CoChat

Permanent Pacemaker Selection and Subsequent Survival in Elderly Medicare Pacemaker Recipients

Lamas, Gervasio A., Pashos, Chris L., Normand, Sharon-Lise T., McNeil, Barbara · 1995 · Circulation
Cited by 148

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background Dual-chamber pacemakers have been in use for more than 15 years. Although they may confer a physiological advantage over single-chamber ventricular pacemakers, they are more expensive and have a generally shorter service life than single-chamber devices. We carried out the present study to identify patient subgroups who were preferentially receiving greater or lesser proportions of dual-chamber devices and to determine whether the selection of different types of pacemakers was associated with differences in mortality. Methods and Results We analyzed a 20% random national sample of all Medicare beneficiaries aged 65 years or older who underwent initial placement of a permanent pacemaker and were discharged in 1988, 1989, or 1990 (n=36 312). The minimum follow-up for vital status was 1 year. The relation of pacemaker type to patient and provider characteristics was determined using logistic regression analysis. The relation between pacemaker type and mortality was determined using the Cox proportional hazards method. The proportion of dual-chamber systems that were received increased from 27.2% in 1988 to 37.0% in 1990 ( P <.001). Dual-chamber pacemaker recipients were younger ( P <.001) than ventricular pacemaker recipients. Other independent correlates of dual-chamber pacemaker selection included male sex (odds ratio and 95% confidence intervals, 1.18 and 1.12 to 1.24, respectively), atrioventricular block (1.59 and 1.51 to 1.67), congestive heart failure (1.14 and 1.08 to 1.20), atrial fibrillation (0.36 and 0.34 to 0.39), and the presence of a major noncardiac diagnosis (0.86 and 0.83 to 0.89). Nonmedical predictors of dual-chamber pacemaker selection included Medicaid eligibility (0.78 and 0.71 to 0.86), implantation in the western United States (1.19 and 1.10 to 1.29), implantation by a rural provider (0.70 and 0.65 to 0.76), hospitalization in a 500-bed-or-larger hospital (1.20 and 1.13 to 1.28), hospitalization in a private hospital (1.19 and 1.10 to 1.28), or hospitalization in a hospital with a catheterization laboratory (1.47 and 1.38 to 1.56). Dual-chamber pacemaker selection was an independent predictor of survival at 1 year (0.82 and 0.77 to 0.87) and at 2 years (0.82 and 0.77 to 0.87) after controlling for potentially confounding patient-level and hospital-level characteristics. Conclusions The present study describes important variations in the clinical practice of cardiac pacing, many of which are not based on clinical characteristics. Furthermore, the selection of a dual-chamber pacemaker is associated with increased survival. These results underscore the need for prospective, outcome-based clinical trials of pacemaker mode selection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.91.4.1063

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 148

Metadata

Authors
Lamas, G. A., Pashos, C. L., Normand, S.-L. T., & McNeil, B.
Venue
Circulation
Published
1995-02-15
Volume
91
Issue
4
Pages
1063-1069
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1967564762
Cited by
148
References
1
FWCI
7.97
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Permanent Pacemaker Selection and Subsequent Survival in Elderly Medicare Pacemaker Recipients. https://app.cochat.ai/papers/10.1161/01.cir.91.4.1063
The paper
Lamas, G. A., Pashos, C. L., Normand, S.-L. T., & McNeil, B. (1995). Permanent Pacemaker Selection and Subsequent Survival in Elderly Medicare Pacemaker Recipients. Circulation. https://doi.org/10.1161/01.cir.91.4.1063

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.