CoChat

Electrocardiographic and Electrophysiologic Characterization of Atypical Atrial Flutter in Man: Use of Activation and Entrainment Mapping and Implications for Catheter Ablation

KALMAN, JONATHAN M., OLGIN, JEFFREY E., SAXON, LESLIE A., LEE, RANDALL J., SCHEINMAN, MELVIN M., LESH, MICHAEL D. · 1997 · Journal of Cardiovascular Electrophysiology
Cited by 139

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Atypical Atrial Flutter. Introduction: Although the circuit in typical counterclockwise atrial flutter has been clearly delineated, the mechanisms of “atypical atrial flutters” have been less well characterized. The purpose of this study was to investigate the ECG and electrophysiologic (EP) characteristics of atypical atrial flutter. Methods and Results: Thirty‐three patients with at least one form of atypical atrial flutter underwent EP evaluation with multipolar atrial activation and entrainment mapping. Nineteen patients with clockwise flutter had: (1) stereotypic ECG morphology; (2) same cycle length as counterclockwise flutter; (3) clockwise activation around the tricuspid annulus; (4) recording of discrete split potentials along the length of the crista terminalis, suggesting the presence of conduction block; (5) concealed entrainment from the low right atrial isthmus; (6) successful ablation in this isthmus. Twenty patients with atypical flutter not consistent with a clockwise mechanism (“true atypical flutter”) showed: (1) heterogeneous ECG morphology; (2) cycle length shorter than that of clockwise flutter; (3) frequent transitions from and to atrial fibrillation; (4) could be entrained in only six patients and, when accomplished, demonstrated surface fusion when entraining from the low right atrial isthmus. Conclusions: Atypical flutter falls into two broad categories. Clockwise flutter uses the same circuit with the same endocardial barriers as its counterclockwise counterpart and is best con sidered a form of typical flutter. True atypical flutter induced in the EP laboratory is a hetero geneous group of arrhythmias that are transitional to atrial fibrillation. Although it may superficially resemble clockwise or counterclockwise flutter based on the 12‐lead ECG alone, the distinction can be readily made from a combined evaluation including activation and entrainment mapping.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.1997.tb00775.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 139

Metadata

Authors
KALMAN, J. M., OLGIN, J. E., SAXON, L. A., LEE, R. J., SCHEINMAN, M. M., & LESH, M. D.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
1997-02
Volume
8
Issue
2
Pages
121-144
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2065363383
Cited by
139
References
1
FWCI
9.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrocardiographic and Electrophysiologic Characterization of Atypical Atrial Flutter in Man: Use of Activation and Entrainment Mapping and Implications for Catheter Ablation. https://app.cochat.ai/papers/10.1111/j.1540-8167.1997.tb00775.x
The paper
KALMAN, J. M., OLGIN, J. E., SAXON, L. A., LEE, R. J., SCHEINMAN, M. M., & LESH, M. D. (1997). Electrocardiographic and Electrophysiologic Characterization of Atypical Atrial Flutter in Man: Use of Activation and Entrainment Mapping and Implications for Catheter Ablation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.1997.tb00775.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.