Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 207

The DOI matches its Crossref record.

Reverse Remodeling of Sinus Node Function After Catheter Ablation of Atrial Fibrillation in Patients With Prolonged Sinus Pauses

Open access
Hocini, Mélèze, Sanders, Prashanthan, Deisenhofer, Isabel, Jaïs, Pierre, Hsu, Li-Fern, Scavée, Christophe, Weerasoriya, Rukshen, Raybaud, Florence, Macle, Laurent, Shah, Dipen C., Garrigue, Stéphane, Le Metayer, Philippe, Clémenty, Jacques, Haïssaguerre, Michel·2003·Circulation

Abstract

Background— Symptomatic prolonged sinus pauses on termination of atrial fibrillation (AF) are an indication for pacemaker implantation. We evaluated sinus node function and clinical outcome in patients with prolonged sinus pauses on termination of arrhythmia who underwent ablation of paroxysmal AF. Methods and Results— Twenty patients with paroxysmal AF and prolonged sinus pauses (≥3 seconds) on termination of AF underwent ablation between May 1995 and November 2002. Patients with sinus pauses independent of episodes of AF were excluded from the analysis. The procedure included pulmonary vein and linear atrial ablation. After ablation, sinus node function was assessed during the first week and at 1, 3, and 6 months, by 24-hour ambulatory monitoring to determine the mean heart rate and heart rate range, and by exercise testing to determine the maximal heart rate. Corrected sinus node recovery time was determined at the completion of ablation and at 24.0±11.3 months at 600 and 400 ms. After AF ablation, there was a significant improvement of sinus node function, with an increase in the mean heart rate ( P =0.001), maximal heart rate ( P <0.0001), and heart rate range ( P <0.0001). The corrected sinus node recovery time decreased in all patients evaluated at 600 ms ( P =0.016) and 400 ms ( P =0.019). At 26.0±17.6 months, 18 patients (85%) had no recurrence of AF (in the absence of medication), with no symptoms attributable to bradycardia or sinus pauses on ambulatory monitoring. Two patients had infrequent episodes of AF, 1 requiring pacemaker implantation. Conclusion— Prolonged sinus pauses after paroxysms of AF may result from depression of sinus node function that can be eliminated by curative ablation of AF. This is accompanied by improvement in parameters of sinus node function, suggesting reverse remodeling of the sinus node.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000090685.13169.07

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 207

Metadata

Authors
Hocini, M., Sanders, P., Deisenhofer, I., Jaïs, P., Hsu, L.-F., Scavée, C., Weerasoriya, R., Raybaud, F., Macle, L., Shah, D. C., Garrigue, S., Le Metayer, P., Clémenty, J., & Haïssaguerre, M.
Venue
Circulation
Published
2003-09-09
Volume
108
Issue
10
Pages
1172-1175
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2137675290
Cited by
207
References
0
FWCI
2.72
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reverse Remodeling of Sinus Node Function After Catheter Ablation of Atrial Fibrillation in Patients With Prolonged Sinus Pauses. https://app.cochat.ai/papers/10.1161/01.cir.0000090685.13169.07
The paper
Hocini, M., Sanders, P., Deisenhofer, I., Jaïs, P., Hsu, L.-F., Scavée, C., Weerasoriya, R., Raybaud, F., Macle, L., Shah, D. C., Garrigue, S., Le Metayer, P., Clémenty, J., & Haïssaguerre, M. (2003). Reverse Remodeling of Sinus Node Function After Catheter Ablation of Atrial Fibrillation in Patients With Prolonged Sinus Pauses. Circulation. https://doi.org/10.1161/01.cir.0000090685.13169.07

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.