The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Catheter Ablation of Atrial Fibrillation in Patients with Diabetes Mellitus Type 2: Results from a Randomized Study Comparing Pulmonary Vein Isolation Versus Antiarrhythmic Drug Therapy
Abstract
INTRODUCTION: Atrial fibrillation (AF) and diabetes mellitus type 2 (DM2) often coexist; however, a small number of patients with DM2 undergoing catheter ablation (CA) of AF have been included in previous studies. The aim of this study was to evaluate safety and efficacy of ablation therapy in DM2 patients with drug refractory AF. METHODS AND RESULTS: From January 2005 to September 2006, 70 patients with a diagnosis of DM2 and paroxysmal (n = 29) or persistent (n = 41) AF were randomized to receive either pulmonary vein isolation or a new antiarrhythmic drug treatment (ADT) with a 1-year follow-up. The primary endpoint was the time to first AF recurrence. By Kaplan-Meier analysis, at the end of follow-up, 42.9% of patients in the ADT group and 80% of patients who received a single ablation procedure and were without medications were free of AF (P = 0.001). In the ablation group, a significant improvement in quality-of-life (QoL) scores as compared with ADT group was observed. Six patients in the ADT group (17.1%) developed significant adverse drug effects. Hospitalization rate during follow-up was higher in the ADT group (P = 0.01). The only complication attributable to ablation was one significant access-site hematoma. CONCLUSION: In patients with DM2, CA of AF provides significant clinical benefits over the ADT and appears to be a reasonable approach regarding feasibility, effectiveness, and low procedural risk.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Most patients require more than one procedure to achieve symptom control.713,726,728”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [726]
Citations
Cites
McHorney, C. A., Ware, J. E., Rachel Lu, J. F., & Sherbourne, C. D. (1994) · Medical Care · doi:10.1097/00005650-199401000-00004 · Cited by 4,458
A comparison of rate control and rhythm control in patients with atrial fibrillation
(2002) · New England Journal of Medicine · doi:10.1056/nejmoa021328 · Cited by 4,405
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
Gelder, I. C. V., Hagens, V. E., Bosker, H. A., Kingma, J. H., Otto Kamp, B., Kingma, T., Said, S. A., Darmanata, J. I., Timmermans, A. J. M., Tijssen, J. G. P., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa021375 · Cited by 2,355
Epidemiologic Features of Chronic Atrial Fibrillation
Kannel, W. B., Abbott, R. D., Savage, D. D., & McNamara, P. M. (1982) · New England Journal of Medicine · doi:10.1056/nejm198204293061703 · Cited by 2,304
Wazni, O. M., Marrouche, N. F., Martin, D. O., Verma, A., Bhargava, M., Saliba, W., Bash, D., Schweikert, R., Brachmann, J., Gunther, J., et al. (2005) · JAMA · doi:10.1001/jama.293.21.2634 · Cited by 1,121
Catheter Ablation for Atrial Fibrillation in Congestive Heart Failure
Hsu, L., Jaı̈s, P., Sanders, P., Garrigue, S., Hocini, M., Sacher, F., Takahashi, Y., Rotter, M., Pasquié, J., Scavée, C., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa041018 · Cited by 890
Pappone, C., Augello, G., Sala, S., Gugliotta, F., Vicedomini, G., Gulletta, S., Paglino, G., Mazzone, P., Sora, N., Greiss, I., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.08.037 · Cited by 685
Authors Task Force Members, Fuster, V., Rydén, L., Cannom, D. S., Crijns, H. J. G. M., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Heuzey, J. L., Kay, G. N., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl176 · Cited by 646
Characterization of Different Subsets of Atrial Fibrillation in General Practice in France
Lévy, S., Maarek, M., Coumel, P., Guize, L., Lekieffre, J., Medvedowsky, J. L., & Sebaoun, A. (1999) · Circulation · doi:10.1161/01.cir.99.23.3028 · Cited by 580
Cited by
Sorted by citations
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström‐Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 10,550
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P. F., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castellà, M., Diener, H., Heidbüchel, H., Hendriks, J., et al. (2016) · EP Europace · doi:10.1093/europace/euw295 · Cited by 6,438
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw210 · Cited by 6,418
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A. M., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2023) · Circulation · doi:10.1161/cir.0000000000001193 · Cited by 3,145
2023 ESC guidelines for the management of cardiomyopathies
Arbelo, E., Protonotarios, A., Gimeno, J. R., Arbustini, E., Barriales-Villa, R., Basso, C., Bezzina, C. R., Biagini, E., Blom, N. A., de Boer, R. A., et al. (2023) · European Heart Journal · doi:10.1093/eurheartj/ehad194 · Cited by 2,844
Metadata
- Authors
- FORLEO, G. B., MANTICA, M., DE LUCA, L., LEO, R., SANTINI, L., PANIGADA, S., DE SANCTIS, V., PAPPALARDO, A., LAURENZI, F., AVELLA, A., CASELLA, M., RUSSO, A. D., ROMEO, F., PELARGONIO, G., & TONDO, C.
- Affiliations
- Università Cattolica del Sacro Cuore (IT)
- Istituto Clinico Sant'Ambrogio (IT)
- University of Rome Tor Vergata (IT)
- Corresponding author
- TONDO, CLAUDIO
- ORCID
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2008-12-29
- Volume
- 20
- Issue
- 1
- Pages
- 22-28
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2105908026
- Cited by
- 165
- References
- 28
- Citations by year
- 2026: 5 · 2025: 6 · 2024: 6 · 2023: 10 · 2022: 7 · 2021: 8 · 2020: 15 · 2019: 5 · 2018: 12 · 2017: 11 · 2016: 11 · 2015: 11 · 2014: 11 · 2013: 11 · 2012: 14
- FWCI
- 5.09
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Cardiovascular Electrophysiology (publishedVersion)
- PubMed (publishedVersion)
- Cineca Institutional Research Information System (Tor Vergata University) (submittedVersion)
- Università Politecnica delle Marche (Università Politecnica delle Marche) (submittedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- atrial fibrillation, type 2 diabetes, catheter ablation, pulmonary vein isolation, antiarrhythmic drugs, drug-refractory atrial fibrillation, atrial fibrillation recurrence, quality of life, adverse drug reactions, hospitalization, access site hematoma
- MeSH terms
- Anti-Arrhythmia Agents, Atrial Fibrillation, Diabetes Mellitus, Type 2, Female, Heart Conduction System, Humans, Italy, Male, Middle Aged, Pulmonary Veins, Treatment Outcome, Catheter Ablation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review