The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Catheter Ablation of Long‐Lasting Persistent Atrial Fibrillation: Clinical Outcome and Mechanisms of Subsequent Arrhythmias
Abstract
Background: Catheter ablation of atrial fibrillation (AF) is challenging in patients with long‐standing persistent AF. The clinical outcome and subsequent arrhythmia recurrence after using an ablation method targeting multiple left atrial sites with the aim of achieving acute AF termination has not been characterized. Methods: Sixty patients (mean age: 53 ± 9 years) with persistent AF (mean duration: 17 ± 27 months) were prospectively followed after catheter ablation. Catheter ablation targeting the following sites was performed in a random sequence: (i) electrical isolation of all pulmonary veins (PV); (ii) disconnection of other thoracic veins; (iii) atrial ablation at sites possessing complex electrical activity, activation gradients, or short cycle lengths. Finally, linear ablation of the LA roof and mitral isthmus was performed if sinus rhythm was not restored following energy delivery to the above sites. At 1, 3, 6, and 12 months after ablation, patients underwent clinical review and 24‐hour ambulatory ECG monitoring to identify asymptomatic arrhythmia. Repeat mapping and catheter ablation was performed in any patient experiencing recurrent atrial tachycardia (AT). Clinical success was defined as the absence of any sustained atrial arrhythmia. Results: AF terminated during ablation in 52 patients (87%). The fluoroscopy and procedural durations were 84 ± 30 minutes and 264 ± 77 minutes, respectively. Three months after ablation, sustained ATs were documented in 24 patients (associated with AF in 2). Mapping in 23 patients showed a single AT in 7 while multiple ATs were observed in 16. Macroreentry was confirmed to be due to gaps in the ablation lines, while focal ATs originated from discrete sites or isthmuses near the left atrial appendage, coronary sinus, pulmonary veins, or fossa ovalis; these sites were similar to those at which the greatest impact was observed on the fibrillatory process during the initial ablation procedure. After repeat ablation, at 11 ± 6 months of follow‐up, 57 patients (95%) were in sinus rhythm and 3 developed recurrent AF or AT. All patients in sinus rhythm demonstrated improved exercise capacity and all but 2 had evidence of atrial transport as assessed by Doppler echocardiography (mitral A wave velocity 34 ± 17 cm/sec) by 6 months. Conclusion: Catheter ablation of long‐lasting persistent AF associated with acute AF termination achieves medium to long‐term restoration and maintenance of sinus rhythm in 95% of patients. Arrhythmia recurrence in the majority of patients is AT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary Veins
Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., Garrigue, S., Le Mouroux, A., Le Métayer, P., & Clémenty, J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199809033391003 · Cited by 7,975
Self-citationA comparison of rate control and rhythm control in patients with atrial fibrillation
(2002) · New England Journal of Medicine · doi:10.1056/nejmoa021328 · Cited by 4,405
Van Gelder, I. C., Hagens, V. E., Bosker, H. A., Kingma, J. H., Kamp, O., Kingma, T., Said, S. A., Darmanata, J. I., Timmermans, A. J. M., Tijssen, J. G. P., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa021375 · Cited by 2,359
Nademanee, K., McKenzie, J., Kosar, E., Schwab, M., Sunsaneewitayakul, B., Vasavakul, T., Khunnawat, C., & Ngarmukos, T. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.12.054 · Cited by 2,002
Cleland, J. (2003) · European Heart Journal · doi:10.1016/s0195-668x(02)00823-0 · Cited by 1,549
Chen, S.-A., Hsieh, M.-H., Tai, C.-T., Tsai, C.-F., Prakash, V. S., Yu, W.-C., Hsu, T.-L., Ding, Y.-A., & Chang, M.-S. (1999) · Circulation · doi:10.1161/01.cir.100.18.1879 · Cited by 1,446
The AFFIRM Investigators (2004) · Circulation · doi:10.1161/01.cir.0000121736.16643.11 · Cited by 1,206
Hohnloser, S. H., Kuck, K.-H., & Lilienthal, J. (2000) · The Lancet · doi:10.1016/s0140-6736(00)03230-x · Cited by 1,134
Pulmonary Vein Isolation for Paroxysmal and Persistent Atrial Fibrillation
Oral, H., Knight, B. P., Tada, H., Özaydın, M., Chugh, A., Hassan, S., Scharf, C., Lai, S. W. K., Greenstein, R., Pelosi, F., et al. (2002) · Circulation · doi:10.1161/hc0902.104712 · Cited by 1,112
Morillo, C. A., Klein, G. J., Jones, D. L., & Guiraudon, C. M. (1995) · Circulation · doi:10.1161/01.cir.91.5.1588 · Cited by 1,037
Cited by
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström-Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P. E., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 9,971
2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.03.022 · Cited by 2,955
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000040 · Cited by 2,056
Metadata
- Authors
- HAÏSSAGUERRE, M., HOCINI, M., SANDERS, P., SACHER, F., ROTTER, M., TAKAHASHI, Y., ROSTOCK, T., HSU, L., BORDACHAR, P., REUTER, S., ROUDAUT, R., CLÉMENTY, J., & JAÏS, P.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2005-09-28
- Volume
- 16
- Issue
- 11
- Pages
- 1138-1147
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2033170044
- Cited by
- 755
- References
- 41
- FWCI
- 35.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Catheter Ablation of Long‐Lasting Persistent Atrial Fibrillation: Clinical Outcome and Mechanisms of Subsequent Arrhythmias. https://app.cochat.ai/papers/10.1111/j.1540-8167.2005.00308.x
- The paper
- HAÏSSAGUERRE, M., HOCINI, M., SANDERS, P., SACHER, F., ROTTER, M., TAKAHASHI, Y., ROSTOCK, T., HSU, L., BORDACHAR, P., REUTER, S., ROUDAUT, R., CLÉMENTY, J., & JAÏS, P. (2005). Catheter Ablation of Long‐Lasting Persistent Atrial Fibrillation: Clinical Outcome and Mechanisms of Subsequent Arrhythmias. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.2005.00308.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.