Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 216

The DOI matches its Crossref record.

Gap Junction Protein Phenotypes of the Human Heart and Conduction System

DAVIS, LLOYD M., RODEFELD, MARK E., GREEN, KAREN, BEYER, ERIC C., SAFFITZ, JEFFREY E.·1995·Journal of Cardiovascular Electrophysiology

Abstract

Connexin Phenotypes in the Human Heart. Introduction: Gap junction channels are major determinants of intercellular resistance to current flow between cardiac myocytes. Alterations in gap junctions may contribute to development of arrhythmia substrates in patients. However, there is significant interspecies variation in the types and amounts of gap junction subunit proteins (connexins) expressed in disparate regions of mammalian hearts. To elucidate determinants of conduction properties in the human heart, we characterized connexin phenotypes of specific human cardiac tissues with different conduction properties. Methods and Results: The distribution and relative abundance of Cx37, Cx40, Cx43, Cx45, and Cx46 were studied immunohistochemically using monospecific antibodies and frozen sections of the sinoatrial node and adjacent atria, the AV node and His bundle, the bundle branches, and the left and right ventricular walls. Patterns of expression of these connexins in the human heart differed from those in previous animal studies. Sinus node gap junctions were small and sparse and contained Cx45 and apparently smaller amounts of Cx40 but no Cx43. AV node gap junctions were also small and contained mainly Cx45 and Cx40 hut, unlike the sinus node, also expressed Cx43. Atrial gap junctions were larger than nodal junctions and contained moderate amounts of Cx40, Cx43, and Cx45. Junctions in the bundle branches were the largest in size and contained abundant amounts of Cx40, Cx43, and Cx45. Gap junctions in ventricular myocardium contained mainly Cx43 and Cx45; only a very small amount of ventricular Cx40 was detected in subendocardial myocyte junctions and endothelial cells of small to medium sized intramural coronary arteries. Minimal Cx37 and Cx46 immunoreactivity was detected between occasional atrial or ventricular myocytes. Conclusions: The relative amounts of individual connexins and the number and size of gap junctions vary greatly in specific regions of the human heart with different conduction properties. These differences likely play a role in regulating cardiac conduction velocity. Differences in the connexin phenotypes of specific regions of the human heart and experimental animal hearts must he considered in future experimental or modeling studies of cardiac conduction.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.1995.tb00357.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 216

Metadata

Authors
DAVIS, L. M., RODEFELD, M. E., GREEN, K., BEYER, E. C., & SAFFITZ, J. E.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
1995-10
Volume
6
Issue
10
Pages
813-822
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2023443037
Cited by
216
References
0
FWCI
1.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Gap Junction Protein Phenotypes of the Human Heart and Conduction System. https://app.cochat.ai/papers/10.1111/j.1540-8167.1995.tb00357.x
The paper
DAVIS, L. M., RODEFELD, M. E., GREEN, K., BEYER, E. C., & SAFFITZ, J. E. (1995). Gap Junction Protein Phenotypes of the Human Heart and Conduction System. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.1995.tb00357.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.