Additional Diagnostic Value of Very Prolonged Observation by Implantable Loop Recorder in Patients with Unexplained Syncope
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Long‐Term Observation with ILR. Introduction: In the literature, the average diagnostic yield of the implantable loop recorder (ILR) is reported to be 35% over an observation period generally less than 18 months. The aim of this study was to evaluate the diagnostic value of ILR during very prolonged observation. Methods and Results: Consecutive patients who had received one or more (in the case of battery exhaustion before diagnosis) ILR (Reveal/plus/DX, Medtronic Inc.) from 2001 to 2010 were included. The diagnostic ECG was classified according to the ISSUE classification. We analyzed 157 patients (87 males, 69 ± 14 years): 70 of these were followed up for ≥18 months. The estimated cumulative diagnostic rates were 30%, 43%, 52%, and 80% at 1, 2, 3, and 4 years, respectively; 26% of diagnoses were made after 18 months. The diagnostic yield was independent of structural heart disease, bundle branch block, number of syncopes, age, and gender; the median time to diagnosis of ISSUE type 1 patients was shorter than that of the others (4 [2;10] vs. 16 [6;23] months; P = 0.003). During the observation period, 3 patients (1.9%) died and none suffered arrhythmic death. Conclusions: Prolonging observation up to 4 years increased the diagnostic value of ILR in syncopal patients and was safe. A quarter of patients diagnosed needed more than 18 months of follow‐up. As consequence, when a strategy of prolonging monitoring is chosen, monitoring should be maintained even for several years until diagnosis is established. (J Cardiovasc Electrophysiol, Vol. 23, pp. 67‐71, January 2012)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Developed in collaboration with, European Heart Rhythm Association (EHRA), Heart Failure Association (HFA), and Heart Rhythm Society (HRS), societies, E. B. T. F., European Society of Emergency Medicine (EuSEM), European Federation of Internal Medicine (EFIM), European Union Geriatric Medicine Society (EUGMS), American Geriatrics Society (AGS), European Neurological Society (ENS), et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp298 · Cited by 2,040
Self-citationMechanism of Syncope in Patients With Isolated Syncope and in Patients With Tilt-Positive Syncope
Moya, A., Brignole, M., Menozzi, C., Garcia-Civera, R., Tognarini, S., Mont, L., Botto, G., Giada, F., Cornacchia, D., & on behalf of the International Study on Syncope of Uncertain Etiology (ISSUE) Investigators (2001) · Circulation · doi:10.1161/hc3601.095708 · Cited by 378
Self-citationBrignole, M., Sutton, R., Menozzi, C., Garcia-Civera, R., Moya, A., Wieling, W., Andresen, D., Benditt, D. G., & Vardas, P. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi842 · Cited by 376
Self-citationIndications for the use of diagnostic implantable and external ECG loop recorders
Task Force members, Brignole, M., Vardas, P., Hoffman, E., Huikuri, H., Moya, A., Ricci, R., Sulke, N., Wieling, W., EHRA Scientific Documents Committee, et al. (2009) · Europace · doi:10.1093/europace/eup097 · Cited by 362 · cited 2×
“The diagnostic yield was independent of structural heart disease, bundle branch block, number of syncopes, age, and gender; the median time to diagnosis of ISSUE type 1 patients was shorter than that of the others (4 [2;10] vs.”
BackgroundSelf-citationUse of an Extended Monitoring Strategy in Patients With Problematic Syncope
Krahn, A. D., Klein, G. J., Yee, R., Takle-Newhouse, T., & Norris, C. (1999) · Circulation · doi:10.1161/01.cir.99.3.406 · Cited by 360
Mechanism of syncope in patients with bundle branch block and negative electrophysiological test
Brignole, M., Menozzi, C., Moya, A., Garcia-Civera, R., Mont, L., Alvarez, M., Errazquin, F., Beiras, J., Bottoni, N., Donateo, P., et al. (2001) · Circulation · doi:10.1161/hc4201.097837 · Cited by 328
Self-citationEdvardsson, N., Frykman, V., van Mechelen, R., Mitro, P., Mohii-Oskarsson, A., Pasquie, J.-L., Ramanna, H., Schwertfeger, F., Ventura, R., Voulgaraki, D., et al. (2011) · Europace · doi:10.1093/europace/euq418 · Cited by 250
The clinical impact of implantable loop recorders in patients with syncope
Farwell, D. J., Freemantle, N., & Sulke, N. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi602 · Cited by 219
Mechanism of syncope in patients with heart disease and negative electrophysiologic test
Menozzi, C., Brignole, M., Garcia-Civera, R., Moya, A., Botto, G., Tercedor, L., Migliorini, R., & Navarro, X. (2002) · Circulation · doi:10.1161/01.cir.0000018125.31973.87 · Cited by 204
An Implantable Loop Recorder Study of Highly Symptomatic Vasovagal Patients
Deharo, J.-C., Jego, C., Lanteaume, A., & Djiane, P. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.09.043 · Cited by 110
Cited by
2018 ESC Guidelines for the diagnosis and management of syncope
Brignole, M., Moya, A., de Lange, F. J., Deharo, J.-C., Elliott, P. M., Fanciulli, A., Fedorowski, A., Furlan, R., Kenny, R. A., Martín, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy037 · Cited by 1,951
Self-citation2018 ESC Guidelines for the diagnosis and management of syncope
Brignole, M., Moya, A., De Lange, F. J., Deharo, J.-C., Elliott, P. M., Fanciulli, A., Fedorowski, A., Furlan, R., Kenny, R. A., Martiın, A., et al. (2018) · Kardiologia Polska · doi:10.5603/kp.2018.0161 · Cited by 476
Self-citationBrignole, M., Menozzi, C., Moya, A., Andresen, D., Blanc, J. J., Krahn, A. D., Wieling, W., Beiras, X., Deharo, J. C., Russo, V., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.082313 · Cited by 437
Self-citationThe Reveal LINQ insertable cardiac monitor
Tomson, T. T., & Passman, R. (2015) · Expert Review of Medical Devices · doi:10.1586/17434440.2014.953059 · Cited by 72
Ungar, A., Sgobino, P., Russo, V., Vitale, E., Sutton, R., Melissano, D., Beiras, X., Bottoni, N., Ebert, H. H., Gulizia, M., et al. (2013) · Heart · doi:10.1136/heartjnl-2013-304399 · Cited by 58
Self-citation
Metadata
- Authors
- FURUKAWA, T., MAGGI, R., BERTOLONE, C., FONTANA, D., & BRIGNOLE, M.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2011-07-21
- Volume
- 23
- Issue
- 1
- Pages
- 67-71
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W1987758043
- Cited by
- 77
- References
- 11
- FWCI
- 6.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Additional Diagnostic Value of Very Prolonged Observation by Implantable Loop Recorder in Patients with Unexplained Syncope. https://app.cochat.ai/papers/10.1111/j.1540-8167.2011.02133.x
- The paper
- FURUKAWA, T., MAGGI, R., BERTOLONE, C., FONTANA, D., & BRIGNOLE, M. (2012). Additional Diagnostic Value of Very Prolonged Observation by Implantable Loop Recorder in Patients with Unexplained Syncope. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.2011.02133.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.