Electrocardiographic and Electrophysiologic Characterization of Atypical Atrial Flutter in Man: Use of Activation and Entrainment Mapping and Implications for Catheter Ablation
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Atypical Atrial Flutter. Introduction: Although the circuit in typical counterclockwise atrial flutter has been clearly delineated, the mechanisms of “atypical atrial flutters” have been less well characterized. The purpose of this study was to investigate the ECG and electrophysiologic (EP) characteristics of atypical atrial flutter. Methods and Results: Thirty‐three patients with at least one form of atypical atrial flutter underwent EP evaluation with multipolar atrial activation and entrainment mapping. Nineteen patients with clockwise flutter had: (1) stereotypic ECG morphology; (2) same cycle length as counterclockwise flutter; (3) clockwise activation around the tricuspid annulus; (4) recording of discrete split potentials along the length of the crista terminalis, suggesting the presence of conduction block; (5) concealed entrainment from the low right atrial isthmus; (6) successful ablation in this isthmus. Twenty patients with atypical flutter not consistent with a clockwise mechanism (“true atypical flutter”) showed: (1) heterogeneous ECG morphology; (2) cycle length shorter than that of clockwise flutter; (3) frequent transitions from and to atrial fibrillation; (4) could be entrained in only six patients and, when accomplished, demonstrated surface fusion when entraining from the low right atrial isthmus. Conclusions: Atypical flutter falls into two broad categories. Clockwise flutter uses the same circuit with the same endocardial barriers as its counterclockwise counterpart and is best con sidered a form of typical flutter. True atypical flutter induced in the EP laboratory is a hetero geneous group of arrhythmias that are transitional to atrial fibrillation. Although it may superficially resemble clockwise or counterclockwise flutter based on the 12‐lead ECG alone, the distinction can be readily made from a combined evaluation including activation and entrainment mapping.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Olgin, J. E., Kalman, J. M., Fitzpatrick, A. P., & Lesh, M. D. (1995) · Circulation · doi:10.1161/01.cir.92.7.1839 · Cited by 500
Self-citation
Cited by
Blomström-Lundqvist, C., Scheinman, M. M., Aliot, E. M., Alpert, J. S., Calkins, H., Camm, A. J., Campbell, W. B., Haines, D. E., Kuck, K. H., Lerman, B. B., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.08.013 · Cited by 689
Self-citationSaoudi, N., Cosío, F., Waldo, A., Chen, S. A., Iesaka, Y., Lesh, M., Saksena, S., Salerno, J., & Schoels, W. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2658 · Cited by 464
Radio-Frequency Ablation as Treatment for Cardiac Arrhythmias
Morady, F. (1999) · New England Journal of Medicine · doi:10.1056/nejm199902183400707 · Cited by 281
Right Atrial Flutter Due to Lower Loop Reentry: Mechanism and Anatomic Substrates
Cheng, J., Cabeen, W. R., & Scheinman, M. M. (1999) · Circulation · doi:10.1161/01.cir.99.13.1700 · Cited by 152
Catheter ablation of atrial arrhythmias: state of the art
Lee, G., Sanders, P., & Kalman, J. M. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61463-9 · Cited by 151
Self-citationSurface electrocardiographic characteristics of right and left atrial flutter
Bochoeyer, A., Yang, Y., Cheng, J., Lee, R. J., Keung, E. C., Marrouche, N. F., Natale, A., & Scheinman, M. M. (2003) · Circulation · doi:10.1161/01.cir.0000079140.35025.1e · Cited by 123
Self-citationFriedman, P. A., Luria, D., Fenton, A. M., Munger, T. M., Jahangir, A., Shen, W. K., Rea, R. F., Stanton, M. S., Hammill, S. C., & Packer, D. L. (2000) · Circulation · doi:10.1161/01.cir.101.13.1568 · Cited by 117
Risk of thromboembolism in chronic atrial flutter
Wood, K. A., Eisenberg, S. J., Kalman, J. M., Drew, B. J., Saxon, L. A., Lee, R. J., Lesh, M. D., & Scheinman, M. M. (1997) · The American Journal of Cardiology · doi:10.1016/s0002-9149(97)00044-1 · Cited by 108
Self-citationAtypical atrial flutter originating in the right atrial free wall
Kall, J. G., Rubenstein, D. S., Kopp, D. E., Burke, M. C., Verdino, R. J., Lin, A. C., Johnson, C. T., Cooke, P. A., Wang, Z. G., Fumo, M., et al. (2000) · Circulation · doi:10.1161/01.cir.101.3.270 · Cited by 105
Variable electrocardiographic characteristics of isthmus-dependent atrial flutter
Milliez, P., Richardson, A. W., Obioha-Ngwu, O., Zimetbaum, P. J., Papageorgiou, P., & Josephson, M. E. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02070-3 · Cited by 68
Metadata
- Authors
- KALMAN, J. M., OLGIN, J. E., SAXON, L. A., LEE, R. J., SCHEINMAN, M. M., & LESH, M. D.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 1997-02
- Volume
- 8
- Issue
- 2
- Pages
- 121-144
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2065363383
- Cited by
- 139
- References
- 1
- FWCI
- 9.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.