No differences in mean walking distances were observed between patients with single-chamber and dual-chamber pacing. VVI pacing elicited marked decrease in left ventricle ejection fraction and significant enlargement of the left atrium. DDD pacing resulted in significant increase of the peak systolic velocities in lateral mitral annulus and septal mitral annulus. Early diastolic velocities on both sides of mitral annulus did not change. CONCLUSION: In active elderly patients with complete heart block, DDD pacing is associated with improved quality of life and systolic ventricular function compared with VVI pacing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Connolly, S. J., Kerr, C. R., Gent, M., Roberts, R. S., Yusuf, S., Gillis, A. M., Sami, M. H., Talajic, M., Tang, A. S. L., Klein, G. J., et al. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005113421902 · Cited by 775
Research works printed but not linked: 27
- Shmidt, 2003, Pacemaker therapy in very elderly patients: Long term survival and prognostic parameters, Am Heart J, 146, 908, 10.1016/S0002-8703(03)00453-8 · DOI
- Cheitlin, 2001, Database Conference January 27-30, 2000, Washington DC: Do existing databases answer clinical questions about geriatric cardiovascular disease and stroke, Am J Geriatr Cardiol, 10, 207, 10.1111/j.1076-7460.2003.00696.x · DOI
- De Belder, 1992, Cost implications of the British Pacing and Electrophysiology Group's recommendations for pacing, BMJ, 305, 861, 10.1136/bmj.305.6858.861 · DOI
- Stewart, 1984, Doppler ultrasound measurement of cardiac output in patients with physiologic pacemakers. Effects of left ventricular function and retrograde ventriculoatrial conduction, Am J Cardiol, 54, 308, 10.1016/0002-9149(84)90188-7 · DOI
- Lamas, 1995, Permanent pacemaker selection and subsequent survival in elderly Medicare pacemaker recipients, Circulation, 91, 1063, 10.1161/01.CIR.91.4.1063 · DOI · Paper page
- Lamas, 1998, Quality of life and clinical outcomes in elderly patients treated with ventricular pacing as compared with dual-chamber pacing. Pacemaker Selection in the Elderly Investigators, N Engl J Med, 338, 1097, 10.1056/NEJM199804163381602 · DOI · Paper page
- Toff, 2005, Single chamber versus dual chamber pacing for high Grade atrioventricular block, N Engl J Med, 353, 145, 10.1056/NEJMoa042283 · DOI · Paper page
- Naegeli, 2007, Single-chamber ventricular pacing increases markers of left ventricular dysfunction compared with dual-chamber pacing, Europace, 9, 194, 10.1093/europace/eul186 · DOI
- Rediker, 1988, Clinical and hemodynamic comparison of VVI versus DDD pacing in patients with DDD pacemakers, Am J Cardiol, 81, 323, 10.1016/0002-9149(88)90938-1 · DOI
- Heldman, 1990, True incidence of pacemaker syndrome, Pacing Clin Electrophysiol, 13, 1742, 10.1111/j.1540-8159.1990.tb06883.x · DOI
- Ware, 1992, The MOS 36-item short-form health survey (SF-36), I: Conceptual framework and item selection, Med Care, 30, 473, 10.1097/00005650-199206000-00002 · DOI · Paper page
- Ware, 1993, SF-36 Health Survey: Manual and Interpretation Guide
- Jordaens, 1988, Physiologic pacing in the elderly. Effects on exercise capacity and exercice induced arrhythmias, Jpn Heart J, 29, 35, 10.1536/ihj.29.35 · DOI
- Hargreaves, 1995, Comparison of dual chamber and ventricular rate responsive pacing in patients over 75 with complete heart block, Br Heart J, 74, 397, 10.1136/hrt.74.4.397 · DOI
- Channon, 1994, DDD vs VVI pacing in patients aged over 75 years with complete heart block: A double-blind crossover comparison, Quart J Med, 87, 245
- Kritensson, 1985, The haemodynamic importance of atrioventricular synchrony and rate increase at rest and during exercise, Eur Heart J, 6, 773, 10.1093/oxfordjournals.eurheartj.a061940 · DOI
- Faerestrand, 1985, A time-related study of the hemodynamic benefit of atrioventricular synchronous pacing evaluated by Doppler echocardiography, Pacing Clin Electrophysiol, 8, 838, 10.1111/j.1540-8159.1985.tb05903.x · DOI
- Buckingham, 1992, Pacemaker hemodynamics: Clinical implications, Prog Cardiovasc Dis, 34, 347, 10.1016/0033-0620(92)90039-3 · doi:10.1016/0033-0620(92)90039-3
- Fananapazir, 1985, Reliability of the evoked response in determining the paced ventricular rate and performance of the QT or rate responsive (TX) pacemaker, Pacing Clin Electrophysiol, 8, 701, 10.1111/j.1540-8159.1985.tb05883.x · doi:10.1111/j.1540-8159.1985.tb05883.x
- Oldroyd, 1991, Double blind crossover comparison of the effects of dual chamber pacing (DDD) and ventricular rate-adaptive (VVIR) pacing on neuroendocrine variables, exercise performance, and symptoms in complete heart block, Br Heart J, 65, 188, 10.1136/hrt.65.4.188 · DOI
- Frielingsdorf, 1995, Physical work capacity with rate responsive ventricular pacing (VVIR) versus dual chamber pacing (DDD) in patients with normal and diminished left ventricular function, Inter J Cardiol, 49, 239, 10.1016/0167-5273(95)02308-J · DOI
- Kuo, 1987, Quantification of atrial contribution to left ventricular filling by pulsed Doppler echocardiography and the effect of age in normal and diseased hearts, Am J Cardiol, 56, 1174, 10.1016/0002-9149(87)90870-8 · DOI · Paper page
- Miller, 1986, Left ventricular filling and its association with age, Am J Cardiol, 58, 531, 10.1016/0002-9149(86)90028-7 · DOI · Paper page
- Höijer, 2002, Improved cardiac function and quality of life following upgrade to dual chamber pacing after long-term ventricular stimulation, Eur Heart J, 23, 490, 10.1053/euhj.2001.2817 · DOI · Paper page
- Levin, 1998, Natriuretic peptides, N Engl J Med, 339, 321, 10.1056/NEJM199807303390507 · DOI · Paper page
- Lamas, 2002, Mode selection trial in sinus node dysfunction, N Eng J Med, 346, 1854, 10.1056/NEJMoa013040 · DOI · Paper page
- Jahangir, 2003, Pacing in elderly patients, Am Heart J, 146, 750, 10.1016/S0002-8703(03)00454-X · DOI
Cited by
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.044 · Cited by 1,008
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000628 · Cited by 603
Chinitz, L., Ritter, P., Khelae, S. K., Iacopino, S., Garweg, C., Grazia-Bongiorni, M., Neuzil, P., Johansen, J. B., Mont, L., Gonzalez, E., et al. (2018) · Heart Rhythm · doi:10.1016/j.hrthm.2018.05.004 · Cited by 170
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2018.10.037 · Cited by 131
Metadata
- Authors
- OUALI, S., NEFFETI, E., GHOUL, K., HAMMAS, S., KACEM, S., GRIBAA, R., REMEDI, F., & BOUGHZELA, E.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 2009-12-10
- Volume
- 33
- Issue
- 5
- Pages
- 583-589
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W1601080687
- Cited by
- 35
- References
- 1
- FWCI
- 1.78
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- doi.wiley.com/10.1002/tdm_license_1.1 (tdm, 2091 d)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.