Regression Analysis Between Heart Rate Variability and Baroreflex‐Related Vagus Nerve Activity in Rats
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Introduction: Many previous studies have suggested that the high‐frequency (HF) power of the heart rate variability may represent cardiac vagal activity although direct evidence of a correlation between the HF and vagal neuronal activity is still lacking. In the present study, we performed a regression analysis of the HF and vagal neurograms. Methods and Results: Experiments were carried out on adult male Sprague‐Dawley rats anesthetized with a continuous infusion of pentobarbital sodium. The baroreflex‐related vagus neuronal activities were obtained by nerve or single‐fiber recordings. The transient baroreflex response was employed to alter vagus neuronal activities using a bolus injection of phenylephrine (PE). On‐line power spectral analysis of the heart rate and a vagal neurogram was performed during the acute baroreflex response. During the test period, systemic arterial pressure immediately increased in response to the PE injection, after which the R–R interval (RR), HF (0.6–2.4 Hz), and vagus nerve and unit activities all dramatically increased. Both nerve and unit activities exhibited good correlations (r ≥ 0.7 in all nerve recordings and r ≥ 0.6 in 91% of single‐fiber recordings) with the HF. There were insignificant differences between the right‐ and left‐side baroreflex‐related vagus nerve recordings. Conclusion: Our present study provides a direct linkage between the HF and vagus neuronal electrical activity in anesthetized rats.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Akselrod, S., Gordon, D., Ubel, F. A., Shannon, D. C., Berger, A. C., & Cohen, R. J. (1981) · Science · doi:10.1126/science.6166045 · Cited by 5,079
Cardiovascular neural regulation explored in the frequency domain.
Malliani, A., Pagani, M., Lombardi, F., & Cerutti, S. (1991) · Circulation · doi:10.1161/01.cir.84.2.482 · Cited by 3,569
Cited by
Farmer, A. D., Strzelczyk, A., Finisguerra, A., Gourine, A. V., Gharabaghi, A., Hasan, A., Burger, A. M., Jaramillo, A. M., Mertens, A., Majid, A., et al. (2021) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2020.568051 · Cited by 355
Circadian Variation of Heart Rate Variability Across Sleep Stages
Boudreau, P., Yeh, W.-H., Dumont, G. A., & Boivin, D. B. (2013) · Sleep · doi:10.5665/sleep.3230 · Cited by 235
Brosschot, J. F., Verkuil, B., & Thayer, J. F. (2017) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2016.07.019 · Cited by 178
“For example, it has been shown in a rodent model that high frequency HRV correlates 0.88 with vagus nerve activity (Kuo et al., 2005).”
BackgroundInfluentialYoo, H. J., Thayer, J. F., Greening, S., Lee, T.-H., Ponzio, A., Min, J., Sakaki, M., Nga, L., Mather, M., & Koenig, J. (2018) · Brain Structure and Function · doi:10.1007/s00429-017-1519-7 · Cited by 94
Williams, P. G., Cribbet, M. R., Tinajero, R., Rau, H. K., Thayer, J. F., & Suchy, Y. (2019) · Biological Psychology · doi:10.1016/j.biopsycho.2019.107772 · Cited by 41
Metadata
- Authors
- KUO, T. B. J., LAI, C. J., HUANG, Y., & YANG, C. C. H.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2005-04-12
- Volume
- 16
- Issue
- 8
- Pages
- 864-869
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2143401920
- Cited by
- 135
- References
- 3
- FWCI
- 1.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.