CoChat

Electrical Remodeling of the Atria Associated With Paroxysmal and Chronic Atrial Flutter

Open access
Sparks, Paul B., Jayaprakash, Shenthar, Vohra, Jitendra K., Kalman, Jonathan M. · 2000 · Circulation
Cited by 126

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Background —Atrial electrical remodeling may be important for the initiation and perpetuation of atrial arrhythmias. Whether paroxysmal atrial flutter (AFL) and chronic AFL cause electrical remodeling of the atria has not been conclusively determined. Methods and Results —Before radiofrequency ablation of paroxysmal AFL, 15 patients in sinus rhythm were evaluated under autonomic blockade. Lateral right atrial (LRA) effective refractory periods (ERPs) at 600 and 450 ms were measured before and at 1-minute intervals for 10 minutes after spontaneous or pace termination of a 5- to 10-minute period of induced AFL. In 10 patients with chronic AFL, LRA, septal, and coronary sinus (CS) ERPs and corrected sinus node recovery times (cSNRTs) at 600 and 450 ms were measured under autonomic blockade 15 minutes, 30 minutes, and 3 weeks after termination of chronic AFL by ablation. In the paroxysmal AFL group, LRA ERPs decreased by 18% at 600 ms and 12% at 450 ms ( P <0.01) after induced AFL and recovered to baseline over ≈5 minutes. Atrial fibrillation developed during AFL in 3 patients and during ERP testing in 3 patients when refractoriness was at its nadir. In the chronic AFL group, LRA, septal, and CS ERPs at 3 weeks were significantly greater than at 15 and 30 minutes after termination of chronic AFL at both cycle lengths ( P <0.01). Three weeks after ablation, cSNRT decreased 35% at 600 ms ( P <0.05) and decreased 44% at 450 ms ( P <0.05). Both ERPs and cSNRTs measured 15 and 30 minutes after ablation of chronic AFL were not significantly different. Conclusions —Both paroxysmal AFL and chronic AFL cause reversible electrical remodeling of the atria but demonstrate different time courses of recovery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.102.15.1807

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 126

Metadata

Authors
Sparks, P. B., Jayaprakash, S., Vohra, J. K., & Kalman, J. M.
Venue
Circulation
Published
2000-10-10
Volume
102
Issue
15
Pages
1807-1813
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2157990041
Cited by
126
References
4
FWCI
5.17
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrical Remodeling of the Atria Associated With Paroxysmal and Chronic Atrial Flutter. https://app.cochat.ai/papers/10.1161/01.cir.102.15.1807
The paper
Sparks, P. B., Jayaprakash, S., Vohra, J. K., & Kalman, J. M. (2000). Electrical Remodeling of the Atria Associated With Paroxysmal and Chronic Atrial Flutter. Circulation. https://doi.org/10.1161/01.cir.102.15.1807

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.