Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 211

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Head‐To‐Head Comparison of Arrhythmia Discrimination Performance of Subcutaneous and Transvenous ICD Arrhythmia Detection Algorithms: The START Study

GOLD, MICHAEL R., THEUNS, DOMINIC A., KNIGHT, BRADLEY P., STURDIVANT, J. LACY, SANGHERA, RICK, ELLENBOGEN, KENNETH A., WOOD, MARK A., BURKE, MARTIN C. · 2012 · Journal of Cardiovascular Electrophysiology

Abstract

Arrhythmia Detection with S‐ICD Versus Transvenous ICDs. Background: The development of a totally subcutaneous implantable defibrillator (S‐ICD) system requires a new approach for arrhythmia detection. To evaluate arrhythmia discrimination of one such system, the Subcutaneous versus Transvenous Arrhythmia Recognition Testing (START) study was designed as a prospective, multicenter trial comparing simulated sensing performances of the S‐ICD system with single‐ (SC‐TV) and dual‐chamber transvenous (DC‐TV) implantable cardioverter‐defibrillator (ICD) systems. Methods: At ICD implantation, induced ventricular and atrial arrhythmias were recorded simultaneously in transvenous (right ventricular [RV]→superior vena cava [SVC]+ Coil) and cutaneous electrode configurations. Recorded signals of ventricular (n = 46) and atrial arrhythmias (n = 50) with ventricular rates >170 bpm from 64 patients were used to compare detection performance of the S‐ICD system with TV‐ICD systems from 3 manufacturers. Appropriate detection of ventricular tachyarrhythmias was assessed with devices programmed in single‐zone (rate ≥170 bpm) and dual‐zone configurations (ventricular fibrillation ≥240 bpm; ventricular tachycardia ≥170 bpm). S‐ICD specificity performance for supraventricular arrhythmias was compared to single‐ and dual‐chamber devices in a dual‐zone configuration. Results: Appropriate detection of ventricular tachyarrhythmias for subcutaneous and TV devices in single‐ and dual‐zone configurations was 100% and >99%, respectively. Specificity for supraventricular arrhythmias was significantly better for the S‐ICD system compared to 2 of 3 TV systems, as well as the composite of TV devices (98.0%[S‐ICD] vs 76.7%[SC‐TV range: 64.0–92.0%] vs 68.0%[DC‐TV range: 32.7–89.8%; P < 0.001]). Conclusion: Appropriate ventricular arrhythmia detection is excellent for all ICD systems evaluated; however, specificity of supraventricular arrhythmia discrimination by the S‐ICD system is better than discrimination by 2 of 3 TV systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.2011.02199.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 211

Metadata

Authors
GOLD, M. R., THEUNS, D. A., KNIGHT, B. P., STURDIVANT, J. L., SANGHERA, R., ELLENBOGEN, K. A., WOOD, M. A., & BURKE, M. C.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2011-10-28
Volume
23
Issue
4
Pages
359-366
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W1971203831
Cited by
211
References
1
FWCI
12.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.