CoChat

Trends of Temporary Pacemaker Implant and Underlying Disease Substrate

JOU, YU‐LAN, HSU, HONG‐PIN, TUAN, TA‐CHUAN, WANG, KANG‐LING, LIN, YENN‐JIANG, LO, LI‐WEI, HU, YU‐FENG, KONG, CHI‐WOON, CHANG, SHIH‐LIN, CHEN, SHIH‐ANN · 2010 · Pacing and Clinical Electrophysiology
Cited by 15

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background: To evaluate contemporary trends of clinical characteristics, etiologies, and underlying diseases, and their relationship between different bradyarrhythmias in patients undergoing temporary pacemakers (TPMs). Methods: This study included 509 patients (77 ± 11 year, 74% males) with symptomatic bradyarrhythmias requiring TPMs between 2002 and 2008. Demographics, electrocardiographic indications, etiologies, underlying diseases, and the outcome of permanent pacemaker (PPM) implants within 30 days were analyzed. Results: Atrioventricular conduction dysfunction (AVCD) (64.0%) dominated in all bradyarrhythmias, with idiopathic degeneration (61%) as its major etiology. Antiarrhythmic drug (38%) was the leading cause in sinoatrial node dysfunction (SAND). There was an increasing trend in AVCD, while a decreasing trend in SAND. Regarding etiologies for TPM, an increasing trend was found in idiopathic degeneration, whereas a decreasing trend in acute coronary syndrome (ACS). Idiopathic degeneration had an odds ratio (OR) of 1.9 for AVCD (P = 0.001), whereas electrolyte/acid‐base disturbances (OR = 3.7, P = 0.001), β‐blockers (OR = 2.4, P = 0.002), and chronic renal disease (OR = 1.9, P = 0.01) were associated with SAND. Patients with intrinsic etiologies for TPM had a high incidence of PPM implantation within 30 days than those with extrinsic causes (67.5% vs 3.8%, P < 0.0001) Conclusion: Increasing trends in patients requiring TPMs were observed in the elderly patients and those with AVCD and idiopathic degeneration, while decreasing trends were observed in those with SAND and ACS. Idiopathic degeneration was associated with AVCD, whereas extrinsic etiologies were related to SAND. Patients with intrinsic etiologies had a higher incidence of PPM implantation than those with extrinsic factors for TPM. (PACE 2010; 33:1475–1484)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.2010.02893.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Research works printed but not linked: 24

  1. 10.1056/NEJM195911052611904 · DOI
  2. 10.1161/01.CIR.0000035996.46455.09 · DOI · Paper page
  3. Vardas PE, 2007, Guidelines for cardiac pacing and cardiac resynchronization therapy. The Task Force for Cardiac Pacing and Cardiac Resynchronization Therapy of the European Society of Cardiology. Developed in Collaboration with de European Heart Rhythm Association, Europace, 9, 95
  4. Epstein AE, 2008, ACC/AHA/HRS 2008 Guidelines for Device‐Based Therapy of Cardiac Rhythm Abnormalities, Circulation, 117, e350
  5. Adan V, 2003, Diagnosis and treatment of sick sinus syndrome, Am Fam Physician, 67, 1725
  6. 10.1111/j.1540-8159.2008.01164.x · DOI · Paper page
  7. 10.1093/europace/eup346 · DOI
  8. Styliadis IH, 2008, Indications for permanent pacing and pacing mode prescription from 1989 to 2006. Experience of a single academic centre in Northern Greece, Hellenic J Cardiol, 49, 155
  9. 10.1016/S0140-6736(98)10279-9 · DOI · Paper page
  10. 10.1016/S0002-9149(99)00422-1 · DOI
  11. Ramamurthy S, 2007, Percutaneous coronary intervention for persistent complete heart block complicating inferior myocardial infarction, J Invasive Cardiol, 12, 372
  12. 10.1097/00005344-200004000-00007 · DOI
  13. 10.1161/01.CIR.0000121734.47409.AA · DOI · Paper page
  14. 10.1161/CIRCULATIONAHA.106.616011 · DOI · Paper page
  15. 10.1046/j.1540-8167.2002.00020.x · doi:10.1046/j.1540-8167.2002.00020.x
  16. 10.1161/01.CIR.102.15.1807 · DOI · Paper page
  17. 10.1161/01.CIR.0000090685.13169.07 · DOI · Paper page
  18. 10.1161/01.CIR.101.25.2975 · DOI
  19. 10.1093/cvr/8.2.153 · doi:10.1093/cvr/8.2.153
  20. 10.1093/ndt/gfm542 · DOI
  21. 10.1093/ndt/gfn445 · DOI
  22. Narula OS, 1984, Cardiac Arrhythmias: Electrophysiology, Diagnosis and Management, 57
  23. 10.1053/eupc.2001.0175 · DOI
  24. 10.1016/0002-8703(61)90664-0 · doi:10.1016/0002-8703(61)90664-0

Cited by

See all 15

Metadata

Authors
JOU, Y., HSU, H., TUAN, T., WANG, K., LIN, Y., LO, L., HU, Y., KONG, C., CHANG, S., & CHEN, S.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2010-10-14
Volume
33
Issue
12
Pages
1475-1484
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W1918415128
Cited by
15
References
3
FWCI
0.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Trends of Temporary Pacemaker Implant and Underlying Disease Substrate. https://app.cochat.ai/papers/10.1111/j.1540-8159.2010.02893.x
The paper
JOU, Y., HSU, H., TUAN, T., WANG, K., LIN, Y., LO, L., HU, Y., KONG, C., CHANG, S., & CHEN, S. (2010). Trends of Temporary Pacemaker Implant and Underlying Disease Substrate. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2010.02893.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.