CoChat

Diagnosis of neurally mediated syncope at initial evaluation and with tilt table testing compared with that revealed by prolonged ECG monitoring. An analysis from the Third International Study on Syncope of Uncertain Etiology (ISSUE-3)

Open access
Ungar, Andrea, Sgobino, Paolo, Russo, Vitantonio, Vitale, Elena, Sutton, Richard, Melissano, Donato, Beiras, Xulio, Bottoni, Nicola, Ebert, Hans H, Gulizia, Michele, Jorfida, Marcella, Moya, Angel, Andresen, Dietrich, Grovale, Nicoletta, Brignole, Michele, on behalf of the International Study on Syncope of Uncertain Etiology 3 (ISSUE-3) Investigators · 2013 · Heart

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: According to the guidelines of the European Society of Cardiology, a presumed diagnosis of neurally mediated syncope (NMS) can be made when patients have a consistent history and competing diagnoses are excluded. In the present study, we compared the initial diagnosis of NMS by means of implantable loop recorder (ILR) documentation. METHODS: In this prospective multicentre observational study which involved 51 hospitals in nine countries in Europe and Canada, 504 NMS patients ≥40 years, who had suffered ≥3 syncopal episodes in the previous 2 years received an ILR and were followed up for a mean of 15±11 months. RESULTS: ILR recorded a spontaneous syncope in 187 cases, with an estimated diagnostic yield of 47% at 3 years. ILR findings were consistent with the initial diagnosis of presumed NMS in 162 (87%) patients whereas did not confirm NMS in another 25 (13%), who had an intrinsic cardiac arrhythmic cause (atrial tachyarrhythmias (#6), long pause on termination of tachyarrhythmia (#8), persistent bradycardia (#3), ventricular tachycardia (#4)) or a non-arrhythmic loss of consciousness (non-syncopal (#3), orthostatic hypotension (#1)). No clinical baseline feature was able to predict an intrinsic cardiac cause with the exception of more frequent non-syncopal atrial tachyarrhythmias on clinical history, which were present in 38% of cardiac versus 5% of NMS patients (p=0.001). Tilt table testing (TT) was positive in 76/136 (56%) presumed NMS and in 9/21 (43%) non-NMS patients (p=0.35); an asystolic response was present in 28/136 (21%) NMS and in 0/21 (0%) non-NMS patients (p=0.03). CONCLUSIONS: ILR findings showed results other than NMS in a small, although non-negligible, number of patients older than 40 years. TT was unable to discriminate between presumed NMS and non-NMS with the exception of an asystolic response which was highly specific.

Overview

Integrity signals

Registry

Crossref · 10.1136/heartjnl-2013-304399

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 32 references

Cited by

See all 58

Metadata

Authors
Ungar, A., Sgobino, P., Russo, V., Vitale, E., Sutton, R., Melissano, D., Beiras, X., Bottoni, N., Ebert, H. H., Gulizia, M., Jorfida, M., Moya, A., Andresen, D., Grovale, N., Brignole, M., & on behalf of the International Study on Syncope of Uncertain Etiology 3 (ISSUE-3) Investigators
Affiliations
  • Azienda Ospedaliero-Universitaria Careggi (IT)
  • Ospedale di Bolzano (IT)
  • Departments of Cardiology, Ospedale di Manduria, Taranto, Italy
  • Azienda Ospedaliera Nazionale SS. Antonio e Biagio e Cesare Arrigo (IT)
  • Imperial College Healthcare NHS Trust (GB)
  • Departments of Cardiology, Presidio Ospedaliero di Casarano, Lecce, Italy
  • Departments of Cardiology, Hospital Xeral de Vigo, Vigo, Spain
  • Santa Maria Nuova Hospital (IT)
  • Departments of Cardiology, Kardiologische Gemeinschaftspraxis, Riesa, Germany
  • Ospedale Garibaldi (IT)
  • Departments of Cardiology, Ospedale S. Giovanni Battista Le Molinette, Torino, Italy
  • Departments of Cardiology, Hospital Universitario Vall d'Hebron, Barcelona, Spain
  • Vivantes Klinikum (DE)
  • Medtronic (Italy) (IT)
  • Presidio Ospedaliero (IT)
Corresponding author
Brignole, Michele
Venue
Heart
Publisher
BMJ
Published
2013-10-23
Volume
99
Issue
24
Pages
1825-1831
ISSN
  • 1355-6037 (ISSN-L)
  • 1468-201X
OpenAlex
W2141860003
Cited by
58
References
32
Citations by year
2025: 2 · 2024: 5 · 2023: 5 · 2022: 6 · 2021: 5 · 2020: 6 · 2019: 3 · 2018: 4 · 2017: 5 · 2016: 6 · 2015: 4 · 2014: 7
FWCI
5.58
Type
journal article
Language
en
Open access
Licence
other-oa
Locations
  • Heart (publishedVersion)
  • PubMed (publishedVersion)
  • LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) (submittedVersion, other-oa)
  • Florence Research (University of Florence) (submittedVersion)
  • RUNA. Repositorio Institucional del Sergas (Servicio Gallego de Salud (SERGAS)) (submittedVersion, other-oa)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
Keywords
neurally mediated syncope, implantable loop recorder, tilt table test, diagnostic yield, cardiac arrhythmias, atrial tachyarrhythmia, orthostatic hypotension, loss of consciousness
MeSH terms
Aged, Cardiac Pacing, Artificial, Diagnosis, Differential, Female, Heart Conduction System, Humans, Male, Middle Aged, Prospective Studies, Syncope, Electrocardiography, Ambulatory, Tilt-Table Test

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnosis of neurally mediated syncope at initial evaluation and with tilt table testing compared with that revealed by prolonged ECG monitoring. An analysis from the Third International Study on Syncope of Uncertain Etiology (ISSUE-3). https://app.cochat.ai/papers/10.1136/heartjnl-2013-304399
The paper
Ungar, A., Sgobino, P., Russo, V., Vitale, E., Sutton, R., Melissano, D., Beiras, X., Bottoni, N., Ebert, H. H., Gulizia, M., Jorfida, M., Moya, A., Andresen, D., Grovale, N., Brignole, M., & on behalf of the International Study on Syncope of Uncertain Etiology 3 (ISSUE-3) Investigators. (2013). Diagnosis of neurally mediated syncope at initial evaluation and with tilt table testing compared with that revealed by prolonged ECG monitoring. An analysis from the Third International Study on Syncope of Uncertain Etiology (ISSUE-3). Heart. https://doi.org/10.1136/heartjnl-2013-304399

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.